Quantitative ultrasound and dual X-ray absorptiometry measurements of the calcaneus in patients on maintenance hemodialysis

被引:33
|
作者
Peretz, A
Penaloza, A
Mesquita, M
Dratwa, M
Verhas, M
Martin, P
De Maertelaer, V
Bergmann, P
机构
[1] CHU Brugmann, Dept Internal Med, Clin Rheumatol, Dialysis Ctr, B-1020 Brussels, Belgium
[2] CHU Brugmann, Nucl Med Lab, Brussels, Belgium
[3] Free Univ Brussels, IRIBHN, Brussels, Belgium
关键词
hemodialysis; quantitative ultrasound; calcaneus; dual X-ray absorptiometry; hyperparathyroidism; regression lines;
D O I
10.1016/S8756-3282(00)00320-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
It has been suggested that quantitative ultrasound measurements (QUS), which reflect mainly bone density, could be influenced by bone micro-architecture. The aim of the study was to assess whether the relationship of QUS to dual X-ray absorptiometry (DXA) would reflect abnormalities of hone structure observed in renal osteodystrophy. QUS and bone mineral density of the calcancus (BMDc) were measured by DXA in 30 patients on maintenance hemodialysis and 34 age- and gender-matched controls. QUS parameters and BMDc were significantly lower in hemodialysis patients than in controls (speed of sound [SOS] and broadband ultrasound attenuation [BUA], p = 0.030; stiffness, p = 0.003; BMDc, p = 0.006), Bone measurements were not correlated with serum parathyroid hormone (PTH). The regression lines of SOS, BUA, and stiffness to BMDe were not significantly different from that of the controls, When dividing the patients into two subgroups according to their median PTA (203 pg/mL), the slopes of the regression lines of BUA to BMDe were significantly different between these two subgroups (p = 0.052). The slope of the subgroup with PTH less than or equal to 203 pg/mL, was significantly different from that of the controls (p = 0.030). In conclusion, QUS of the calcaneus can be used for bone assessment in patients on maintenance hemodialysis. The differences in the slopes of patients with a less pronounced degree of hyperparathyroidism compared with patients with a higher degree of hyperparathyroidism and to controls suggest that BUA of the calcaneus contains information on bone complementary to DXA measured at the same site. The clinical relevance of this finding is presently unclear. (C) 2000 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:287 / 292
页数:6
相关论文
共 50 条
  • [1] Comparison of ultrasound and dual energy X-ray absorptiometry measurements in the calcaneus
    Kang, C
    Speller, R
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (848): : 861 - 867
  • [2] Quantitative ultrasound of the radius and calcaneus: a comparison with dual-energy X-ray absorptiometry
    Boyanov, M.
    Shinkov, A.
    Nestorova, R.
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2007, 132 (16) : 869 - 873
  • [3] Discrimination of hip fractures by quantitative ultrasound of the phalanges and the calcaneus and dual X-ray absorptiometry
    Damilakis, J
    Papadokostakis, G
    Pertsinakis, K
    Maris, T
    Dimitriou, P
    Hadjipavlou, A
    Gourtsoyiannis, N
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2004, 50 (03) : 268 - 272
  • [4] A Comparison of Quantitative Ultrasound of the Calcaneus With Dual-Energy X-ray Absorptiometry in Hospitalized Orthopaedic Trauma Patients
    Collinge, Cory A.
    Lebus, George
    Gardner, Michael J.
    Gehrig, Laura
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (03) : 176 - 180
  • [5] Dual X-ray and laser absorptiometry of the calcaneus
    Martini, G
    Valenti, R
    Gennari, L
    Salvadori, S
    Galli, B
    Nuti, R
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2004, 7 (03) : 349 - 354
  • [6] Comparison of calcaneus ultrasound and dual X-ray absorptiometry in children at risk of osteopenia
    Fielding, KT
    Nix, DA
    Bachrach, LK
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2003, 6 (01) : 7 - 15
  • [7] Evaluation of quantitative ultrasound and dual X-ray absorptiometry measurements in women with and without fractures
    Peretz, A
    De Maertelaer, V
    Moris, M
    Wouters, M
    Bergmann, P
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 1999, 2 (02) : 127 - 133
  • [8] Quantitative ultrasound of the calcaneus - An in vivo comparison with dual-energy X-ray absorptiometry and magnetic resonance imaging
    Louis, O
    Allein, S
    Luypaert, R
    Osteaux, M
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2000, 3 (01) : 43 - 48
  • [9] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18
  • [10] MEASUREMENT OF THE CALCANEUS BY ULTRASOUND AND DUAL-ENERGY X-RAY ABSORPTIOMETRY IN POSTMENOPAUSAL OSTEOPOROSIS
    NAYLOR, KE
    LANGTON, CM
    SMITH, TWD
    EASTELL, R
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 : S353 - S353