Cine CT for attenuation correction in cardiac PET/CT

被引:78
|
作者
Alessio, Adam M.
Kohmyer, Steve
Branch, Kelley
Chen, Grace
Caldwell, James
Kinahan, Paul
机构
[1] Univ Washington, Old Fisheries Ctr, Dept Radiol, Seattle, WA 98195 USA
[2] Univ Washington, Div Cardiol, Seattle, WA 98195 USA
[3] GE Healthcare, Waukesha, WA USA
关键词
PET/CT; 4DCT; attenuation correction; cardiac imaging; respiratory motion;
D O I
10.2967/jnumed.106.035717
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In dual-modality PET/CT systems, the CT scan provides the attenuation map for PET attenuation correction. The current clinical practice of obtaining a single helical CT scan provides only a snapshot of the respiratory cycle, whereas PET occurs over multiple respiratory cycles. Misalignment of the attenuation map and emission image because of respiratory motion causes errors in the attenuation correction factors and artifacts in the attenuation-corrected PET image. To rectify this problem, we evaluated the use of cine CT, which acquires multiple low-dose CT images during a respiratory cycle. We evaluated the average and the intensity-maximum image of cine CT for cardiac PET attenuation correction. Methods: Cine CT data and cardiac PET data were acquired from a cardiac phantom and from multiple patient studies. The conventional helical CT, cine CT, and PET data of an axially translating phantom were evaluated with and without respiratory motion. For the patient studies, we acquired 2 cine CT studies for each PET acquisition in a rest-stress N-13-ammonia protocol. Three readers visually evaluated the alignment of 74 attenuation image sets versus the corresponding emission image and determined whether the alignment provided acceptable or unacceptable attenuation-corrected PET images. Results: In the phantom study, the attenuation correction from helical CT caused a major artifactual defect in the lateral wall on the PET image. The attenuation correction from the average and from the intensity-maximum cine CT images reduced the defect by 20% and 60%, respectively. In the patient studies, 77% of the cases using the average of the cine CT images had acceptable alignment and 88% of the cases using the intensity maximum of the cine CT images had acceptable alignment. Conclusion: Cine CT offers an alternative to helical CT for compensating for respiratory motion in the attenuation correction of cardiac PET studies. Phantom studies suggest that the average and the intensity maximum of the cine CT images can reduce potential respiration-induced misalignment errors in attenuation correction. Patient studies reveal that cine CT provides acceptable alignment in most cases and suggest that the intensity-maximum cine image offers a more robust alternative to the average cine image.
引用
收藏
页码:794 / 801
页数:8
相关论文
共 50 条
  • [1] Attenuation correction of cardiac PET with endexpiratory CT and average CT
    Sander, K.
    Pan, T.
    Roby, A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S699 - S699
  • [2] Interpolated average CT for cardiac PET/CT attenuation correction
    Greta S. P. Mok
    Cobie Y. T. Ho
    Bang-Hung Yang
    Tung-Hsin Wu
    [J]. Journal of Nuclear Cardiology, 2016, 23 : 1072 - 1079
  • [3] Interpolated average CT for cardiac PET/CT attenuation correction
    Mok, Greta S. P.
    Ho, Cobie Y. T.
    Yang, Bang-Hung
    Wu, Tung-Hsin
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (05) : 1072 - 1079
  • [4] Automatic Registration of Cardiac PET/CT for Attenuation Correction
    Bond, Sarah
    Kadir, Timor
    Hamill, James
    Casey, Michael
    Platsch, Guenther
    Burckhardt, Darrell
    Eisner, Robert
    Kaustubh, Navin
    Declerck, Jerome
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4785 - +
  • [5] Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT
    McQuaid, Sarah J.
    Hutton, Brian F.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (06) : 1117 - 1123
  • [6] Respiration-averaged CT for attenuation correction in canine cardiac PET/CT
    Cook, Russell A. H.
    Carnes, Greg
    Lee, Ting-Yim
    Wells, R. Glenn
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (05) : 811 - 818
  • [7] Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT
    Sarah J. McQuaid
    Brian F. Hutton
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35 : 1117 - 1123
  • [8] Reducing radiation dose in rest-stress cardiac PET/CT by single poststress cine CT for attenuation correction: Quantitative validation
    Gould, K. Lance
    Pan, Tinsu
    Loghin, Catalin
    Johnson, Nils P.
    Sdringola, Stefano
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (05) : 738 - 745
  • [9] Attenuation correction in cardiac PET/CT with three different CT protocols: a comparison with conventional PET
    Souvatzoglou, Michael
    Bengel, Frank
    Busch, Raymonde
    Kruschke, Coletta
    Fernolendt, Helga
    Lee, Denise
    Schwaiger, Markus
    Nekolla, Stephan G.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (12) : 1991 - 2000
  • [10] Attenuation correction in cardiac PET/CT with three different CT protocols: a comparison with conventional PET
    Michael Souvatzoglou
    Frank Bengel
    Raymonde Busch
    Coletta Kruschke
    Helga Fernolendt
    Denise Lee
    Markus Schwaiger
    Stephan G. Nekolla
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 1991 - 2000