Influence of visual force feedback on tissue handling in minimally invasive surgery

被引:30
|
作者
Rodrigues, S. P. [1 ]
Horeman, T. [2 ]
Sam, P. [1 ]
Dankelman, J. [2 ]
van den Dobbelsteen, J. J. [2 ]
Jansen, F. -W. [1 ,2 ]
机构
[1] Leiden Univ, Med Ctr, Dept Gynaecol, NL-2300 RC Leiden, Netherlands
[2] Delft Univ Technol, Dept Biomech Engn, Delft, Netherlands
关键词
D O I
10.1002/bjs.9669
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundForce feedback might improve surgical performance during minimally invasive surgery. This study sought to determine whether training with force feedback shortened the tissue-handling learning curve, and examined the influence of real-time visual feedback compared with postprocessing feedback. MethodsMedical students without experience of minimally invasive surgery were randomized into three groups: real-time force feedback, postprocessing force feedback and no force feedback (control). All performed eight suturing tasks consecutively, of which the first and eighth were the premeasurement and postmeasurement tasks respectively (no feedback). Depending on randomization, either form of feedback was given during the second to seventh task. Time, mean force non-zero and maximum force were measured with a force sensor. Results of the groups were compared with one-way ANOVA, and intragroup improvement using a paired-samples t test. ResultsA total of 72 students took part. Both intervention groups used significantly lower interaction forces than the control group during the knot-tying phase of the postmeasurement task and improved their interaction forces significantly during the knot-tying phase. The form of feedback did not influence its effectiveness. ConclusionThe tissue-handling skills of medical students improved significantly when they were given force feedback of their performance. This effect was seen mainly during the knot-tying phase of the suturing task. Teaching novices how to handle tissue carefully
引用
收藏
页码:1766 / 1773
页数:8
相关论文
共 50 条
  • [1] Force feedback control of robotic forceps for minimally invasive surgery
    Ishii, Chiharu
    Kamei, Yusuke
    [J]. INTELLIGENT SYSTEMS AND AUTOMATION, 2008, 1019 : 154 - +
  • [2] The influence of force feedback and visual feedback in grasping tissue laparoscopically
    Heijnsdijk, EAM
    Pasdeloup, A
    van der Pijl, AJ
    Dankelman, J
    Gouma, DJ
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2004, 18 (06): : 980 - 985
  • [3] The influence of force feedback and visual feedback in grasping tissue laparoscopicaUy
    E. A. M. Heijnsdijk
    A. Pasdeloup
    A. J. van der Pijl
    J. Dankelman
    D. J. Gouma
    [J]. Surgical Endoscopy, 2004, 18 : 980 - 985
  • [4] A hydraulic forceps with force-feedback for use in minimally invasive surgery
    Lazeroms, M
    LaHaye, A
    Sjoerdsma, W
    Schreurs, W
    Jongkind, W
    Honderd, G
    Grimbergen, C
    [J]. MECHATRONICS, 1996, 6 (04) : 437 - 446
  • [5] An ASIC for Gripper Finger Haptic Force Feedback in Minimally Invasive Surgery
    Jin, Han
    Li, Jianzheng
    Huang, Xiongchuan
    Qin, Yajie
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2023, 17 (02) : 336 - 348
  • [6] Force feedback for virtual reality based minimally invasive surgery simulator
    Baumann, R
    Glauser, D
    Tappy, D
    Baur, C
    Clavel, R
    [J]. MEDICINE MEETS VIRTUAL REALITY: HEALTH CARE IN THE INFORMATION AGE, 1996, 29 : 564 - 579
  • [7] A micro optical force sensor for force feedback during minimally invasive robotic surgery
    Peirs, J
    Clijnen, J
    Reynaerts, D
    Van Brussel, H
    Herijgers, P
    Corteville, B
    Boone, S
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2004, 115 (2-3) : 447 - 455
  • [8] 3D surgery trainer with force feedback in minimally invasive surgery.
    Meier, U
    García, FJ
    Parr, NC
    Monserrat, C
    Gil, JA
    Grau, V
    Juan, MC
    Alcañiz, M
    [J]. CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 33 - 38
  • [9] Force feedback plays a significant role in minimally invasive surgery - Results and analysis
    Tholey, G
    Desai, JP
    Castellanos, AE
    [J]. ANNALS OF SURGERY, 2005, 241 (01) : 102 - 109
  • [10] Effects of realistic force feedback in a robotic assisted minimally invasive surgery system
    Dalvand, Mohsen Moradi
    Shirinzadeh, Bijan
    Nahavandi, Saeid
    Smith, Julian
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2014, 23 (3-4) : 127 - 135