The efficacy of Raman spectroscopy in lung cancer diagnosis: the first diagnostic meta-analysis

被引:9
|
作者
Ke, Zhang-Yan [1 ]
Ning, Ya-Jing [1 ]
Jiang, Zi-Feng [1 ]
Zhu, Ying-ying [1 ]
Guo, Jia [2 ]
Fan, Xiao-Yun [1 ]
Zhang, Yan-Bei [1 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Geriatr Resp & Crit Care, Inst Resp Dis, Hefei 230032, Anhui, Peoples R China
[2] Univ Tasmania, Menzies Inst Med Res, Hobart, Tas, Australia
关键词
Lung cancer; Raman spectroscopy; Diagnostic performance; Meta-analysis; DISCRIMINATION; OVARIAN; BREAST; ROC;
D O I
10.1007/s10103-021-03275-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In recent years, many researches have explored the diagnostic value of Raman spectroscopy in multiple types of tumors. However, as an emerging clinical examination method, the diagnostic performance of Raman spectroscopy in lung cancer remains unclear. Relevant diagnostic studies published before 1 June 2020 were retrieved from the Cochrane Library, PubMed, EMBASE, China National Knowledge Internet (CNKI), and WanFang databases. After the literature was screened, two authors extracted the data from eligible studies according to the inclusion and exclusion criteria. Obtained data were pooled and analyzed using Stata 16.0, Meta-DiSc 1.4, and RevMan 5.3 software. Fourteen diagnostic studies were eligible for the pooled analysis which includes 779 patients. Total pooled sensitivity and specificity of Raman spectroscopy in diagnosing lung cancer were 0.92 (95% CI 0.87-0.95) and 0.94 (95% CI 0.88-0.97), respectively. The positive likelihood ratio was 15.2 (95% CI 7.5-30.9), the negative likelihood ratio was 0.09 (95% CI 0.05-0.14), and the area under the curve was 0.97 (95 % CI 0.95-0.98). Subgroup analysis suggested that the sensitivity and specificity of RS when analyzing human tissue, serum, and saliva samples were 0.95 (95% CI 0.88-0.98), 0.97 (95% CI 0.89-0.99), 0.88 (95% CI 0.80-0.93), 0.87 (95% CI 0.78-0.92), 0.91 (95% CI 0.80-0.96), and 0.95 (95% CI 0.73-0.99), respectively. No publication bias or threshold effects were detected in this meta-analysis. This initial meta-analysis indicated that Raman spectroscopy is a highly specific and sensitive diagnostic technology for detecting lung cancer. Further investigations are also needed to focus on real-time detection using Raman spectroscopy under bronchoscopy in vivo. Moreover, large-scale diagnostic studies should be conducted to confirm this conclusion.
引用
收藏
页码:425 / 434
页数:10
相关论文
共 50 条
  • [1] The efficacy of Raman spectroscopy in lung cancer diagnosis: the first diagnostic meta-analysis
    Zhang-Yan Ke
    Ya-Jing Ning
    Zi-Feng Jiang
    Ying-ying Zhu
    Jia Guo
    Xiao-Yun Fan
    Yan-Bei Zhang
    [J]. Lasers in Medical Science, 2022, 37 : 425 - 434
  • [2] The efficacy of Raman spectroscopy in the diagnosis of esophageal cancer: a systematic review and meta-analysis
    Hao, Jianqi
    Chen, Cong
    Jin, Hongyu
    Chen, Nan
    Zhou, Jian
    Zhu, Yuzhou
    Chung, Kayi
    Pu, Qiang
    [J]. TRANSLATIONAL CANCER RESEARCH, 2020, 9 (08) : 4750 - 4761
  • [3] Efficacy of raman spectroscopy in the diagnosis of kidney cancer A systematic review and meta-analysis
    Jin, Hongyu
    He, Xiao
    Zhou, Hui
    Zhang, Man
    Tang, Qingqing
    Lin, Lede
    Hao, Jianqi
    Zeng, Rui
    [J]. MEDICINE, 2020, 99 (27)
  • [4] Efficacy of Raman spectroscopy in the diagnosis of bladder cancer A systematic review and meta-analysis
    Jin, Hongyu
    Lin, Tianhai
    Han, Ping
    Yao, Yijun
    Zheng, Danxi
    Hao, Jianqi
    Hu, Yiqing
    Zeng, Rui
    [J]. MEDICINE, 2019, 98 (47)
  • [5] The accuracy of Raman spectroscopy in the diagnosis of lung cancer: a systematic review and meta-analysis
    Chen, Cong
    Hao, Jianqi
    Hao, Xiaohu
    Xu, Wenying
    Xiao, Congjia
    Zhang, Jian
    Pu, Qiang
    Liu, Lunxu
    [J]. TRANSLATIONAL CANCER RESEARCH, 2021, 10 (08) : 3680 - 3693
  • [6] Diagnostic accuracy of Raman spectroscopy for the diagnosis of bladder cancer: A systematic review and meta-analysis
    Kim, Do Kyung
    Kim, Yon Hee
    Lee, Hyun Young
    Lee, Soomin
    Doo, Seung Whan
    Yang, Won Jae
    Song, Yun Seob
    Kim, Ki Hyun
    Kim, Jae Heon
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (02) : 426 - 433
  • [7] Diagnosis accuracy of Raman spectroscopy in the diagnosis of breast cancer: a meta-analysis
    Mei-Huan Wang
    Xiao Liu
    Qian Wang
    Hua-Wei Zhang
    [J]. Analytical and Bioanalytical Chemistry, 2022, 414 : 7911 - 7922
  • [8] Diagnosis accuracy of Raman spectroscopy in the diagnosis of breast cancer: a meta-analysis
    Wang, Mei-Huan
    Liu, Xiao
    Wang, Qian
    Zhang, Hua-Wei
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (27) : 7911 - 7922
  • [9] Efficacy of Raman Spectroscopy in the Diagnosis of Uterine Cervical Neoplasms: A Meta-Analysis
    Shen, Zhuo-Wei
    Zhang, Li-Jie
    Shen, Zhuo-Yi
    Zhang, Zhi-Feng
    Xu, Fan
    Zhang, Xiao
    Li, Rui
    Xiao, Zhen
    [J]. FRONTIERS IN MEDICINE, 2022, 9
  • [10] Diagnostic accuracy of Raman spectroscopy for prostate cancer: a systematic review and meta-analysis
    Park, Jae Joon
    Kim, Do Kyung
    Lee, Soomin
    Choi, Yoonseo
    Kim, Yon Hee
    Lee, Joon-Ho
    Kim, Ki Hyun
    Kim, Jae Heon
    [J]. TRANSLATIONAL ANDROLOGY AND UROLOGY, 2021, 10 (02) : 574 - 583