Impact of abutment material on peri-implant soft tissue color. An in vitro study

被引:26
|
作者
Sala, Leticia [1 ,2 ]
Bascones-Martinez, Antonio [1 ,2 ]
Carrillo-de-Albornoz, Ana [1 ,2 ]
机构
[1] Univ Complutense Madrid, Sch Dent, Dept Periodontol, Madrid, Spain
[2] Univ Complutense Madrid, Fac Odontol, Dept Estomatol 3, Plaza Ramon & Cajal S-N, Madrid 28040, Spain
关键词
Gingival color; Spectrophotometer; Abutment; Peri-implant; Soft tissue; Gingiva; ZIRCONIA ABUTMENTS; TITANIUM ABUTMENTS; SUPPORTED RESTORATIONS; OPTICAL PHENOMENON; MUCOSA; PERMEABILITY; TRANSLUCENCY; MULTICENTER; DENTISTRY; OUTCOMES;
D O I
10.1007/s00784-016-2015-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The objectives of the present study is to determine the differences in peri-implant soft tissue color with the utilization of titanium, titanium gold-plated, white zirconia, Vita Classical (VC) A4-shaded zirconia, and fluorescent white zirconia abutments and to establish the influence of gingival thickness on the resulting color. Four implants were contralaterally inserted in 19 fresh pig mandibles, and the color of the peri-implant mucosa with the different abutments was spectrophotometrically measured at 1-, 2-, and 3-mm height from the margin. At 1-mm height, titanium significantly differed from all zirconia abutments in lightness (L*), chroma along red axis (a*), and chroma along yellow-blue axis (b*) parameters. At 2 mm, all zirconia abutments differed from titanium in b* but only fluorescent zirconia in a*. At 3 mm, titanium differed from VC A4-shaded and fluorescent zirconia abutments in b*. At soft tissue thicknesses < 1 and 1-2 mm, titanium differed from fluorescent zirconia in a* and b* and from VC A4-shaded zirconia in b*; at thickness > 2 mm, no differences were found among abutments. All abutments differed from natural teeth in a* and b* at all heights and thicknesses except for fluorescent zirconia at thickness > 2 mm. The Euclidean distance (Delta I center dot) differed between titanium abutments and gold, VC A4, and fluorescent zirconia at < 1- and 1-2-mm thicknesses. The natural gingival color was not reproduced with any abutment at gingival thicknesses < 2 mm. The worst color match was with titanium abutments and the best with fluorescent zirconia, followed by VC A4-shaded zirconia. At gingival thicknesses > 2 mm, no differences were detected among abutments. This study demonstrates that the type of abutment and the gingival thickness affect the resulting peri-implant gingival color.
引用
下载
收藏
页码:2221 / 2233
页数:13
相关论文
共 50 条
  • [1] Impact of abutment material on peri-implant soft tissue color. An in vitro study
    Leticia Sala
    Antonio Bascones-Martínez
    Ana Carrillo-de-Albornoz
    Clinical Oral Investigations, 2017, 21 : 2221 - 2233
  • [2] Abutment material and peri-implant soft tissue
    Reena Wadia
    British Dental Journal, 2020, 228 (2) : 82 - 82
  • [3] Abutment Material Effect on Peri-implant Soft Tissue Color and Perceived Esthetics
    Kim, Aram
    Campbell, Stephen D.
    Viana, Marlos A. G.
    Knoernschild, Kent L.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (08): : 634 - 640
  • [4] Evaluation of color stabilization of peri-implant mucosa in different restorative material, abutment and tissue thickness combinations: an in vitro study
    Kuzu, T. E.
    Ozturk, K.
    Unlu, D. Gunes
    JOURNAL OF OSSEOINTEGRATION, 2022, 14 (04) : 241 - 245
  • [5] Revisiting peri-implant soft tissue - histopathological study of the peri-implant soft tissue
    Silva, Eduarda
    Felix, Sergio
    Rodriguez-Archilla, Alberto
    Oliveira, Pedro
    dos Santos, Jose Martins
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2014, 7 (02): : 611 - 618
  • [6] The Effects of Abutment Materials on Peri-Implant Soft Tissue Integration: A Study in Minipigs
    Dethier, Frederic
    Bacevic, Miljana
    Lecloux, Geoffrey
    Seidel, Laurence
    Rompen, Eric
    Lambert, France
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (07): : 585 - 592
  • [7] A Systematic Review and Meta-Analysis of the Influence of Abutment Material on Peri-implant Soft Tissue Color Measured Using Spectrophotometry
    Pitta, Joao
    Zarauz, Cristina
    Pjetursson, Bjarni
    Sailer, Irena
    Liu, Xinran
    Pradies, Guillermo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (01) : 39 - 47
  • [8] Spectrophotometric and visual evaluation of peri-implant soft tissue color
    Benic, Goran I.
    Scherrer, Daniela
    Sancho-Puchades, Manuel
    Thoma, Daniel S.
    Hammerle, Christoph H. F.
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (02) : 192 - 200
  • [9] Immunohistochemical assessment of the peri-implant soft tissue around different abutment materials: A human study
    Serichetaphongse, Pravej
    Chengprapakorn, Wareeratn
    Thongmeearkom, Sirikarn
    Pimkhaokham, Atiphan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (05) : 638 - 646
  • [10] Effects of a New Implant Abutment Design on Peri-Implant Soft Tissues
    Chien, Hua-Hong
    Schroering, Robert L.
    Prasad, Hari S.
    Tatakis, Dimitris N.
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (05) : 581 - 588