Calibration and data restoration of light field modulated imaging spectrometer

被引:1
|
作者
Su, Li-Juan [1 ]
Yan, Qiang-Qiang [1 ,2 ]
Yuan, Yan [1 ]
Wang, Shi-Feng [1 ]
Liu, Yu-Jian [1 ]
机构
[1] Beihang Univ, Minist Educ, Key Lab Precis Optomechatron Technol, Beijing 100191, Peoples R China
[2] Chinese Acad Sci, Xian Inst Opt & Precis Mech, Key Lab Spectral Imaging Technol, Xian 710119, Shaanxi, Peoples R China
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
light field modulated imaging spectrometer; linear-variable filter; spectral calibration; spectral reconstruction; TOTAL LEAST-SQUARES; SPECTROSCOPY; RESOLUTION;
D O I
10.1088/1674-1056/27/8/080702
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A light field modulated imaging spectrometer (LFMIS) can acquire the spatial-spectral datacube of targets of interest or a scene in a single shot. The spectral information of a point target is imaged on the pixels covered by a microlens. The pixels receive spectral information from different spectral filters to the diffraction and misalignments of the optical components. In this paper, we present a linear spectral multiplexing model of the acquired target spectrum. A calibration method is proposed for calibrating the center wavelengths and bandwidths of channels of an LFMIS system based on the liner-variable filter (LVF) and for determining the spectral multiplexing matrix. In order to improve the accuracy of the restored spectral data, we introduce a reconstruction algorithm based on the total least square (TLS) approach. Simulation and experimental results confirm the performance of the spectrum reconstruction algorithm and validate the feasibility of the proposed calibrating scheme.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Calibration and data restoration of light field modulated imaging spectrometer
    苏丽娟
    严强强
    袁艳
    王世丰
    刘宇健
    [J]. Chinese Physics B, 2018, (08) : 183 - 190
  • [2] Laboratory Calibration of a Field Imaging Spectrometer System
    Zhang, Lifu
    Huang, Changping
    Wu, Taixia
    Zhang, Feizhou
    Tong, Qingxi
    [J]. SENSORS, 2011, 11 (03) : 2408 - 2425
  • [3] Radiometric calibration of tempospatially modulated polarization interference imaging spectrometer
    Gao, Peng
    Ai, Jingjing
    Zhang, Chunmin
    [J]. APPLIED OPTICS, 2016, 55 (35) : 10016 - 10024
  • [4] Radiometric restoration of airborne imaging spectrometer data
    Guo, XF
    Wang, RS
    Cheng, JC
    Wang, QH
    [J]. HYPERSPECTRAL REMOTE SENSING AND APPLICATIONS, 1998, 3502 : 65 - 73
  • [5] A snapshot light field imaging spectrometer
    Su, Lijuan
    Zhou, Zhiliang
    Yuan, Yan
    Hu, Liang
    Zhang, Siyuan
    [J]. OPTIK, 2015, 126 (9-10): : 877 - 881
  • [6] Outfield calibration analysis of spatially modulated imaging fourier transform spectrometer
    Gao J.
    Ji Z.
    Cui Y.
    Wang Z.
    Shi D.
    [J]. Guangxue Xuebao/Acta Optica Sinica, 2010, 30 (05): : 1321 - 1326
  • [7] Calibration of the KMOS multi-field imaging spectrometer
    Ramsay, S. K.
    Rolt, S.
    Sharples, R. M.
    Davies, R.
    [J]. THE 2007 ESO INSTRUMENT CALIBRATION WORKSHOP, 2008, : 319 - +
  • [8] A Radiometric Calibration Model for the Field Imaging Spectrometer System
    Huang, Changping
    Zhang, Lifu
    Fang, Junyong
    Tong, Qingxi
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (04): : 2465 - 2475
  • [9] Data Reconstructed of Ultraviolet Spatially Modulated Imaging Spectrometer
    Yuan Xiaochun
    Yu Chunchao
    Yang Zhixiong
    Yan Min
    Zeng Yi
    [J]. HYPERSPECTRAL REMOTE SENSING APPLICATIONS AND ENVIRONMENTAL MONITORING AND SAFETY TESTING TECHNOLOGY, 2016, 10156
  • [10] Portable Remote Imaging Spectrometer (PRISM): laboratory and field calibration
    Mouroulis, Pantazis
    Van Gorp, Byron
    Green, Robert O.
    Eastwood, Michael
    Boardman, Joseph
    Richardson, Brandon S.
    Rodriguez, Jose I.
    Urquiza, Eugenio
    Franklin, Brian D.
    Gao, Bo-Cai
    [J]. IMAGING SPECTROMETRY XVII, 2012, 8515