High-resolution magnetic resonance imaging of the triangular fibrocartilage complex using compressed sensing sensitivity encoding (SENSE)

被引:4
|
作者
Fujiwara, Hiroki [1 ]
Yabuuchi, Hidetake [1 ]
Wada, Tatsuhiro [2 ]
Kobayashi, Kouji [2 ]
Hoshuyama, Toko [1 ]
Kamitani, Takeshi [3 ]
Ishigami, Kousei [3 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Hlth Sci, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
[2] Kyushu Univ Hosp, Dept Med Technol, Div Radiol, Fukuoka, Japan
[3] Kyushu Univ, Grad Sch Med Sci, Dept Clin Radiol, Fukuoka, Japan
关键词
High-resolution; Magnetic resonance imaging (MRI); Compressed sensing; Sensitivity encoding (SENSE); Triangular fibro cartilage complex (TFCC); MRI; ARTHROSCOPY; WRIST; TFCC;
D O I
10.1016/j.ejrad.2022.110191
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the optimal sequence for high-resolution magnetic resonance imaging (MRI) of the trian-gular fibrocartilage complex (TFCC) using compressed sensing-sensitivity encoding (CS-SENSE). Methods: Three-dimensional fast field echo T2-weighted images were obtained from 13 healthy volunteers using the original, high spatial resolution sequence with CS-SENSE [HR (CS-SENSE)] and without CS-SENSE (HR) and super-high spatial resolution sequence with CS-SENSE [S-HR (CS-SENSE)] and without CS-SENSE (S-HR). For qualitative analysis, the number of patients affected by motion artifacts in each sequence was counted, and the visualization of the TFCC anatomic structures and overall image quality were categorized. For the quantitative analysis, relative signal intensity (SI) and relative contrast of the lunate bone marrow, lunate cartilage, and disk proper in the wrist joint were all calculated. Results: The HR (CS-SENSE) sequence showed better visualization scores than the original sequence in the triangular ligament at the ulnar styloid tip, dorsal radioulnar ligament, and ulnotriquetral ligament. Similarly, the S-HR (CS-SENSE) sequence showed better visualization scores than the original sequence in the triangular ligament at the ulnar styloid tip and dorsal radioulnar ligament. Overall image quality scores were not signifi-cantly different, and motion artifacts in the HR and S-HR sequences were observed in 3 of the 13 patients. In contrast, the original sequence showed higher values than those in the HR (CS-SENSE) and S-HR (CS-SENSE) sequences in relative SI of the bone marrow and relative contrast of the cartilage-bone marrow and cartilage-disk proper. Conclusions: Out of the three sequences, the HR (CS-SENSE) sequence provided the highest visualization score and diagnostically sufficient image quality score, although relative SI and relative contrast were low. The HR (CS-SENSE) sequence may be clinically useful for imaging TFCCs.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] The utility of high-resolution magnetic resonance imaging in the evaluation of the triangular fibrocartilage complex of the wrist
    Potter, HG
    AsnisErnberg, L
    Weiland, AJ
    Hotchkiss, RN
    Peterson, MGE
    McCormack, RR
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (11): : 1675 - 1684
  • [2] Magnetic resonance imaging of triangular fibrocartilage complex lesions
    Potter, HG
    Weiland, AJ
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (02): : 363 - 364
  • [3] MAGNETIC-RESONANCE-IMAGING OF THE TRIANGULAR FIBROCARTILAGE COMPLEX
    SKAHEN, JR
    PALMER, AK
    LEVINSOHN, EM
    BUCKINGHAM, SC
    SZEVERENYI, NM
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (04): : 552 - 557
  • [4] High resolution magnetic resonance imaging using compressed sensing-Sensitivity encoding for patients with suspected neurovascular compression syndrome: Comparison with conventional sense parallel technique
    Cho, S. J.
    Choi, Y. J.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2019, 405
  • [5] High-Resolution 3T MR Imaging of the Triangular Fibrocartilage Complex
    von Borstel, Donald
    Wang, Michael
    Small, Kirstin
    Nozaki, Taiki
    Yoshioka, Hiroshi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (01) : 3 - 15
  • [6] MAGNETIC-RESONANCE-IMAGING OF TRIANGULAR FIBROCARTILAGE COMPLEX TEARS
    OMARINI, LPA
    GARCIA, J
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1995, 125 (17) : 854 - 859
  • [7] Magnetic resonance imaging of triangular fibrocartilage complex lesions - Reply
    Blazar, PE
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (02): : 364 - 364
  • [8] High-Resolution Magnetic Resonance Imaging of Triangular Fibrocartilage Complex Lesions in Acute Wrist Trauma: Image Quality at Different Field Strengths
    Stehling, Christoph
    Bachmann, Rainald
    Langer, Martin
    Nassenstein, Isabelle
    Heindel, Walter
    Vieth, Volker
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (04) : 579 - 583
  • [9] Dynamic changes in the shape of the triangular fibrocartilage complex during rotation demonstrated with high resolution magnetic resonance imaging
    Nakamura, T
    Yabe, Y
    Horiuchi, Y
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1999, 24B (03): : 338 - 341
  • [10] High-Resolution Magnetic Resonance Imaging Using Compressed Sensing for Intracranial and Extracranial Arteries: Comparison with Conventional Parallel Imaging
    Suh, Chong Hyun
    Jung, Seung Chai
    Lee, Ho Beom
    Cho, Se Jin
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (03) : 487 - 497