COMPARISON OF THE NEUTRON ENERGY RESPONSE OF TWO DIFFERENT TLD ALBEDO DOSEMETERS

被引:2
|
作者
Freitas, B. M. [1 ]
da Silva, A. X. [1 ]
Pereira, W. W. [2 ]
Mauricio, C. L. P. [2 ]
机构
[1] Univ Fed Rio de Janeiro, Programa Engn Nucl COPPE, Av Horacio Macedo,2030 Cidade Univ, BR-21941914 Rio De Janeiro, RJ, Brazil
[2] Inst Radioprotecao & Dosimetria, Av Salvador Allende S-N, BR-22783127 Rio De Janeiro, RJ, Brazil
关键词
D O I
10.1093/rpd/ncx256
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Albedo dosemeters remain the most used dosemeters in neutron individual monitoring. In Brazil, most of the neutron occupational fields are from radionuclide sources, often without any moderation, where albedo dosemeters have poor energy response. The purpose of this work is to compare the HP(10) energy response of the IRD and ALNOR TLD albedo dosemeter systems, calculated by their modelling with Monte Carlo code MCNPX. Their energy responses are similar, as expected, but the IRD system is about five times more sensitive than the ALNOR one. IRD albedo system can measure the Brazilian monthly recording level of 0.2 mSv, even for bare Cf-252 and Am-241-Be neutron fields. On the other hand, the ALNOR system can measure values higher than 0.2mSv only after huge moderation of theses sources. These results show that IRD TLD albedo is more suitable than the ALNOR one to measure low doses at occupational fields from radionuclide sources.
引用
收藏
页码:240 / 244
页数:5
相关论文
共 50 条
  • [1] Calibration of neutron albedo dosemeters
    Schwartz, RB
    Eisenhauer, CM
    [J]. RADIATION PROTECTION DOSIMETRY, 2002, 102 (01) : 23 - 30
  • [2] Neutron dosimetry with TL albedo dosemeters at high energy accelerators
    Haninger, T.
    Fehrenbacher, G.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 361 - 363
  • [3] A COMPARISON OF THE RESPONSE OF PADC NEUTRON DOSEMETERS IN HIGH-ENERGY NEUTRON FIELDS
    Trompier, F.
    Boschung, M.
    Buffler, A.
    Domingo, C.
    Cale, E.
    Chevallier, M-A.
    Esposito, A.
    Ferrarini, M.
    Geduld, D. R.
    Hager, L.
    Hohmann, E.
    Mayer, S.
    Musso, A.
    Romero-Esposito, M.
    Roettger, S.
    Smit, F. D.
    Naik, A. Sashala
    Tanner, R.
    Wissmann, F.
    Caresana, M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 78 - 81
  • [4] Operational comparison of TLD albedo dosemeters and solid state nuclear tracks detectors in fuel fabrication facilities
    Tsujimura, N.
    Takada, C.
    Yoshida, T.
    Momose, T.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 383 - 386
  • [5] ANGULAR RESPONSE PERFORMANCE STUDY OF A NEW HARSHAW NEUTRON ALBEDO TLD
    LIU, JC
    SIMS, CS
    WEST, L
    WELTY, T
    [J]. RADIATION PROTECTION DOSIMETRY, 1990, 30 (03) : 161 - 168
  • [6] Brazilian two-component TLD albedo neutron individual monitoring system
    Martins, M. M.
    Mauricio, C. L. P.
    da Fonseca, E. S.
    da Silva, A. X.
    [J]. RADIATION MEASUREMENTS, 2010, 45 (10) : 1509 - 1512
  • [7] Ten years of personal neutron dosimetry with albedo dosemeters in the Netherlands
    Draaisma, FS
    Verhagen, HW
    [J]. RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 293 - 296
  • [8] Ten years of personal neutron dosimetry with albedo dosemeters in the Netherlands
    Draaisma, FS
    Verhagen, HW
    [J]. SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A293 - A296
  • [9] FIELD CALIBRATION OF A TLD ALBEDO DOSEMETER IN THE HIGH-ENERGY NEUTRON FIELD OF CERF
    Haninger, T.
    Kleinau, P.
    Haninger, S.
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 174 (03) : 315 - 321
  • [10] Correlating neutron energy spectra with TLD badge response
    Harris, WS
    Melanson, MA
    Tincher, JW
    [J]. RADIATION SAFETY AND ALARA CONSIDERATIONS FOR THE 21ST CENTURY, 2001, : 89 - 95