Reliability and reproducibility of automated contour analysis in intravascular ultrasound images of femoropopliteal arteries

被引:8
|
作者
van der Lugt, A
Hartlooper, A
van Essen, JA
Li, WG
von Birgelen, C
Reiber, JHC
Gussenhoven, EJ
机构
[1] Univ Hosp Dijkzigt, Dept Radiol, NL-3015 GD Rotterdam, Netherlands
[2] Univ Hosp Dijkzigt, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
[3] Leiden Univ Hosp, Lab Clin Expt Imaging, Leiden, Netherlands
[4] Interuniv Cardiol Inst Netherlands, Rotterdam, Netherlands
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1998年 / 24卷 / 01期
关键词
intravascular ultrasound; contour detection; peripheral arteries; atherosclerosis;
D O I
10.1016/S0301-5629(97)00238-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
An automated contour analysis system was previously developed to increase reproducibility and facilitate quantitative analyses of intravascular ultrasound (IVUS) images, The aim of this study was to compare measurements by this automated system with those obtained by conventional manual tracing, and to determine the intra-and interobserver variability of the automated system, IVUS images obtained in the femoropopliteal artery (n = 12) were analyzed with both systems, Area measurements by the automated system agreed well with the results obtained by manual tracing, displaying low coefficients of variation (8.5 to 15.7%) and high correlation coefficients (r = 0.92 to 0.98), Intra-and interobserver comparison of lumen area, vessel area, plaque area and percentage area stenosis showed low coefficients of variation (6.0 to 15.3% and 5.7 to 14.0%, respectively) and high correlation coefficients (both: r = 0.93 to 0.99), These data indicate that the automated analysis system is a reliable tool for the quantitative assessment of vessel dimensions in IVUS images obtained during clinical examination of peripheral arteries. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:43 / 50
页数:8
相关论文
共 50 条
  • [1] Automated contour analysis of lumen and vessel area in intravascular ultrasound images obtained in peripheral arteries: A validation study
    VanderLugt, A
    Gussenhoven, EJ
    VanEssen, JA
    Hartlooper, A
    VonBirgelen, C
    Li, W
    [J]. RADIOLOGY, 1997, 205 : 1712 - 1712
  • [2] Validation of automated contour analysis of intravascular ultrasound images after vascular intervention
    Hartlooper, A
    van Essen, JA
    van der Lugt, A
    van Sambeek, MRHM
    van Overhagen, H
    Gussenhoven, EJ
    [J]. JOURNAL OF VASCULAR SURGERY, 1998, 27 (03) : 486 - 491
  • [3] A novel active contour model for fully automated segmentation of intravascular ultrasound images: In vivo validation in human coronary arteries
    Giannoglou, George D.
    Chatzizisis, Yiannis S.
    Koutkias, Vassilis
    Kompatsiaris, Loannis
    Papadogiorgaki, Maria
    Mezaris, Vasileios
    Parissi, Eirini
    Diamantopoulos, Panagiotis
    Strintzis, Michael G.
    Maglaveras, Nicos
    Parcharidis, George E.
    Louridas, George E.
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2007, 37 (09) : 1292 - 1302
  • [4] Effect of balloon angioplasty in femoropopliteal arteries assessed by intravascular ultrasound
    vanderLugt, A
    Gussenhoven, EJ
    Mali, WPTM
    Reekers, JA
    Seelen, JL
    Tielbeek, AV
    Pieterman, H
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 13 (06) : 549 - 556
  • [5] An automated approach for segmentation of intravascular ultrasound images based on parametric active contour models
    Alireza Vard
    Kamal Jamshidi
    Naser Movahhedinia
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 135 - 150
  • [6] An automated approach for segmentation of intravascular ultrasound images based on parametric active contour models
    Vard, Alireza
    Jamshidi, Kamal
    Movahhedinia, Naser
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (02) : 135 - 150
  • [7] Reproducibility of volumetric quantification in intravascular ultrasound images
    Hagenaars, T
    Gussenhoven, EJ
    van Essen, JA
    Seelen, J
    Honkoop, J
    van der Lugt, A
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03): : 367 - 374
  • [8] Analysis of reproducibility of reference lumen quantitation with intravascular ultrasound in stented coronary arteries
    Kearney, PP
    Ramo, MP
    Shaw, TRD
    Starkey, IR
    McMurray, JV
    Sutherland, GR
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1997, 40 (01): : 1 - 7
  • [9] Automated morphometry of coronary arteries with digital image analysis of intravascular ultrasound
    Meier, DS
    Cothern, RM
    Vince, DG
    Cornhill, JF
    [J]. AMERICAN HEART JOURNAL, 1997, 133 (06) : 681 - 690
  • [10] Reproducibility of Femoropopliteal Artery Intravascular Ultrasound Imaging in Patients With Peripheral Artery Disease
    Soney, Hywel
    Kakkilaya, Akash
    Vazquez, David Fernandez
    Banerjee, Rahul
    Rosol, Zachary
    Tsai, Shirling
    Banerjee, Subhash
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2023, 199 : 1 - 6