A head-to-head comparison of the degradation rate of resorbable bioceramics

被引:22
|
作者
Hsu, Pei-Yi [1 ]
Kuo, Hsiao-Chun [1 ]
Syu, Man-Lin [1 ]
Tuan, Wei-Hsing [1 ]
Lai, Po-Liang [2 ]
机构
[1] Natl Taiwan Univ, Dept Mat Sci & Engn, Taipei 106, Taiwan
[2] Chang Gung Univ, Coll Med, Chang Gung Mem Hosp Linkou, Dept Orthoped Surg,Bone & Joint Res Ctr, Taoyuan 333, Taiwan
关键词
Tricalcium phosphate; Calcium sulfate; Bioceramics; Resorbable materials; In vitro degradation; CALCIUM-SULFATE; BONE SUBSTITUTE; HYDROXYAPATITE; DECOMPOSITION; PHOSPHATE; GRAFT;
D O I
10.1016/j.msec.2019.110175
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Resorbable bioceramics offer advantages in healing bone defects due to their degradation capability. Degradation rates differ significantly from one bioceramic to another; nevertheless, the degradation rate should match the growth rate of new bone. In the present study, a head-to-head comparison of the degradation rate of calcium sulfate and tricalcium phosphate is conducted. First, the degradation behaviors of calcium sulfate and tricalcium phosphate are evaluated separately. The comparison indicates that the degradation rate of calcium sulfate is one order of magnitude faster than that of tricalcium phosphate. Along with a fast degradation rate, the formation of calcium phosphate on the surface of calcium sulfate pellets is also faster. A core-shell roll composed of a calcium sulfate core and a tricalcium phosphate shell is also prepared. After soaking the core-shell roll in phosphate buffered saline solution for 24 h, calcium phosphate precipitates form only on the surface of core, the part containing calcium sulfate anhydrite.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] PREPARATION AND DEGRADATION OF HEAD-TO-HEAD PVC
    CRAWLEY, S
    MCNEILL, IC
    JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1978, 16 (10) : 2593 - 2606
  • [2] HEAD-TO-HEAD POLYMERS .27. THERMAL-DEGRADATION OF HEAD-TO-HEAD POLYISOBUTYLENE
    MALANGA, M
    XI, F
    VOGL, O
    POLYMER ENGINEERING AND SCIENCE, 1983, 23 (04): : 226 - 229
  • [3] HEAD-TO-HEAD COMPARISON OF RISEDRONATE AND ALENDRONATE
    Christiansen, C.
    Phipps, R.
    Burgio, D.
    Sun, L.
    Russell, D.
    Keck, B.
    Kuzmak, B.
    Lindsay, R.
    CALCIFIED TISSUE INTERNATIONAL, 2004, 74 : S36 - S37
  • [4] Head-to-head IUS comparison needed
    Plante, Sarah C.
    CANADIAN FAMILY PHYSICIAN, 2022, 68 (10) : 717 - +
  • [5] Head-to-head comparison of serum fractionation techniques
    Whiteaker, Jeffrey R.
    Zhang, Heidi
    Eng, Jimmy K.
    Fang, Ruihua
    Piening, Brian D.
    Feng, Li-Chia
    Lorentzen, Travis D.
    Schoenherr, Regine M.
    Keane, John F.
    Holzman, Ted
    Fitzgibbon, Matthew
    Lin, ChenWei
    Zhang, Hui
    Cooke, Kelly
    Liu, Tao
    Camp, David G., II
    Anderson, Leigh
    Watts, Julian
    Smith, Richard D.
    McIntosh, Martin W.
    Paulovich, Amanda G.
    JOURNAL OF PROTEOME RESEARCH, 2007, 6 (02) : 828 - 836
  • [6] Head-to-head comparison of pandemic influenza vaccines
    Leroux-Roels, Geert
    Leroux-Roels, Isabel
    LANCET INFECTIOUS DISEASES, 2011, 11 (02): : 74 - 75
  • [7] HEAD-TO-HEAD POLYMERS .7. COMPARISON OF HEAD-TO-HEAD AND HEAD-TO-TAIL POLYSTYRENES BY THERMALLY STIMULATED DISCHARGE
    MARCHAL, E
    BENOIT, H
    VOGL, O
    JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 1978, 16 (06) : 949 - 958
  • [8] HEAD-TO-HEAD POLYMERS .14. THERMAL-DEGRADATION OF HEAD-TO-HEAD AND HEAD-TO-TAIL POLYSTYRENES AND POLY(VINYLCYCLOHEXANE)S
    LUDERWALD, I
    VOGL, O
    MAKROMOLEKULARE CHEMIE-MACROMOLECULAR CHEMISTRY AND PHYSICS, 1979, 180 (10): : 2295 - 2302
  • [10] Relapsing MS: Head-to-head comparison of rituximab and ocrelizumab
    Kessing, Richard
    FORTSCHRITTE DER NEUROLOGIE PSYCHIATRIE, 2024, 92 (03) : 68 - 69