A fast bioluminescent source localization method based on generalized graph cuts with mouse model validations

被引:30
|
作者
Liu, Kai [1 ]
Tian, Jie [1 ,2 ]
Lu, Yujie [3 ]
Qin, Chenghu [1 ]
Yang, Xin [1 ]
Zhu, Shouping [1 ]
Zhang, Xing [1 ]
机构
[1] Chinese Acad Sci, Inst Automat, Med Image Proc Grp, Beijing 100190, Peoples R China
[2] Xidian Univ, Life Sci Ctr, Xian 710071, Shaanxi, Peoples R China
[3] Univ Calif Los Angeles, David Geffen Sch Med, Dept Mol & Med Pharmacol, Crump Inst Mol Imaging, Los Angeles, CA 90095 USA
来源
OPTICS EXPRESS | 2010年 / 18卷 / 04期
基金
中国国家自然科学基金;
关键词
IMAGE-RECONSTRUCTION; OPTICAL TOMOGRAPHY; LIGHT; SIMULATION;
D O I
10.1364/OE.18.003732
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Bioluminescence imaging (BLI) makes it possible to elucidate molecular and cellular signatures to better understand the effects of human disease in small animal models in vivo. The unambiguous three-dimensional bioluminescent source information obtained by bioluminescence tomography (BLT) could further facilitate its applications in biomedicine. However, to the best of our knowledge, the existing gradient-type reconstruction methods in BLT are inefficient, and often require a relatively small volume of interest (VOI) for feasible results. In this paper, a fast generalized graph cuts based reconstruction method for BLT is presented, which is to localize the bioluminescent source in heterogeneous mouse tissues via max-flow/min-cut algorithm. Since the original graph cuts theory can only handle graph-representable problem, the quadratic pseudo-boolean optimization is incorporated to make the graph representable and tractable, which is called generalized graph cuts (GGC). The internal light source can be reconstructed from the whole domain, so a priori knowledge of VOI can be avoided in this method. In the simulation validations, the proposed method was validated in a heterogeneous mouse atlas, and the source can be localized reliably and efficiently by GGC; and compared with gradient-type method, the proposed method is about 25-50 times faster. Moreover, the experiments for sensitivity to the measurement errors of tissue optical properties demonstrate that, the reconstruction quality is not much affected by mismatch of parameters. In what follows, in vivo mouse BLT reconstructions further demonstrated the potential and effectiveness of the generalized graph cut based reconstruction method. (C) 2010 Optical Society of America
引用
收藏
页码:3732 / 3745
页数:14
相关论文
共 50 条
  • [1] FAST LOCALIZE THE BIOLUMINESCENT SOURCE VIA GRAPH CUTS
    Liu, Kai
    Tian, Jie
    Zhu, Shouping
    Qin, Chenghu
    Zhang, Xing
    Han, Dong
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 696 - 699
  • [2] Fast method of motion segmentation based on graph cuts
    Hou, Ye
    Guo, Bao-Long
    Xi Tong Gong Cheng Yu Dian Zi Ji Shu/Systems Engineering and Electronics, 2009, 31 (12): : 2998 - 3001
  • [3] A Novel Fast Liver Segmentation Method with Graph Cuts
    Yang, Fan
    Zhai, Weiming
    Zhao, Yannan
    Wang, Hong
    Jia, Peifa
    MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623
  • [4] A multilevel banded graph cuts method for fast image segmentation
    Lombaert, H
    Sun, YY
    Grady, L
    Xu, CY
    TENTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS 1 AND 2, PROCEEDINGS, 2005, : 259 - 265
  • [5] Fast adaptive graph-cuts based stereo matching
    Sarkis, Michel
    Doerfler, Nikolas
    Diepold, Klaus
    ADVANCED CONCEPTS FOR INTELLIGENT VISION SYSTEMS, PROCEEDINGS, 2007, 4678 : 818 - 827
  • [6] A graph-based narrowband matched-field source localization method
    Xiao, Peng
    Yang, Jianmin
    JASA EXPRESS LETTERS, 2021, 1 (12):
  • [7] A new image thresholding method based on graph cuts
    Tao, Wenbing
    Jin, Hai
    Liu, Liman
    2007 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOL I, PTS 1-3, PROCEEDINGS, 2007, : 605 - +
  • [8] PGSL: A probabilistic graph diffusion model for source localization
    Xu, Xovee
    Qian, Tangjiang
    Xiao, Zhe
    Zhang, Ni
    Wu, Jin
    Zhou, Fan
    EXPERT SYSTEMS WITH APPLICATIONS, 2024, 238
  • [9] Fast stereo matching algorithm based on adaptive window and graph cuts
    Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
    不详
    不详
    Guangxue Jingmi Gongcheng, 2008, 6 (1117-1121):
  • [10] Fast moving sound source localization method based on time difference of arrival
    Yang, Diange
    Zhang, Kai
    Miao, Feng
    Wen, Junjie
    Lian, Xiaomin
    Shengxue Xuebao/Acta Acustica, 2020, 45 (01): : 69 - 76