Determination of glucosamine in nutritional supplements by reversed-phase ion-pairing HPLC

被引:20
|
作者
Way, WK [1 ]
Gibson, KG [1 ]
Breite, AG [1 ]
机构
[1] Chemir Polytech Labs Inc, Maryland Hts, MO 63043 USA
关键词
D O I
10.1081/JLC-100101238
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A reverse-phase high performance liquid chromatography (HPLC) method for the determination of glucosamine in nutritional supplements was developed and validated based on USP guidelines. Separations were performed using a MetaChem Inertsil ODS-3 column with an isocratic mobile phase consisting of 10% Methanol, 90% 0.005M octanesulfonate, pH = 2.1. Glucosamine was detected using a refractive index (RI) detector. The octanesulfonate ion pairing agent allowed for retention on a C-18 column. The method proved highly reliable with respect to standard performance characteristics. The method allows for convenient quality control in the growing nutritional supplement market.
引用
收藏
页码:2861 / 2871
页数:11
相关论文
共 50 条
  • [1] A SENSITIVE REVERSED-PHASE ION-PAIRING HPLC METHOD FOR THE DETERMINATION OF POLYAMINES IN RAT-LIVER
    DANNER, RM
    REDDY, TV
    GUION, CW
    LC GC NORTH AMERICA, 1994, 12 (03) : 244 - +
  • [2] Separation of modified 2′-deoxyoligonucleotides using ion-pairing reversed-phase HPLC
    Gelhaus, SL
    LaCourse, WR
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (02): : 157 - 163
  • [3] Phosphorothioate oligonucleotides separation in ion-pairing reversed-phase liquid chromatography: Effect of ion-pairing system
    Kadlecova, Zuzana
    Kalikova, Kveta
    Tesarova, Eva
    Gilar, Martin
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1676
  • [4] RAPID OPTIMIZATION OF THE CONCENTRATION OF THE ION-PAIRING REAGENT IN ION-PAIRING REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    BILLIET, HAH
    DROUEN, ACJH
    DEGALAN, L
    JOURNAL OF CHROMATOGRAPHY, 1984, 316 (DEC): : 231 - 240
  • [5] Modeling of ion-pairing effect in peptide reversed-phase chromatography
    Getaz, David
    Hariharan, Subrahmaniam B.
    Butte, Alessandro
    Morbidelli, Massimo
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1249 : 92 - 102
  • [6] FLUORESCENCE DETERMINATION OF STREPTOMYCIN IN SERUM BY REVERSED-PHASE ION-PAIRING LIQUID-CHROMATOGRAPHY
    KUBO, H
    KOBAYASHI, Y
    KINOSHITA, T
    ANALYTICAL CHEMISTRY, 1986, 58 (13) : 2653 - 2655
  • [7] Determination of dehydroepiandrosterone in dietary supplements by reversed-phase HPLC
    Tabaza, Yahia Z.
    Mansi, Kamal M.
    Azzam, Hanan A.
    Al-Mamoori, Farah F.
    Al-Samydai, Ali M.
    Aburjai, Talal A.
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2021, 20 (02) : 383 - 387
  • [8] Supramolecular Solvent-Based Liquid Phase Microextraction Combined with Ion-Pairing Reversed-Phase HPLC for the Determination of Quats in Vegetable Samples
    Hem, Sophon
    Gissawong, Netsirin
    Srijaranai, Supalax
    Boonchiangma, Suthasinee
    TOXICS, 2019, 7 (04)
  • [9] DETECTION BY ION-PAIRING PROBES IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    HACKZELL, L
    SCHILL, G
    CHROMATOGRAPHIA, 1982, 15 (07) : 437 - 444
  • [10] The importance of ion-pairing in peptide purification by reversed-phase liquid chromatography
    Asberg, Dennis
    Weinmann, Annika Langborg
    Leek, Tomas
    Lewis, Richard J.
    Klarqvist, Magnus
    Lesko, Marek
    Kaczmarski, Krzysztof
    Samuelsson, Jorgen
    Fornstedt, Torgny
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1496 : 80 - 91