Evaluation of the effectiveness of electrical muscle stimulation on human calf muscles via frequency difference electrical impedance tomography

被引:25
|
作者
Sun, Bo [1 ]
Baidillah, Marlin Ramadhan [1 ]
Darma, Panji Nursetia [1 ]
Shirai, Tomoyuki [2 ]
Narita, Kosei [2 ]
Takei, Masahiro [1 ]
机构
[1] Chiba Univ, Grad Sch Sci & Engn, Dept Mech Engn, Chiba, Japan
[2] MTG Co Ltd, Nagoya, Aichi, Japan
关键词
electrical muscle stimulation; frequency difference electrical impedance tomography; response muscle areas; muscle extracellular volumes; HUMAN SKELETAL-MUSCLE; EXERCISE; RECOVERY; MRI; CONTRACTION; RECRUITMENT; ACTIVATION; MASSAGE; HEALTHY; SENSOR;
D O I
10.1088/1361-6579/abe9ff
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objectives. The human skeletal muscle responds immediately under electrical muscle stimulation (EMS), and there is an immediate physiological response in human skeletal muscle. Non-invasive quantitative analysis is at the heart of our understanding of the physiological significance of human muscle changes under EMS. Response muscle areas of human calf muscles under EMS have been detected by frequency difference electrical impedance tomography (fd-EIT). Approach. The experimental protocol consists of four parts: pre-training (pre), training (tra), post-training (post), and relaxation (relax) parts. The relaxation part has three relaxation conditions, which are massage relaxation (MR), cold pack relaxation (CR), and hot pack relaxation (HR). Main results. From the experimental results, conductivity distribution images sigma(p) (p means protocol = pre, tra, post, or relax) are clearly reconstructed by fd-EIT as response muscle areas, which are called the M-1 response area (composed of gastrocnemius muscle) and the M-2 response area (composed of the tibialis anterior muscle, extensor digitorum longus muscle, and peroneus longus muscle). A paired samples t-test was conducted to elucidate the statistical significance of spatial-mean conductivities sigma(p)(M1) and sigma(p)(M2) in M-1 and M-2 with reference to the conventional extracellular water ratio beta(p) by bioelectrical impedance analysis. Significance. From the t-test results, sigma(p)(M1) and sigma(p)(M2) have good correlation with beta(p). In the post-training part, sigma(post) and beta(post) were significantly higher than in the pre-training part (n = 24, p < 0.001). The relax-pre difference ratios of spatial-mean conductivity Delta sigma(relax-pre) and the relax-pre difference ratios of extracellular water ratio Delta beta(relax-pre) in both MR and CR were lower; on the contrary, the Delta sigma(relax-pre) and Delta beta(relax-pre) in HR were significantly higher than those in post-pre difference ratios of spatial-mean conductivity Delta sigma(post-pre) (n = 8, p < 0.05). The reason for the changes in sigma(p)(M1) and sigma(p)(M2) are caused by the changes in muscle extracellular volumes. In conclusion, fd-EIT satisfactorily evaluates the effectiveness of human calf muscles under EMS.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Electrical Characteristics of Calf Muscles Under Neuromuscular Electrical Stimulation*
    Sun, Bo
    Darma, Panji Nursetia
    Zhang, Quan-Cheng
    Yao, Jia-Feng
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2023, 50 (06) : 1443 - 1453
  • [2] Electrical impedance tomography in the evaluation of effectiveness of chest physiotherapy
    Folino, Anna
    Beux, Sheila
    Barrocu, Laura
    Esposito, Irene
    Rizza, Elvira
    Goia, Manuela
    Appendini, Lorenzo
    Bignamini, Elisabetta
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [3] Local Muscle Quality Imaging in Human Calf by Phase Angle Electrical Impedance Tomography (ΦEIT)
    Darma, Panji Nursetia
    Sun, Bo
    Sejati, Prima Asmara
    Takei, Masahiro
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 11
  • [4] Visualization of fluid shifts in the human calf using electrical impedance tomography
    Scratcherd, T
    Otun, H
    Ahmed, B
    Greenwell, JR
    Kotre, J
    Gillespie, JI
    JOURNAL OF PHYSIOLOGY-LONDON, 1996, 497P : P69 - P69
  • [5] Combining frequency-difference and ultrasound modulated electrical impedance tomography
    Harrach, Bastian
    Lee, Eunjung
    Ullrich, Marcel
    INVERSE PROBLEMS, 2015, 31 (09)
  • [6] Multiple Weighted Frequency-difference Method for Electrical Impedance Tomography
    Hu, Qingwei
    Xu, Yanbin
    Liu, Ziqi
    Li, Changbin
    Dong, Feng
    2021 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2021), 2021,
  • [7] Multi-frequency Electrical Impedance Tomography and Magnetic Resonance Electrical Impedance Tomography
    Seo, Jin Keun
    Woo, Eung Je
    MATHEMATICAL MODELING IN BIOMEDICAL IMAGING I: ELECTRICAL AND ULTRASOUND TOMOGRAPHIES, ANOMALY DETECTION, AND BRAIN IMAGING, 2009, 1983 : 1 - 71
  • [8] Relationship between fat thickness and current density magnitude in calf muscles compartments under electrical muscle stimulation (EMS) by coupling of electromagnetic simulation and electrical impedance tomography (ES-EIT)
    Sun, Bo
    Darma, Panji Nursetia
    Ikeda, Kaname
    Shirai, Tomoyuki
    Narita, Kosei
    Takei, Masahiro
    JOURNAL OF VISUALIZATION, 2023, 26 (06) : 1375 - 1388
  • [9] Relationship between fat thickness and current density magnitude in calf muscles compartments under electrical muscle stimulation (EMS) by coupling of electromagnetic simulation and electrical impedance tomography (ES-EIT)
    Bo Sun
    Panji Nursetia Darma
    Kaname Ikeda
    Tomoyuki Shirai
    Kosei Narita
    Masahiro Takei
    Journal of Visualization, 2023, 26 : 1375 - 1388
  • [10] Multi frequency electrical impedance tomography
    Brandstätter, B
    Scharfetter, H
    Magele, C
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2001, 20 (03) : 828 - 847