Effects of Hounsfield number conversion on CT based proton Monte Carlo dose calculations

被引:67
|
作者
Jiang, Hongyu [1 ]
Seco, Joao [1 ]
Paganetti, Harald [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
关键词
Geant4; Monte Carlo; proton therapy; CT Hounsfield conversion;
D O I
10.1118/1.2715481
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Monte Carlo method provides the most accurate dose calculations on a patient computed tomography (CT) geometry. The increase in accuracy is, at least in part, due to the fact that instead of treating human tissues as water of various densities as in analytical algorithms, the Monte Carlo method allows human tissues to be characterized by elemental composition and mass density, and hence allows the accurate consideration of all relevant electromagnetic and nuclear interactions. On the other hand, the algorithm to convert CT Hounsfield numbers to tissue materials for Monte Carlo dose calculation introduces uncertainties. There is not a simple one to one correspondence between Hounsfield numbers and tissue materials. To investigate the effects of Hounsfield number conversion for proton Monte Carlo dose calculations, clinical proton treatment plans were simulated using the Geant4 Monte Carlo code. Three Hounsfield number to material conversion methods were studied. The results were compared in forms of dose volume histograms of gross tumor volume and clinical target volume. The differences found are generally small but can be dosimetrically significant. Further, different methods may cause deviations in the predicted proton beam range in particular for deep proton fields. Typically, slight discrepancies in mass density assignments play only a minor role in the target region, whereas more significant effects are caused by different assignments in elemental compositions. In the presence of large tissue inhomogeneities, for head and neck treatments, treatment planning decisions could be affected by these differences because of deviations in the predicted tumor coverage. Outside the target area, differences in elemental composition and mass density assignments both may play a role. This can lead to pronounced effects for organs at risk, in particular in the spread-out Bragg peak penumbra or distall regions. In addition, the significance of the elemental composition effect (dose to water vs. dose to tissue) is tissue-type dependent and is also affected by nuclear reactions. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1439 / 1449
页数:11
相关论文
共 50 条
  • [1] Dependency of Proton Dose On Tissue Composition Investigated Using Monte Carlo Models of Hounsfield Number Conversion and Cadaver-Based Anatomical Data
    Liu, Y.
    Shi, C.
    Xu, X.
    Chen, W.
    Jette, D.
    Papanikolaou, N.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [2] Conversion of CT numbers into tissue parameters for Monte Carlo dose calculations
    Vanderstraeten, B
    Born, E
    Fippel, M
    Leal, A
    Mora, G
    Reynaert, N
    Seco, J
    Soukup, M
    Spezi, E
    De Smedt, B
    De Bisschop, F
    De Neve, W
    Thierens, H
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S46 - S47
  • [3] Effect of CT conversion on Monte Carlo dose calculations for head and neck treatments
    Mora, G
    Li, JS
    Wang, L
    Ding, M
    Yang, J
    Ma, CM
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1452 - 1452
  • [4] CTCASK; A NEW ALGORITHM FOR CONVERSION OF CT TO TISSUE PARAMETERS FOR MONTE CARLO DOSE CALCULATIONS
    Ottosson, R. O.
    Behrens, C. F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S515 - S516
  • [5] CT-based Monte Carlo Dose Calculations for Prostate Implants
    Chibani, O.
    Hassan, Z.
    Moftah, B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S751 - S751
  • [6] Tissue Composition Effect Investigated in Proton Therapy using Monte Carlo Models of Hounsfield Number Conversion and Cadaver-based Anatomical Data
    Liu, Y.
    Shi, C.
    Chen, W.
    Xu, G.
    Papanikolaou, N.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S701 - S701
  • [7] Monte Carlo dose calculations for spot scanned proton therapy
    Tourovsky, A
    Lomax, AJ
    Schneider, U
    Pedroni, E
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (05): : 971 - 981
  • [8] Monte Carlo and analytical dose calculations for proton spot scanning
    Bues, M
    Ciangaru, G
    Smith, A
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1902 - 1903
  • [9] Automatic Monte Carlo Dose Calculations of Proton Treatment Plans
    Titt, U.
    Mirkovic, D.
    Liu, A.
    Mohan, R.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3805 - 3805
  • [10] Monte Carlo Based Multidetector CT Modeling and Dose Calculations for Pregnant Patients
    Gu, J.
    Caracappa, P.
    Xu, X.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)