Analysis of the horizontal corneal diameter, central corneal thickness, and axial length in premature infants

被引:8
|
作者
Ozdemir, Ozdemir [1 ]
Tunay, Zuhal Ozen [1 ]
Petricli, Ikbal Seza [2 ]
Acar, Damla Erginturk [1 ]
Acar, Ugur [3 ]
Erol, Muhammet Kazim [4 ]
机构
[1] Zekai Tahir Burak Womens Hlth Educ & Res Hosp, Dept Ophthalmol, Ankara, Turkey
[2] Etlik Zubeyde Hanim Matern & Womens Hlth Res Hosp, Dept Ophthalmol, Ankara, Turkey
[3] Hacettepe Univ, Kastamonu Fac Med, Dept Ophthalmol, Ankara, Turkey
[4] Antalya Educ & Res Hosp, Dept Ophthalmol, Antalya, Turkey
关键词
Cornea/anatomy and histology; Retinopathy of prematurity; Infant; premature; Birth weight; Gestational age; SEVERE RETINOPATHY; REFRACTIVE ERROR; BIOMETRY; GROWTH;
D O I
10.5935/0004-2749.20140058
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the horizontal corneal diameter, central corneal thickness, and axial length in premature infants. Methods: Infants with a birth weight of less than 2,500 g or with a gestation period of less than 36 weeks were included in the study. Infants with retinopathy of prematurity (ROP) were allocated to Group 1 (n= 138), while those without ROP were allocated to Group 2 (n= 236). All infants underwent a complete ophthalmologic examination, including corneal diameter measurements, pachymetry, biometry, and fundoscopy. Between-group comparisons of horizontal corneal diameter, central corneal thickness, and axial lengths were performed. Independent sample t-tests were used for statistical analysis. Results: Data was obtained from 374 eyes of 187 infants (102 female, 85 male). The mean gestational age at birth was 30.7 +/- 2.7 weeks (range 25-36 weeks), the mean birth weight was 1,514 +/- 533.3 g (range 750-1,970 g), and the mean postmenstrual age at examination was 40.0 +/- 4.8 weeks. The mean gestational age and the mean birth weight of Group 1 were statistically lower than Group 2 (p < 0.05). There were no significant differences in horizontal corneal diameter, central corneal thickness, and axial length between the two groups (p > 0.05). Conclusions: The presence of ROP in premature infants does not alter the horizontal corneal diameter, central corneal thickness, or axial length.
引用
收藏
页码:225 / 227
页数:3
相关论文
共 50 条
  • [1] Central corneal thickness changes and horizontal corneal diameter in premature infants A prospective analysis
    Choo, May May
    Yeong, Choo Mee
    Grigg, John R.
    Khaliddin, Nurliza
    Kadir, Azida Juana
    Barnes, Elizabeth H.
    Kamalden, Tengku Ain
    Watson, Stephanie L.
    [J]. MEDICINE, 2018, 97 (48)
  • [2] Central corneal thickness and corneal diameter in premature infants
    Kirwan, C
    O'Keefe, M
    Fitzsimon, S
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2005, 83 (06): : 751 - 753
  • [3] Effect of intraocular pressure control on central corneal thickness, horizontal corneal diameter, and axial length in primary congenital glaucoma
    Cronemberger, Sebastiao
    Calixto, Nassim
    Avellar Milhomens, Thiago Gutemberg
    Gama, Priscila Ottoni
    Milhomens, Eduardo Gutemberg
    Rolim, Hevila
    Mendonca, Swethlana Calheiros
    [J]. JOURNAL OF AAPOS, 2014, 18 (05): : 433 - 436
  • [4] CORNEAL DIAMETER, AXIAL LENGTH, AND INTRAOCULAR-PRESSURE IN PREMATURE-INFANTS
    TUCKER, SM
    ENZENAUER, RW
    LEVIN, AV
    MORIN, JD
    HELLMANN, J
    [J]. OPHTHALMOLOGY, 1992, 99 (08) : 1296 - 1300
  • [5] Central corneal thickness measurements in premature infants
    Gunay, Murat
    Celik, Gokhan
    Gunay, Betul Onal
    Dogru, Mahmut
    Gursoy, Tugba
    Ovali, Husnu Fahri
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (03) : 496 - 500
  • [6] Central corneal thickness measurements in premature infants
    Murat Gunay
    Gokhan Celik
    Betul Onal Gunay
    Mahmut Dogru
    Tugba Gursoy
    Husnu Fahri Ovali
    [J]. International Journal of Ophthalmology, 2014, (03) : 496 - 500
  • [7] Central corneal thickness and intraocular pressure in premature infants
    Mehmet Ali Sekeroglu
    Emre Hekimoglu
    İkbal Seza Petricli
    Jale Karakaya
    Beyza Ozcan
    Husniye Yucel
    Aysen Sumru Kavurt
    Ahmet Yagmur Bas
    [J]. International Ophthalmology, 2015, 35 : 847 - 851
  • [8] Central corneal thickness and intraocular pressure in premature infants
    Sekeroglu, Mehmet Ali
    Hekimoglu, Emre
    Petricli, Ikbal Seza
    Karakaya, Jale
    Ozcan, Beyza
    Yucel, Husniye
    Kavurt, Aysen Sumru
    Bas, Ahmet Yagmur
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2015, 35 (06) : 847 - 851
  • [9] Axial length, anterior chamber depth, lens thickness and horizontal corneal diameter in normal children
    Costa, AMC
    Calixto, N
    Milhomens, EG
    Cronemberger, S
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [10] Lamina cribrosa thickness is not correlated with central corneal thickness or axial length in healthy eyesCentral corneal thickness, axial length, and lamina cribrosa thickness
    Eun Ji Lee
    Tae-Woo Kim
    Robert N. Weinreb
    Min Hee Suh
    Hyunjoong Kim