Assessment of LV ejection fraction using real-time 3D echocardiography in daily practice: direct comparison of the volumetric and speckle tracking methodologies to CMR

被引:24
|
作者
Driessen, M. M. P. [1 ,2 ]
Kort, E. [1 ]
Cramer, M. J. M. [1 ]
Doevendans, P. A. [1 ]
Angevaare, M. J.
Leiner, T. [3 ]
Meijboom, F. J. [1 ]
Chamuleau, S. A. J. [1 ]
Sieswerda, G. Tj [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Cardiol, NL-3584 CX Utrecht, Netherlands
[2] Netherlands Heart Inst, ICIN, NL-3511 GC Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
关键词
Real-time 3D echocardiography; Daily practice; Observer experience; CMR; LEFT-VENTRICULAR VOLUMES; CARDIOVASCULAR MAGNETIC-RESONANCE; 3-DIMENSIONAL ECHOCARDIOGRAPHY; HEART-FAILURE; QUANTIFICATION; REPRODUCIBILITY; ACCURACY; MRI;
D O I
10.1007/s12471-014-0577-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims This study is the first to directly compare two widely used real-time 3D echocardiography (RT3DE) methods of cardiac magnetic resonance imaging (CMR) and assess their reproducibility in experienced and less experienced observers. Methods Consecutive patients planned for CMR underwent RT3DE within 8 h of CMR with Philips (volumetric method) and Toshiba Artida (speckle tracking method). Left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume (LVEDV) and end-systolic volume (LVESV) were measured using RT3DE, by four trained observers, and compared with CMR values. Results Thirty-five patients were included (49.7+/-15.7 years; 55 % male), 30 (85.7 %) volumetric and 27 (77.1 %) speckle tracking datasets could be analysed. CMR derived LVEDV, LVESV and LVEF were 198+/-58 ml, 106+/-53 ml and 49+/-15 %, respectively. LVEF derived from speckle tracking was accurate and reproducible in all observers (all intra-class correlation coefficients (ICC)>0.86). LVEF derived from the volumetric method correlated well to CMR in experienced observers (ICC 0.85 and 0.86) but only moderately in less experienced observers (ICC 0.58 and 0.77) and was less reproducible in these observers (ICC=0.55). Volumes were significantly underestimated compared with CMR (p<0.001). Conclusion This study demonstrates that both RT3DE methodologies are sufficiently accurate and reproducible for use in daily practice. However, experience importantly influences the accuracy and reproducibility of the volumetric method, which should be considered when introducing this technique into clinical practice.
引用
收藏
页码:383 / 390
页数:8
相关论文
共 50 条
  • [1] Assessment of LV ejection fraction using real-time 3D echocardiography in daily practice: direct comparison of the volumetric and speckle tracking methodologies to CMR
    M. M. P. Driessen
    E. Kort
    M. J. M. Cramer
    P. A. Doevendans
    M. J. Angevaare
    T. Leiner
    F. J. Meijboom
    S. A. J. Chamuleau
    G. Tj Sieswerda
    Netherlands Heart Journal, 2014, 22 : 383 - 390
  • [2] Rapid and accurate measurement of LV mass by biplane real-time 3D echocardiography in patients with concentric LV hypertrophy: comparison to CMR
    Yap, Sing-Chien
    van Geuns, Robert-Jan M.
    Nemes, Attila
    Meijboom, Folkert J.
    McGhie, Jackie S.
    Geleijnse, Marcel L.
    Simoons, Maarten L.
    Roos-Hesselink, Jolien W.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2008, 9 (02): : 255 - 260
  • [3] COMPARISON OF EJECTION FRACTION USING MUGA AND 3D ECHOCARDIOGRAPHY
    DeJong, P. M.
    Pal, R.
    Johri, A.
    Dutchak, P. A.
    Brouillard, D.
    Matangi, M.
    CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S275 - S275
  • [4] Assessment of ventricular volumes and ejection fraction by real-time 3D-Echocardiography in comparison with gated SPECT thallium
    Müller, S
    Bartel, T
    Neubauer, E
    Katz, M
    Marien, D
    Erbel, R
    Pachinger, O
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 468A - 469A
  • [5] Comparison Study of Left Ventricle Ejection Fraction with Real-Time Volumetric 3D and Biplane Modified Simpson Way
    Zhi, Guang
    CIRCULATION, 2010, 122 (02) : E295 - E295
  • [6] Real-time left ventricular speckle tracking in 3D echocardiography with parallel block matching
    Wu, H. S.
    Wang, D.
    Shi, L.
    Yu, C. M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S13 - S13
  • [7] Prognostic Value of LV Deformation Parameters Using 2D and 3D Speckle-Tracking Echocardiography in Asymptomatic Patients With Severe Aortic Stenosis and Preserved LV Ejection Fraction
    Nagata, Yasufumi
    Takeuchi, Masaaki
    Wu, Victor Chien-Chia
    Izumo, Masaki
    Suzuki, Kengo
    Sato, Kimi
    Seo, Yoshihiro
    Akashi, Yoshihiro J.
    Aonuma, Kazutaka
    Otsuji, Yutaka
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (03) : 235 - 245
  • [8] Automatic 3D echocardiography for left ventricular ejection fraction assessment in daily clinical practice: the present and the future
    Francisco Javier Irazusta Cordoba, F. J.
    Lopez Fernandez, T.
    Rial Baston, V.
    Meras Colunga, P.
    Gonzalez Fernandez, O.
    Blazquez Bermejo, Z.
    Caron Codon, J.
    Refoyo Salicio, E.
    Dalmau Gonzalez-Gallarza, R.
    Guzman Martinez, G.
    Dominguez Melcon, F.
    Rosillo Rodriguez, S. O.
    Moreno Yanguela, M.
    Lopez-Sendon, J. L.
    EUROPEAN JOURNAL OF HEART FAILURE, 2017, 19 : 472 - 473
  • [9] Parameterization of Real-Time 3D Speckle Tracking Framework for Cardiac Strain Assessment
    Lorsakul, Auranuch
    Duan, Qi
    Po, Ming Jack
    Angelini, Elsa
    Homma, Shunichi
    Laine, Andrew F.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2654 - 2657
  • [10] Left ventricular ejection fraction by real-time 3D echocardiography: Comparison to 2D echo and radionuclide angiography.
    Mondelli, JA
    Nagaraj, A
    De Rango, A
    McPherson, DD
    Rigolin, VH
    JOURNAL OF INVESTIGATIVE MEDICINE, 2000, 48 (05) : 240A - 240A