Energy optimization and Cost Management in multi-storied Green Complexes

被引:0
|
作者
Jhunjhunwala, Ashok [1 ]
Kaur, Prabhjot [1 ]
机构
[1] Indian Inst Technol Madras, Elect Engn Dept, Madras, Tamil Nadu, India
关键词
Green buildings; Efficiency; Solar-DC; Optimization; DC-Powerlines;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As India tries to add significant renewables to its coal-dominated energy mix, the problem of intermittent generation associated with renewables, is likely to be a problem. Even though battery prices have been falling rapidly, any serious grid-level storage will push up the price of electricity beyond the affordability limit for a large section of Indian people. The answer is in developing techniques, practices and policies, which enables the consumers to carry out load-management in response to grid-power availability. If grid-power is surplus, the customer uses grid to the maximal extent, but when grid-power is in deficit, it uses it to minimal extent. This paper focuses on commercial multi-storied buildings and discusses how power-systems can be designed for them to respond to the grid-availability without affecting the working and life-style of people in the building to a significant extent. It proposes use of roof-top solar and DC power-line within buildings along with DC-powered appliances to significantly save energy. It incorporates battery-storage and chilled-water storage, which coupled with use of DC motors or variable frequency drives, can help building cut its load to almost 50% or even less during grid-power shortage and draw power more than its load during surplus situation. The paper goes beyond the concept and discusses actual implementation being carried out today. It also discusses policies which will accelerate deployment of such designs benefiting both the customer as well as the grid-supply.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] The multi-storied consciousness
    Konrad, G
    Polzin, C
    SINN UND FORM, 1998, 50 (02): : 225 - 233
  • [2] Embodied energy analysis of multi-storied residential buildings in urban India
    Bardhan, S.
    ENERGY AND SUSTAINABILITY III, 2011, 143 : 411 - 421
  • [3] ENERGY MODELING OF MULTI-STORIED RESIDENTIAL BUILDINGS - A MANUAL CALIBRATION APPROACH
    Shailza
    2018 BUILDING PERFORMANCE ANALYSIS CONFERENCE AND SIMBUILD, 2018, : 550 - 557
  • [4] THE SUCCESS OF JAVA']JAVANESE MULTI-STORIED GARDENS
    FREEMAN, P
    FRICKE, T
    ECOLOGIST, 1984, 14 (04): : 150 - 152
  • [5] SHEAR-WAVES IN NONHOMOGENEOUS MULTI-STORIED BUILDINGS
    MIODUCHOWSKI, A
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1991, 71 (11): : 443 - 448
  • [6] ISSUES OF SLOPING ROOF DESIGN OF MULTI-STORIED BUILDINGS
    Yan, Yajie
    SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 1179 - 1185
  • [7] COOLING LOAD CALCULATIONS IN A MULTI-STORIED EDUCATIONAL BUILDING
    Gogineni, A.
    Apel, J.
    Abdullah, S. B.
    Pokhrel, B.
    5TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, TFEC 2020, 2020, : 535 - 542
  • [8] QUADRATIC FRICTION EFFECT IN MULTI-STORIED NONLINEAR-SYSTEMS
    GLOUKHOVSKY, AB
    IZVESTIYA AKADEMII NAUK SSSR FIZIKA ATMOSFERY I OKEANA, 1977, 13 (09): : 917 - 925
  • [9] Prototype of an Underground Multi-Storied Automated Car Parking System
    Eswaran, P.
    Manikandan, A. V. M.
    Godha, Saurabh
    2013 IEEE INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN COMPUTING, COMMUNICATION AND NANOTECHNOLOGY (ICE-CCN'13), 2013, : 674 - 677
  • [10] Large Eddy Simulation of Smoke Spread in a Multi-storied Building
    Meher, Srisai
    Khedekar, Gulab A.
    Kumar, Vikas
    Paul, Supriyo
    FLUID MECHANICS AND FLUID POWER - CONTEMPORARY RESEARCH, 2017, : 583 - 593