Remote Magnetic Navigation: A Focus on Catheter Ablation of Ventricular Arrhythmias

被引:12
|
作者
Aagaard, Philip [1 ]
Natale, Andrea [2 ,4 ,5 ,6 ,7 ,8 ,9 ]
Briceno, David [1 ]
Nakagawa, Hiroshi [10 ]
Mohanty, Sanghamitra [2 ]
Gianni, Carola [2 ]
Burkhardt, J. David [2 ]
Di Biase, Luigi [1 ,2 ,3 ,4 ]
机构
[1] Montefiore Med Ctr, Albert Einstein Coll Med, Montefiore Einstein Ctr Heart & Vasc Care, 111 East 210th St, Bronx, NY 10467 USA
[2] St Davids Med Ctr, Texas Cardiac Arrhythmia Inst, Austin, TX USA
[3] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
[4] Univ Foggia, Dept Cardiol, Foggia, Italy
[5] Stanford Univ, Div Cardiol, Stanford, CA 94305 USA
[6] Case Western Reserve Univ, Cleveland, OH 44106 USA
[7] Calif Pacific Med Ctr, EP Serv, San Francisco, CA USA
[8] Scripps Clin, Intervent Electrophysiol, San Diego, CA USA
[9] Univ Texas Austin, Dell Med Sch, Austin, TX 78712 USA
[10] Univ Oklahoma, Hlth Sci Ctr, Heart Rhythm Inst, Oklahoma City, OK USA
关键词
catheter ablation; remote magnetic navigation; Stereotaxis; ventricular tachycardia; ATRIAL-FIBRILLATION ABLATION; INITIAL CLINICAL-EXPERIENCE; OUTFLOW TRACT TACHYCARDIA; IRRIGATED-TIP CATHETER; RADIOFREQUENCY ABLATION; EPICARDIAL ABLATION; ELECTRICAL STORM; CONTACT FORCE; SYSTEM; EFFICACY;
D O I
10.1111/jce.12938
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A Focus on Catheter Ablation of Ventricular Arrhythmias VT ablation is based on percutaneous catheter insertion under fluoroscopic guidance to selectively destroy (i.e., ablate) myocardial tissue regions responsible for the initiation or propagation of ventricular arrhythmias. Although the last decade has witnessed a rapid evolution of ablation equipment and techniques, the control over catheter movement during manual ablation has remained largely unchanged. Moreover, the procedures are long, and require ergonomically unfavorable positions, which can lead to operator fatigue. In an attempt to overcome these constraints, several technical advancements, including remote magnetic navigation (RMN), have been developed. RMN utilizes a magnetic field to remotely manipulate specially designed soft-tip ablation catheters anywhere in the x, y, or z plane inside the patient's chest. RMN also facilitates titration of the contact force between the catheter and the myocardial tissue, which may reduce the risk of complications while ensuring adequate lesion formation. There are several non-randomized studies showing that RMN has similar efficacy to manual ablation, while complication rates and total radiation exposure appears to be lower. Although these data are promising, larger randomized studies are needed to prove that RMN is superior to manual ablation of VT.
引用
收藏
页码:S38 / S44
页数:7
相关论文
共 50 条
  • [1] Remote magnetic navigation compared to contemporary manual techniques for the catheter ablation of ventricular arrhythmias in structural heart disease
    Bennett, Richard G.
    Campbell, Timothy
    Sood, Ashish
    Bhaskaran, Ashwin
    De Silva, Kasun
    Davis, Lloyd
    Qian, Pierre
    Sivagangabalan, Gopal
    Cooper, Mark J.
    Chow, Clara K.
    Thiagalingam, Aravinda
    Denniss, A. Robert
    Thomas, Stuart P.
    Kizana, Eddy
    Kumar, Saurabh
    HELIYON, 2021, 7 (12)
  • [2] Long-Term Efficacy and Impact on Mortality of Remote Magnetic Navigation Guided Catheter Ablation of Ventricular Arrhythmias
    Guckel, Denise
    Niemann, Sarah
    Ditzhaus, Marc
    Molatta, Stephan
    Bergau, Leonard
    Fink, Thomas
    Sciacca, Vanessa
    El Hamriti, Mustapha
    Imnadze, Guram
    Steinhauer, Philipp
    Braun, Martin
    Khalaph, Moneeb
    Noelker, Georg
    Sommer, Philipp
    Sohns, Christian
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (20)
  • [3] Usefulness of remote magnetic navigation for ablation of ventricular arrhythmias originating from outflow regions
    Schwagten, B. K. R.
    Szili-Torok, T.
    Rivero-Ayerza, M.
    Jessurun, E.
    Valk, S.
    Jordaens, L. J. L. M.
    NETHERLANDS HEART JOURNAL, 2009, 17 (06) : 245 - 249
  • [4] Usefulness of remote magnetic navigation for ablation of ventricular arrhythmias originating from outflow regions
    B. K. R. Schwagten
    T. Szili-Torok
    M. Rivero-Ayerza
    E. Jessurun
    S. Valk
    L. J. L. M. Jordaens
    Netherlands Heart Journal, 2009, 17 : 245 - 249
  • [5] Remote magnetic navigation for mapping and ablation of right and left ventricular outflow tract arrhythmias
    Parreira, Leonor
    Cavaco, Diogo
    Reis-Santos, Katya
    Carmo, Pedro
    Cabrita, David
    Scanavacca, Mauricio
    Adragao, Pedro
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2013, 32 (06) : 489 - 495
  • [6] Catheter ablation of ventricular arrhythmias with the remote magnetic navigation system and the 3.5 mm open irrigated magnetic catheter: results from a large single center seires
    Di Biasel, L.
    Santangeli, P.
    Astudillo, V.
    Conti, S.
    Mohanty, P.
    Mohanty, M.
    Sanchez, J. E.
    Horton, R.
    Thomas, B.
    Natale, A.
    EUROPEAN HEART JOURNAL, 2010, 31 : 562 - 562
  • [7] Initial experience with remote catheter ablation using a novel magnetic navigation system -: Magnetic remote catheter ablation
    Ernst, S
    Ouyang, FF
    Linder, C
    Hertting, K
    Stahl, F
    Chun, J
    Hachiya, H
    Bänsch, D
    Antz, M
    Kuck, KH
    CIRCULATION, 2004, 109 (12) : 1472 - 1475
  • [8] OUTCOMES OF REMOTE MAGNETIC NAVIGATION-GUIDED CATHETER ABLATION OF LEFT VENTRICULAR SUMMIT ARRHYTHMIAS ACCESSIBLE VIA THE CORONARY VENOUS SYSTEM
    Bassil, Guillaume
    Saleh, Layth
    Markowitz, Steven
    Liu, Christopher
    Thomas, George
    Ip, James
    Lerman, Bruce
    Cheung, Jim
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 495 - 495
  • [9] Catheter Ablation for Ventricular Arrhythmias
    Nof, Eyal
    Stevenson, William G.
    John, Roy M.
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2013, 2 (01) : 45 - 52
  • [10] Catheter Ablation of Ventricular Arrhythmias
    Shivkumar, Kalyanam
    NEW ENGLAND JOURNAL OF MEDICINE, 2019, 380 (16): : 1555 - 1564