Wavefront Analysis, Contrast Sensitivity, and Depth of Focus After Cataract Surgery With Aspherical Intraocular Lens Implantation

被引:30
|
作者
Santhiago, Marcony R. [1 ]
Netto, Marcelo V. [1 ]
Barreto, Jackson, Jr. [1 ]
Gomes, Beatriz A. F. [2 ]
Mukai, Adriana [1 ]
Calil Guermandi, Ana Paula [1 ]
Kara-Junior, Newton [1 ]
机构
[1] Univ Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[2] Univ Fed Rio de Janeiro, Dept Ophthalmol, Rio De Janeiro, Brazil
关键词
ANTERIOR CAPSULE CONTRACTION; HIGHER-ORDER ABERRATIONS; SPHERICAL-ABERRATION; VISUAL PERFORMANCE; OPTICAL-QUALITY; EYES; TECNIS; DISLOCATION; DESIGN; ACUITY;
D O I
10.1016/j.ajo.2009.09.019
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery without critical reduction of depth of focus. DESIGN: Double-blinded, randomized, prospective study. METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distance-corrected near and intermediate visual acuity were studied as a measurement of depth of focus. RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at I and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups. CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity was better under mesopic conditions with the Akreos AO with similar results of depth of focus. (Am J Ophthalmol 2010;149:383-389. (C) 2010 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:383 / 389
页数:7
相关论文
共 50 条
  • [1] Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery
    Kurz, Sabine
    Krummenauer, Frank
    Thieme, Hagen
    Dick, H. Burkhard
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03): : 393 - 400
  • [2] Contrast sensitivity function after cataract extraction and intraocular lens implantation
    Mela, EK
    Gartaganis, SP
    Koliopoulos, JX
    [J]. DOCUMENTA OPHTHALMOLOGICA, 1996, 92 (02) : 79 - 91
  • [3] Comparison of wavefront aberration after cataract surgery with acrylic intraocular lens implantation
    Choi, J
    Kim, TI
    Tchah, H
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (02): : 324 - 329
  • [4] Effect of intraocular lens implantation on visual acuity, contrast sensitivity, and depth of focus
    Nio, YK
    Jansonius, NM
    Geraghty, E
    Norrby, S
    Kooijman, AC
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11): : 2073 - 2081
  • [5] Ocular aberrations and contrast sensitivity after cataract surgery with AcrySof IQ intraocular lens implantation: Clinical comparative study
    Tzelikis, Patrick F.
    Akaishi, Leonardo
    Trindade, Fernando C.
    Boteon, Joel E.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11): : 1918 - 1924
  • [6] Quality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation - Effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision
    Denoyer, Alexandre
    Le Lez, Marie-Laure
    Majzoub, Samuel
    Pisella, Pierre-Jean
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (02): : 210 - 216
  • [7] Effects on ocular aberration and contrast sensitivity after implantation of spherical and aspherical monofocal intraocular lens - A comparative study
    Deshpande, Rahul
    Satijia, Anuj
    Dole, Kuldeep
    Mangiraj, Varsha
    Deshpande, Madan
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (08) : 2862 - 2865
  • [9] Aberrometry and contrast sensitivity after cataract surgery: aspherical IOL evaluation
    Montard, R.
    Putz, C.
    Creisson, G.
    Montard, M.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2008, 31 (03): : 257 - 262
  • [10] Secondary intraocular lens implantation after cataract surgery in children
    Biglan, AW
    Cheng, KP
    Davis, JS
    Gerontis, CC
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 123 (02) : 224 - 234