Effects of gait support in patients with spinocerebellar degeneration by a wearable robot based on synchronization control

被引:11
|
作者
Tsukahara, Atsushi [1 ,2 ]
Yoshida, Kunihiro [3 ,4 ]
Matsushima, Akira [5 ]
Ajima, Kumiko [4 ]
Kuroda, Chika [6 ]
Mizukami, Noriaki [1 ]
Hashimoto, Minoru [1 ,2 ]
机构
[1] Shinshu Univ, Fac Text Sci & Technol, Dept Mech Engn & Robot, 3-15-1 Tokida, Ueda, Nagano 3868567, Japan
[2] Shinshu Univ, ICCER, Inst Fiber Engn IFES, Ueda, Nagano, Japan
[3] Shinshu Univ, Sch Med, Dept Brain Dis Res, 3-1-1 Asahi, Matsumoto, Nagano 3908621, Japan
[4] Shinshu Univ, ICCER, IBS, Matsumoto, Nagano, Japan
[5] Kakeyu Hosp, Kakeyu Misayama Rehabil Ctr, 1308 Kakeyu, Ueda, Nagano 3860396, Japan
[6] Shinshu Univ, Grad Sch Med, Dept Hlth Sci, 3-1-1 Asahi, Matsumoto, Nagano 3908621, Japan
基金
日本学术振兴会;
关键词
Spinocerebellar degeneration; Gait support; Synchronization control; CENTRAL PATTERN GENERATOR; ACCELERATION PATTERNS; NEURAL OSCILLATORS; HARMONIC RATIOS; WALKING; ATAXIA; EXOSKELETON; ASSISTANCE; STABILITY; MOVEMENTS;
D O I
10.1186/s12984-018-0425-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Spinocerebellar degeneration (SCD) mainly manifests a cerebellar ataxic gait, leading to marked postural sway and the risk of falling down. Gait support using a wearable robot is expected to be an effective solution to maintaining the status quo and/or delaying symptom progression. The aim of this study was to evaluate the effects of gait support in patients with SCD by using a wearable robotic system called curara (R) while undergoing walking tests. Methods: The curara system assists both the hip and knee joints and supports the wearer's rhythmic gait using a synchronization control based on a central pattern generator. The system reflects the wearer's intended motion in response to the gait support by detecting an interactive force that is generated from slight movements of the wearer. The degree of coordinated motion between the robot and the wearer can be adjusted by modifying the synchronization gain. In this study, we provided gait support using three high-gain conditions (A, B, C) to more easily follow the wearer's movement in each joint. The synchronization gains for both the hip and knee joints (i.e., C-h and C-k) were set at 0.5 for condition A and at 0.4 for condition B. Condition C had different gains for the hip and knee joints (i.e., C-h=0.4 and C-k=0.5). With the walking test, we assessed the effects of the gait support provided by the curara system on walking smoothness (measured using the harmonic ratio: HR) and spatiotemporal parameters (gait speed, stride length, cadence) in SCD patients (n=12). We compared the performance between the three high-gain conditions and without assistance from the robot. Results: Under condition C, the HRs in the anteroposterior, mediolateral, and vertical directions (HR-AP, HR-ML, and HR-V) were especially high compared with those under conditions A and B. The results of the statistical analyses using repeated measures analysis of variance followed by Tukey's test showed that gait support with condition C results in a statistically significant increase in the HR-AP (2.04 +/- 0.52; p=0.025) and HR-V (2.06 +/- 0.37; p=0.032) when compared with walking without assistance from the system. In contrast, the gait speed, stride length, and cadence under condition C were no major changes in most patients, compared with the patient's walking without assistance. Conclusions: The significantly increased HR indicates that gait support under condition C achieved smoother walking than when not wearing the power unit of the system. Consequently, we suggest that gait support using the curara system has the potential to improve walking smoothness in patients with SCD.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Effects of gait support in patients with spinocerebellar degeneration by a wearable robot based on synchronization control
    Atsushi Tsukahara
    Kunihiro Yoshida
    Akira Matsushima
    Kumiko Ajima
    Chika Kuroda
    Noriaki Mizukami
    Minoru Hashimoto
    Journal of NeuroEngineering and Rehabilitation, 15
  • [2] Wearable gait sensors to measure ataxia due to spinocerebellar degeneration
    Terayama, Keiichiro
    Sakakibara, Ryuji
    Ogawa, Akihiro
    NEUROLOGY AND CLINICAL NEUROSCIENCE, 2018, 6 (01): : 9 - 12
  • [3] Effect of the Synchronization-Based Control of a Wearable Robot Having a Non-Exoskeletal Structure on the Hemiplegic Gait of Stroke Patients
    Mizukami, Noriaki
    Takeuchi, Shizue
    Tetsuya, Mikio
    Tsukahara, Atsushi
    Yoshida, Kunihiro
    Matsushima, Akira
    Maruyama, Yoichi
    Tako, Kenji
    Hashimoto, Minoru
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2018, 26 (05) : 1011 - 1016
  • [4] Pilot Study of Single-Legged Walking Support using Wearable Robot based on Synchronization Control for Stroke Patients
    Tsukahara, Atsushi
    Hashimoto, Minoru
    2016 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2016, : 886 - 891
  • [5] Temporal integration in sensorimotor synchronization in patients with spinocerebellar degeneration
    Matsuda, S.
    Furubayashi, T.
    Fukuda, H.
    Hanajima, R.
    Tsuji, S.
    Ugawa, Y.
    Terao, Y.
    MOVEMENT DISORDERS, 2013, 28 : S259 - S259
  • [6] Effects of gait training using the Hybrid Assistive Limb (HAL®) in patients with spinocerebellar degeneration
    Nakamura, Y.
    Ueno, S.
    Hamada, M.
    Hirano, M.
    Touge, T.
    EUROPEAN JOURNAL OF NEUROLOGY, 2018, 25 : 463 - 463
  • [7] New corrective shoes to improve ataxic gait of patients with spinocerebellar degeneration
    Ando, N
    Ando, M
    Mano, Y
    Takayanagi, T
    Ueno, S
    ELECTROPHYSIOLOGY AND KINESIOLOGY, 2000, : 207 - 214
  • [8] Effects of Robot-Assisted Gait Training with Body Weight Support on Gait and Balance in Stroke Patients
    Choi, Wonho
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (10)
  • [9] Evaluation of Walking Smoothness using Wearable Robotic System curara® for Spinocerebellar Degeneration Patients
    Tsukahara, Atsushi
    Yoshida, Kunihiro
    Matsushima, Akira
    Ajima, Kumiko
    Kuroda, Chika
    Mizukami, Noriaki
    Hashimoto, Minoru
    2017 INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2017, : 1494 - 1499
  • [10] Effect of different gait phase-based assist patterns of a wearable robot on gait motion
    Kondo, Kiichi
    Akiyama, Yasuhiro
    Okamoto, Shogo
    Yamada, Yoji
    2021 IEEE INTERNATIONAL CONFERENCE ON INTELLIGENCE AND SAFETY FOR ROBOTICS (ISR), 2021, : 378 - 381