Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy

被引:4
|
作者
Ozseven, Alper [1 ]
Dirican, Bahar [2 ]
机构
[1] Suleyman Demirel Univ, Med Fac, Isparta, Turkey
[2] Univ Hlth Sci, Gulhane Med Fac, Ankara, Turkey
关键词
kV CBCT; equivalent organ dose; effective dose; image guided radiation therapy; Alderson Rando phantom; GUIDED RADIOTHERAPY; CANCER; EXPOSURE;
D O I
10.5603/RPOR.a2021.0038
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Currently, CBCT system is an indispensable component of radiation therapy units. Because of that, it is important in treatment planning and diagnosis. CBCT is also an crucial tool for patient positioning and verification in image-guided radiation therapy (IGRT). Therefore, it is critical to investigate the patient organ doses arising from CBCT imaging.The purpose of this study is to evaluate patient organ doses and effective dose to patients from three different protocols of Elekta Synergy XVI system for kV CBCT imaging examinations in image guided radiation therapy. Materials and methods: Organ dose measurements were done with thermoluminescent dosimeters in Alderson RANDO male phantom for head & neck (H&N), chest and pelvis protocols of the Elekta Synergy XVI kV CBCT system. From the measured organ dose, effective dose to patients were calculated according to the International Commission on Radiological Protection 103 report recommendations. Results: For H&N, chest and pelvis scans, the organ doses were in the range of 0.03-3.43 mGy, 6.04-22.94 mGy and 2.5-25.28 mGy, respectively. The calculated effective doses were 0.25 mSv, 5.56 mSv and 4.72 mSv, respectively. Conclusion: The obtained results were consistent with the most published studies in the literature. Although the doses to patient organs from the kV CBCT system were relatively low when compared with the prescribed treatment dose, the amount of delivered dose should be monitored and recorded carefully in order to avoid secondary cancer risk, especially in pediatric examinations.
引用
收藏
页码:251 / 258
页数:8
相关论文
共 50 条
  • [1] IMAGING DOSES AND SECONDARY CANCER RISK FROM KILOVOLTAGE CONE-BEAM CT IN RADIATION THERAPY
    Kim, Dong Wook
    Chung, Weon Kuu
    Yoon, Myonggeun
    [J]. HEALTH PHYSICS, 2013, 104 (05): : 499 - 503
  • [2] Organ Doses From Cone-Beam CT in Radiation Therapy
    Hyer, D.
    Hintenlang, D.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2437 - +
  • [3] Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy
    Ding, George X.
    Duggan, Dennis M.
    Coffey, Charles W.
    [J]. MEDICAL PHYSICS, 2008, 35 (03) : 1135 - 1144
  • [4] Estimation of organ doses from kilovoltage cone-beam CT imaging used during radiotherapy patient position verification
    Hyer, Daniel E.
    Hintenlang, David E.
    [J]. MEDICAL PHYSICS, 2010, 37 (09) : 4620 - 4626
  • [5] Evaluation of Patient Dose Reduction in Kilovoltage Cone-beam CT for Image-guided Radiation Therapy
    Noto, K.
    Ueda, S.
    Syouji, S.
    Hori, N.
    Kurata, Y.
    Yamamoto, T.
    Takemura, A.
    Matsubara, K.
    Koshida, K.
    Takamatsu, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S742 - S742
  • [6] Beam characteristics and radiation output of a kilovoltage cone-beam CT
    Ding, George X.
    Coffey, Charles W.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17): : 5231 - 5248
  • [7] Accurate Image Reconstruction From Incomplete Kilovoltage Cone-Beam CT Data in Radiation Therapy
    Han, X.
    Bian, J.
    Cho, S.
    Sidky, E.
    Pearson, E.
    Pelizzari, C.
    Pan, X.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2445 - +
  • [8] Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy
    Islam, Mohammad K.
    Purdie, Thomas G.
    Norrlinger, Bernhard D.
    Alasti, Hamideh
    Moseley, Douglas J.
    Sharpe, Michael B.
    Siewerdsen, Jeffrey H.
    Jaffray, David A.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 1573 - 1582
  • [9] Validation of a technique for estimating organ doses for kilovoltage cone-beam CT of the prostate using the PCXMC 2.0 patient dose calculator
    Wood, T. J.
    Moore, C. S.
    Saunderson, J. R.
    Beavis, A. W.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2015, 35 (01) : 153 - 163
  • [10] Quality assurance program for a kilovoltage cone-beam CT guided radiation therapy system
    Wang, Y. Y.
    Fu, X. L.
    Xu, Z. Y.
    Hu, W. G.
    Jiang, G. L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S719 - S720