Screening outcome for consecutive examinations with digital breast tomosynthesis versus standard digital mammography in a population-based screening program

被引:22
|
作者
Hovda, Tone [1 ]
Brandal, Siri H. B. [2 ]
Sebuadegard, Sofie [3 ]
Holen, Asne S. [3 ]
Bjorndal, Hilde [1 ]
Skaane, Per [2 ]
Hofvind, Solveig [3 ,4 ]
机构
[1] Vestre Viken Hosp, Dept Radiol, Drammen, Norway
[2] Oslo Univ Hosp, Div Radiol & Nucl Med, Oslo, Norway
[3] Canc Registry Norway, PO 5313, N-0304 Oslo, Norway
[4] Oslo Metropolitan Univ, Fac Hlth Sci, Oslo, Norway
关键词
Screening; Breast neoplasm; Digital breast tomosynthesis; Mammography; Digital mammography; RATES; STORM;
D O I
10.1007/s00330-019-06264-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To retrospectively investigate early performance measures of digital breast tomosynthesis (DBT) versus standard digital mammography (DM) for consecutive screening rounds. Methods We included information about 35,736 women screened in BreastScreen Norway, 2008-2016, with at least two consecutive screening examinations. The pair of two consecutive screening examinations was the unit of analysis, and results from the subsequent examination were the measure of interest. Screening technique changed during the study period, resulting in four study groups: DM after DM, DBT after DM, DM after DBT, and DBT after DBT. We compared selected early performance measures between the study groups. Results Recall for DM after DM was 3.6% and lower for all other study groups (p < 0.001). The rate of screen-detected breast cancer was 4.6/1000 for DM after DM; for DBT after DM and DBT after DBT, it was 9.9/1000 and 8.3/1000, respectively (p < 0.001 relative to DM after DM), and for DM after DBT 4.3/1000. The rate of tubular carcinoma was higher for DBT after DBT or after DM compared with DM after DM (p < 0.01). The rate of histologic grade 1 tumors was higher for DBT after DM compared with DM after DM (p < 0.001). We did not observe any statistical difference in the interval cancer rates. Conclusions Lower recall and higher cancer detection rates for screening with DBT were sustainable over two consecutive screening rounds. Positive predictive values were higher for DBT than DM. There were no differences in the interval cancer rates between the study groups. Key Points There is limited knowledge about early performance measures for screening with digital breast tomosynthesis beyond one screening round. A decline in recall rate and an incline in the rate of screen-detected breast cancer were observed for women screened with DBT compared with DM, irrespective of prior screening technique. The interval breast cancer rate did not differ statistically for women screened with DBT versus DM. Tumor characteristics tended to be prognostic favorable for DBT compared with DM with no differences in rates of more advanced cancers. The clinical significance of increased cancer detection and the potential for future mortality reduction remain unknown.
引用
收藏
页码:6991 / 6999
页数:9
相关论文
共 50 条
  • [1] Screening outcome for consecutive examinations with digital breast tomosynthesis versus standard digital mammography in a population-based screening program
    Tone Hovda
    Siri H. B. Brandal
    Sofie Sebuødegård
    Åsne S. Holen
    Hilde Bjørndal
    Per Skaane
    Solveig Hofvind
    [J]. European Radiology, 2019, 29 : 6991 - 6999
  • [2] Digital Breast Tomosynthesis and Synthetic 2D Mammography versus Digital Mammography: Evaluation in a Population-based Screening Program
    Hofvind, Solveig
    Hovda, Tone
    Holen, Asne S.
    Lee, Christoph I.
    Albertsen, Judy
    Bjorndal, Hilde
    Brandal, Siri H. B.
    Gullien, Randi
    Lomo, Jon
    Park, Daehoon
    Romundstad, Linda
    Suhrke, Pal
    Vigeland, Einar
    Skaane, Per
    [J]. RADIOLOGY, 2018, 287 (03) : 787 - 794
  • [3] Comparison of Digital Mammography Alone and Digital Mammography Plus Tomosynthesis in a Population-based Screening Program
    Skaane, Per
    Bandos, Andriy I.
    Gullien, Randi
    Eben, Ellen B.
    Ekseth, Ulrika
    Haakenaasen, Unni
    Izadi, Mina
    Jebsen, Ingvild N.
    Jahr, Gunnar
    Krager, Mona
    Niklason, Loren T.
    Hofvind, Solveig
    Gur, David
    [J]. RADIOLOGY, 2013, 267 (01) : 47 - 56
  • [4] Digital Mammography versus Breast Tomosynthesis: Impact of Breast Density on Diagnostic Performance in Population-based Screening
    Osteras, Bjorn Helge
    Martinsen, Anne Catrine T.
    Gullien, Randi
    Skaane, Per
    [J]. RADIOLOGY, 2019, 293 (01) : 60 - 68
  • [5] Digital Mammography versus Digital Mammography Plus Tomosynthesis in Breast Cancer Screening: The Oslo Tomosynthesis Screening Trial
    Skaane, Per
    Bandos, Andriy L.
    Niklason, Loren T.
    Sebuodegard, Sofie
    Osteras, Bjorn H.
    Gullien, Randi
    Gur, David
    Hofvind, Solveig
    [J]. RADIOLOGY, 2019, 291 (01) : 22 - 29
  • [6] Implementation of Synthesized Two-dimensional Mammography in a Population-based Digital Breast Tomosynthesis Screening Program
    Zuckerman, Samantha P.
    Conant, Emily F.
    Keller, Brad M.
    Maidment, Andrew D. A.
    Barufaldi, Bruno
    Weinstein, Susan P.
    Synnestvedt, Marie
    McDonald, Elizabeth S.
    [J]. RADIOLOGY, 2016, 281 (03) : 730 - 736
  • [7] Screening outcomes of digital Breast tomosynthesis versus digital mammography in an underserved population with multiple disparities
    McLarty, Jerry W.
    Lance, Jennifer
    Collins, Towanno
    Grubbs, Sharon
    Massey, Stacey
    Luraguiz, Nelson
    [J]. CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2017, 26 (02)
  • [8] Microcalcifications Detected at Screening Mammography: Synthetic Mammography and Digital Breast Tomosynthesis versus Digital Mammography
    Lai, Yi-Chen
    Ray, Kimberly M.
    Lee, Amie Y.
    Hayward, Jessica H.
    Freimanis, Rita I.
    Lobach, Iryna V.
    Joe, Bonnie N.
    [J]. RADIOLOGY, 2018, 289 (03) : 630 - 638
  • [9] Outcomes by Race in Breast Cancer Screening With Digital Breast Tomosynthesis Versus Digital Mammography
    Alsheik, Nila
    Blount, Linda
    Qiong, Qiu
    Talley, Melinda
    Pohlman, Scott
    Troeger, Kathleen
    Abbey, Genevieve
    Mango, Victoria L.
    Pollack, Erica
    Chong, Alice
    Donadio, Greg
    Behling, Michael
    Mortimer, Kathleen
    Conant, Emily
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2021, 18 (07) : 906 - 918
  • [10] Breast Cancer Screening With Tomosynthesis and Digital Mammography
    Seidenwurm, David
    Rosenberg, Robert
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (16): : 1695 - 1695