Comparison of success criteria based on long-term symptoms and new-onset hypertension in mandibular advancement device treatment for obstructive sleep apnoea: observational cohort study

被引:7
|
作者
Wee, Jee Hye [1 ]
Lim, Jae Hyun [2 ]
Gelera, January E. [2 ,3 ]
Rhee, Chae-Seo [2 ]
Kim, Jeong-Whun [2 ]
机构
[1] Bundang Jesaeng Gen Hosp, Daejin Med Ctr, Dept Otorhinolaryngol Head & Neck Surg, Seongnam, South Korea
[2] Seoul Natl Univ, Bundang Hosp, Coll Med, Dept Otorhinolaryngol Head & Neck Surg, Seoul, South Korea
[3] Univ Santo Tomas Hosp, Dept Otorhinolaryngol Head & Neck Surg, Manila, Philippines
来源
BMJ OPEN | 2018年 / 8卷 / 05期
基金
新加坡国家研究基金会;
关键词
POSITIVE AIRWAY PRESSURE; ORAL APPLIANCE TREATMENT; BLOOD-PRESSURE; CARDIOVASCULAR-DISEASE; RISK-FACTOR; CPAP; ASSOCIATION; GUIDELINE; SELECTION; EFFICACY;
D O I
10.1136/bmjopen-2018-021644
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To identify adequate criteria to determine the success or failure of mandibular advancement device (MAD) treatment for obstructive sleep apnoea (OSA) based on long-term symptoms and new-onset hypertension. Design Observational cohort study. Setting A tertiary care hospital setting in South Korea. Participants Patients (age >18 years) who were diagnosed with OSA by a polysomnography (PSG) or Watch peripheral arterial tonometry (PAT), and who had been treated with MAD between January 2007 and December 2014 were enrolled. Primary and secondary outcome measures Patients underwent PSG or Watch PAT twice; before and 3 months after the application of MAD. The patients were categorised into success and failure groups using seven different criteria. MAD compliance, witnessed apnoea and snoring, Epworth Sleepiness Scale score and occurrence of new-onset hypertension were surveyed via telephonic interview to determine the criteria that could identify success and failure of MAD. Results A total of 97 patients were included. The mean follow-up duration was 60.5 months, and the mean apnoea-hypopnoea index (AHI) was 35.5/hour. Two of the seven criteria could significantly differentiate the success and failure groups based on long-term symptoms, including (1) AHI<10/hour with MAD and (2) AHI<10/ hour and AHI reduction of >50% with MAD. Kaplan-Meier survival analysis showed that one criterion of AHl<15/ hour with MAD could differentiate the success and failure groups based on new-onset hypertension (p=0.035). The receiver operating characteristic curve analysis indicated that the cut-off AHI for new-onset hypertension was 16.8/ hour (71.4% sensitivity and 75.0% specificity). Conclusion Our long-term follow-up survey for symptoms and new-onset hypertension suggested that some of the polysomnographic success criteria, that is, AHI<10/ hour with MAD, AHI<10/hour and AHI reduction of >50% with MAD and AHI<15/hour with MAD may be useful in distinguishing the success group from failure one. Further prospective longitudinal studies are warranted to validate these criteria.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A mandibular advancement device for the treatment of obstructive sleep apnea: Long-term use and tolerance
    Brette, Christophe
    Ramanantsoa, Hassina
    Renouardiere, Joel
    Renouardiere, Rosine
    Roisman, Gabriel
    Escourrou, Pierre
    INTERNATIONAL ORTHODONTICS, 2012, 10 (04) : 363 - 376
  • [2] Daytime Sleepiness and Quality of Life in Obstructive Sleep Apnoea Patients before and after Long-Term Mandibular Advancement Device Treatment
    Halfeld, Signe
    Sonnesen, Liselotte
    DENTISTRY JOURNAL, 2022, 10 (12)
  • [3] Long-term use of mandibular advancement splints for snoring and obstructive sleep apnoea: a questionnaire survey
    McGown, AD
    Makker, HK
    Battagel, JM
    L'Estrange, PR
    Grant, HR
    Spiro, SG
    EUROPEAN RESPIRATORY JOURNAL, 2001, 17 (03) : 462 - 466
  • [4] Evaluation of the success of obstructive sleep apnea surgery using criteria based on long-term symptoms and incident hypertension
    Jae Hyun Lim
    Pona Park
    Jee Hye Wee
    January E. Gelera
    Kundan Kumar Shrestha
    Chae-Seo Rhee
    Jeong-Whun Kim
    European Archives of Oto-Rhino-Laryngology, 2018, 275 : 1015 - 1022
  • [5] Evaluation of the success of obstructive sleep apnea surgery using criteria based on long-term symptoms and incident hypertension
    Lim, Jae Hyun
    Park, Pona
    Wee, Jee Hye
    Gelera, January E.
    Shrestha, Kundan Kumar
    Rhee, Chae-Seo
    Kim, Jeong-Whun
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2018, 275 (04) : 1015 - 1022
  • [6] Mandibular advancement device in patients with obstructive sleep apnea - Long-term effects on apnea and sleep
    Marklund, M
    Sahlin, C
    Stenlund, H
    Persson, M
    Franklin, KA
    CHEST, 2001, 120 (01) : 162 - 169
  • [7] Comparison of titrable thermoplastic versus custom-made mandibular advancement device for the treatment of obstructive sleep apnoea
    Gagnadoux, Frederic
    Xuan-Lan Nguyen
    Le Vaillant, Marc
    Priou, Pascaline
    Meslier, Nicole
    Eberlein, Audrey
    Kun-Darbois, Jean-Daniel
    Chaufton, Cyril
    Villiers, Bruno
    Levy, Maguy
    Trzepizur, Wojciech
    Launois, Sandrine
    RESPIRATORY MEDICINE, 2017, 131 : 35 - 42
  • [8] Mandibular advancement device therapy for obstructive sleep apnea: a prospective study on predictors of treatment success
    Petri, Niels
    Christensen, Ib Jarle
    Svanholt, Palle
    Sonnesen, Liselotte
    Wildschiodtz, Gordon
    Berg, Soren
    SLEEP MEDICINE, 2019, 54 : 187 - 194
  • [9] Long-term dentofacial changes in Chinese obstructive sleep apnea patients after treatment with a mandibular advancement device
    Hou, HM
    Sam, K
    Hägg, U
    Rabie, ABM
    Bendeus, M
    Yam, LYC
    Ip, MS
    ANGLE ORTHODONTIST, 2006, 76 (03) : 432 - 440
  • [10] Long-term dental and skeletal effects of mandibular advancement devices in adults with obstructive sleep apnoea: A systematic review
    Patel, Sita
    Rinchuse, Daniel
    Zullo, Thomas
    Wadhwa, Rekha
    INTERNATIONAL ORTHODONTICS, 2019, 17 (01) : 3 - 11