An evaluation of the effectiveness of the patellar tendon bar in the trans-tibial patellar-tendon-bearing prosthesis socket

被引:0
|
作者
Kim, WD
Lim, D
Hong, KS
机构
[1] Nanyang Technol Univ, Sch Mech & Prod Engn, Singapore 639798, Singapore
[2] Tan Tock Seng Hosp, Artificial Limb Ctr, Singapore, Singapore
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of this study is to determine the relationship between varying depths of the patellar tendon bar in trans-tibial prosthesis sockets and the pressures exerted by other regions within the socket, such as the tibial crest, medial and lateral tibial condyles, lateral femoral condyle and the distal tibial end. Five (5) patients selected from a population of trans-tibial amputees in Singapore. Patellar-tendon-bearing (PTB) sockets were made for them. Polypropylene spacers 2mm thick were used to simulate the increasing depths of the patellar tendon bar. P-Scan pressure transducers were inserted into the sockets to measure the pressures exerted by the socket and the data collected were analysed statistically to see if there was a relationship between varying PTB depths and pressures exerted from selected parts of the socket.
引用
收藏
页码:23 / 35
页数:13
相关论文
共 50 条
  • [1] Patellar tendon morphology in trans-tibial amputees utilizing a prosthesis with a patellar-tendon-bearing feature
    Ho, Kai-Yu
    Harty, Michelle
    Kellogg, Jessica
    Teter, Kelly
    Lee, Szu-Ping
    Chang, Yu-Jen
    Bashford, Gregory
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [2] Patellar tendon morphology in trans-tibial amputees utilizing a prosthesis with a patellar-tendon-bearing feature
    Kai-Yu Ho
    Michelle Harty
    Jessica Kellogg
    Kelly Teter
    Szu-Ping Lee
    Yu-Jen Chang
    Gregory Bashford
    Scientific Reports, 9
  • [3] Suspension effect and dynamic evaluation of the total surface bearing (TSB) trans-tibial prosthesis: a comparison with the patellar tendon bearing (PTB) trans-tibial prosthesis
    Narita, H
    Yokogushi, K
    Shii, S
    Kakizawa, M
    Nosaka, T
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1997, 21 (03) : 175 - 178
  • [4] A new alignment jig for quantification and prescription of three-dimensional alignment for the patellar-tendon-bearing trans-tibial prosthesis
    Sin, SW
    Chow, DHK
    Cheng, JCY
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1999, 23 (03) : 225 - 230
  • [5] PATELLAR-TENDON-BEARING ORTHOSIS
    TITUS, BR
    ORTHOTICS AND PROSTHETICS, 1975, 29 (01): : 35 - 40
  • [6] RADIOLOGIC TECHNIQUE TO EVALUATE PATELLAR-TENDON-BEARING PROSTHESIS
    SEEBER, JJ
    MAGILNER, A
    REYES, T
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1972, 53 (02): : 65 - &
  • [7] FRACTURES OF TIBIAL SHAFT TREATED IN A PATELLAR-TENDON-BEARING CAST
    MOLLAN, RAB
    BRADLEY, B
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1978, 10 (02): : 124 - 127
  • [8] Static and dynamic pressure profiles of a patellar-tendon-bearing (PTB) socket
    Goh, JCH
    Lee, PVS
    Chong, SY
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2003, 217 (H2) : 121 - 126
  • [9] EVALUATION OF 3 CASTING TECHNIQUES FOR PATELLAR-TENDON-BEARING PROSTHESES
    QUIGLEY, MJ
    WILSON, AB
    ORTHOTICS AND PROSTHETICS, 1975, 29 (02): : 21 - 32
  • [10] Conventional patellar-tendon-bearing (PTB) socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee.
    Convery, P
    Buis, AWP
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1998, 22 (03) : 193 - 198