共 50 条
Effect of Vertical Permeability Heterogeneity in Stratified Formation on Electricity Generation Performance of Enhanced Geothermal System
被引:2
|作者:
Zeng, Yuchao
[1
]
Sun, Fangdi
[2
]
Zhai, Haizhen
[3
]
机构:
[1] Guangdong Acad Sci, Inst Ecoenvironm & Soil Sci, Guangdong Key Lab Integrated Agroenvironm Pollut, Natl Reg Joint Engn Res Ctr Soil Pollut Control &, Guangzhou 510650, Peoples R China
[2] Guangzhou Univ, Sch Geog & Remote Sensing, Guangzhou 510006, Peoples R China
[3] Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Peoples R China
来源:
基金:
中国国家自然科学基金;
关键词:
vertical permeability heterogeneity;
reservoir permeability;
enhanced geothermal system;
electricity generation performance;
Yangbajing geothermal field;
FRACTURED GRANITE RESERVOIR;
3-DIMENSIONAL TRANSIENT MODEL;
HOT DRY ROCK;
NUMERICAL-SIMULATION;
HEAT EXTRACTION;
HORIZONTAL WELLS;
SONGLIAO BASIN;
COUPLED MODEL;
EGS;
ENERGY;
D O I:
10.3390/pr9050744
中图分类号:
TQ [化学工业];
学科分类号:
0817 ;
摘要:
Because geologic sedimentation and hydrofracturing processes are not homogeneous, the reservoirs of enhanced geothermal systems (EGSs) are also heterogeneous; this has a significant influence on the electricity generation performance of EGS. Presently, there are a lack of systematic and profound studies on the effect of vertical permeability heterogeneity in stratified formation on the electricity generation performance of EGS. In order to uncover the effect of vertical permeability heterogeneity on electricity generation performance of EGS, in this work we analyzed the influence of vertical permeability heterogeneity on electricity generation performance of EGS through a numerical method based on geological data at the Yangbajing geothermal field. The results indicate that when the average permeability of stratified formations is constant for a homogeneous reservoir, the system attains maximum water production rate, maximum electric power, minimum reservoir impedance and maximum pump power; with the increasing of the vertical permeability heterogeneity, the water production rate gradually decreases, the electric power gradually declines, the reservoir impedance gradually increases and the pump power gradually declines. When the average permeability of stratified formations is constant, with the increasing of the vertical permeability heterogeneity, the injection pressure and energy efficiency only changes very slightly; this indicates that the vertical permeability heterogeneity is not the main factor affecting the system injection pressure and energy efficiency.