Dual-energy cone-beam Micro-CT for animal imaging: Preliminary study

被引:0
|
作者
Cho, Seungryong [1 ,2 ]
Sidky, Emil [1 ]
Bian, Junguo [1 ]
Pan, Xiaochuan [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
关键词
D O I
10.1117/12.713243
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have recently developed a prototype cone-beam micro-CT system for studying new image reconstruction algorithms experimentally as well as for small animal imaging. Dual energy methods have widely been investigated and applied for eliminating beam hardening artifacts in the reconstructed images and for performing quantitative CT We have proposed earlier a pre-reconstruction-type dual energy method which has the advantage that the cone-beam CT data from two measurements with different x-ray energy spectra are first processed to obtain quantities that are approximately consistent with the x-ray transform, and then image reconstruction is performed. In this work, the proposed method is applied to the cone-beam micro-CT data acquired by our prototype system. Only the thickness maps of the object based on projection images are shown in this work as a preliminary.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Dual Energy CT Imaging in Cone-Beam Micro-CT for Improved Attenuation Coefficient Measurement
    唐智伟
    胡广书
    [J]. Tsinghua Science and Technology, 2011, 16 (04) : 352 - 357
  • [2] HELICAL DUAL SOURCE CONE-BEAM MICRO-CT
    Johnston, Samuel M.
    Johnson, G. Allan
    Badea, Cristian T.
    [J]. 2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 177 - 180
  • [3] Circular Cone-beam Micro-CT for Small Animal Imaging with Truncated Data
    Cho, Seungryong
    Yu, Lifeng
    Pelizzari, Charles A.
    Pan, Xiaochuan
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2889 - 2891
  • [4] Cone-beam reconstruction for micro-CT
    Wang, G
    Jiang, M
    Lee, SW
    Liu, H
    Hoffman, E
    [J]. 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 384 - 387
  • [5] Dual-energy approach to reduce cone-beam artefacts in a circular orbit cone-beam CT system
    Han, C.
    Baek, J.
    [J]. ELECTRONICS LETTERS, 2020, 56 (13) : 648 - 650
  • [6] Magnitude and effects of X-ray scatter of a cone-beam micro-CT for small animal imaging
    Ni, Y. C.
    Jan, M. L.
    Chen, K. W.
    Cheng, Y. D.
    Chuang, K. S.
    Fu, Y. K.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 245 - 249
  • [7] Framework for iterative cone-beam micro-CT reconstruction
    Benson, TM
    Gregor, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1335 - 1340
  • [8] Framework for iterative cone-beam micro-CT reconstruction
    Benson, T
    Gregor, J
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3253 - 3257
  • [9] Feasibility study of three-material decomposition in dual-energy cone-beam CT imaging with deep learning
    Zhu, Jiongtao
    Su, Ting
    Zhang, Xin
    Yang, Jiecheng
    Mi, Donghua
    Zhang, Yunxin
    Gao, Xiang
    Zheng, Hairong
    Liang, Dong
    Ge, Yongshuai
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (14):
  • [10] Cardiac Perfusion Imaging of Small Rodents using Cone-Beam Micro-CT
    Sawall, Stefan
    Kuntz, Jan
    Socher, Michaela
    Bartling, Soenke
    Knaup, Michael
    Kachelriess, Marc
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2425 - 2428