Liquid chromatographic high-resolution mass spectrometric and tandem mass spectrometric identification of synthetic peptides, using electrospray ionization

被引:17
|
作者
D'Agostino, PA
Hancock, JR
Provost, LR
Semchuk, PD
Hodges, RS
机构
[1] Def Res Estab Suffield, Medicine Hat, AB T1A 8K6, Canada
[2] Univ Alberta, Dept Biochem, Edmonton, AB T6G 2H7, Canada
[3] Univ Alberta, Protein Engn Network Ctr Excellence, Edmonton, AB T6G 2H7, Canada
关键词
liquid chromatography -mass spectrometry; electrospray ionization; peptides;
D O I
10.1016/S0021-9673(97)01104-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography-high-resolution electrospray mass spectrometry (LC-EST-MS) was investigated for the identification of known and unknown synthetic peptides in a research effort designed to evaluate the applicability of this and complementary MS techniques for peptide characterization and identification. The monoisotopic molecular masses of five related peptides with molecular masses between 2000 and 2500 u were acquired with a resolution of 3000 (10% valley). Under narrow and wide mass range magnetic sector scanning conditions monoisotopic molecular mass errors were typically in the 10-20 and 30-40 ppm range, respectively. Tryptic maps were generated for each peptide following LC-ESI-MS analysis and collisionally activated dissociation (CAD) in the ESI interface resulted in the production of characteristic product ions that enabled amino acid sequencing of the tryptic fragments. Unknown identification was demonstrated during analysis of an incomplete synthetic peptide reaction mixture. The synthesis of an 18 amino acid peptide, LTTAVKKVLTTGLPALIS, was not successful. In its place were six unknown peptides that were identified on the basis of monoisotopic molecular mass and amino acid sequence data. The monoisotopic molecular masses of these unknowns were determined to within 10-20 ppm with a resolution of 3500 (10% valley). Amino acid sequences for the six peptides were generated during ESI-MS-MS analysis. Finally two synthetic peptides differing only by the incorporation of a C-13 at leucine were analysed with a resolution of 6000 (10% valley) to confirm that the isotopic distributions were consistent with theoretical expectations. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:89 / 100
页数:12
相关论文
共 50 条
  • [1] Electrospray ionization mass spectrometric and liquid chromatographic mass spectrometric studies on the metabolism of synthetic dynorphin A peptides in brain tissue in vitro and in vivo
    Prokai, L
    Kim, HS
    Zharikova, A
    Roboz, J
    Ma, L
    Deng, L
    Simonsick, WJ
    JOURNAL OF CHROMATOGRAPHY A, 1998, 800 (01) : 59 - 68
  • [2] Determination of acidic herbicides using liquid chromatography with pneumatically assisted electrospray ionization mass spectrometric and tandem mass spectrometric detection
    Koppen, B
    Spliid, NH
    JOURNAL OF CHROMATOGRAPHY A, 1998, 803 (1-2) : 157 - 168
  • [3] Identification of protein ubiquitylation by electrospray ionization tandem mass spectrometric analysis of sulfonated tryptic peptides
    Wang, Dongxia
    Kalume, Dario
    Pickart, Cecile
    Pandey, Akhilesh
    Cotter, Robert J.
    ANALYTICAL CHEMISTRY, 2006, 78 (11) : 3681 - 3687
  • [4] Liquid chromatographic/electrospray ionization mass spectrometric studies of proanthocyanidins in foods
    Gu, LW
    Kelm, MA
    Hammerstone, JF
    Zhang, Z
    Beecher, G
    Holden, J
    Haytowitz, D
    Prior, RL
    JOURNAL OF MASS SPECTROMETRY, 2003, 38 (12): : 1272 - 1280
  • [5] Liquid Chromatographic Analysis and Mass Spectrometric Identification of Farnesylated Peptides
    Wotske, Marina
    Wu, Yaowen
    Wolters, Dirk A.
    ANALYTICAL CHEMISTRY, 2012, 84 (15) : 6848 - 6855
  • [6] Liquid chromatographic/electrospray ionization tandem mass spectrometric study of the phenolic composition of cocoa (Theobroma cacao)
    Sánchez-Rabaneda, F
    Jáuregui, O
    Casals, I
    Andrés-Lacueva, C
    Izquierdo-Pulido, M
    Lamuela-Raventós, RM
    JOURNAL OF MASS SPECTROMETRY, 2003, 38 (01): : 35 - 42
  • [7] Mass spectrometric and tandem mass spectrometric behavior of nitrocatechol glucuronides:: A comparison of atmospheric pressure chemical ionization and electrospray ionization
    Keski-Hynnilä, H
    Luukkanen, L
    Taskinen, J
    Kostiainen, R
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (06) : 537 - 545
  • [8] Liquid chromatographic-electrospray tandem mass spectrometric determination of bisoprolol in human plasma
    Liu, Mingyuan
    Zhang, Dan
    Sun, Yantong
    Wang, Yingwu
    Liu, Zeyuan
    Gu, Jingkai
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (05) : 508 - 513
  • [9] Liquid chromatographic-electrospray tandem mass spectrometric determination of clarithromycin in human plasma
    Li, Wenkui
    Rettig, Joan
    Jiang, Xiangyu
    Francisco, Diane T.
    Weng Naidong
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (11) : 1242 - 1251
  • [10] Liquid chromatographic electrospray tandem mass spectrometric determination of novel antifungal agents in plasma
    Bu, HZ
    Khan, JK
    Poglod, M
    Micetich, RG
    JOURNAL OF CHROMATOGRAPHY B, 1999, 724 (02): : 311 - 317