Performance of a 2-Story CLT House Subjected to Lateral Loads

被引:115
|
作者
Popovski, Marjan [1 ]
Gavric, Igor [1 ]
机构
[1] FPInnovations, Adv Bldg Syst, 2665 East Mall, Vancouver, BC V6T 1Z4, Canada
关键词
Cross-laminated timber; Full-scale tests; Cyclic tests; Seismic performance; Wood structures;
D O I
10.1061/(ASCE)ST.1943-541X.0001315
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A 2-story full-scale model of a cross-laminated timber (CLT) house was tested under quasi-static monotonic and cyclic loading. The primary objectives were to investigate 3D system performance of a CLT structure subjected to lateral loads in terms of lateral strength and deformability capacity, global behavior of the structure, frequency response of the structure before and after each test, and performance of anchoring connectors (hold-downs, brackets) and connections between CLT panels. The house was 6.0x4.8m in plan with a height of 4.8m. A total of five (one push-over and four cyclic) quasi-static tests were performed, one direction at a time. Parameters, such as the direction of loading, number of hold-downs, and number of screws in perpendicular wall-to-wall connections, were varied in the tests. The CLT structure performed according to the design objectives, with the ultimate resistance being almost identical in both directions. Failure mechanisms, i.e.,shear failure of nails in the brackets in the first story as a result of sliding and rocking of the CLT wall panels, were similar in all tests. Even after the maximum force was reached, no global instabilities of the house were detected. Torsion effects did not compromise the integrity, stability, or the lateral resistance of the building. The outcomes of the full-scale CLT house tests will be used for further analytical and numerical analyses to help the implementation of CLT as a structural system in the North American building codes and material standards. (C) 2015 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] 2-STORY LOG HOUSE IN UPLAND SOUTH
    OMALLEY, JR
    REHDER, JB
    [J]. JOURNAL OF POPULAR CULTURE, 1978, 11 (04): : 904 - 915
  • [2] GROWING TURKEYS IN A 2-STORY 3-STAGE HOUSE
    SELDERS, AW
    CUNNINGHAM, DL
    LONGHOUSE, AD
    [J]. TRANSACTIONS OF THE ASAE, 1980, 23 (04): : 950 - 954
  • [3] STAFFING LEVELS .2. 2-STORY APARTMENT-HOUSE FIRE
    OHAGAN, JT
    [J]. FIRE COMMAND, 1984, 51 (12): : 24 - 27
  • [4] Analytical Approach to Establishing the Elastic Behavior of Multipanel CLT Shear Walls Subjected to Lateral Loads
    Casagrande, Daniele
    Doudak, Ghasan
    Mauro, Luigi
    Polastri, Andrea
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (02)
  • [5] FEIBLEMAN,J 2-STORY WORLD
    CAIRNS, H
    [J]. AMERICAN SCHOLAR, 1973, 42 (03): : 476 - 483
  • [6] THE 2-STORY OUTHOUSE - WEIS,N
    FITZGERALD, D
    [J]. JOURNAL OF THE WEST, 1989, 28 (04) : 101 - 101
  • [7] TESTS OF ONE AND 2-STORY FLAT PLATE MODELS
    HARNDEN, CT
    [J]. JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1974, 100 (NST3): : 513 - 531
  • [8] Influence of Riverbed Scour on the Performance of Bridges Subjected to Lateral Seismic Loads
    Song, Shin-Tai
    Hu, Tzu-Fan
    Chiou, Ding-Jer
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (05) : 2251 - 2282
  • [9] Performance of Loop Connection in Precast Concrete Walls Subjected to Lateral Loads
    Vaghei, Ramin
    Hejazi, Farzad
    Firoozi, Ali Akbar
    Jaafar, Mohd Saleh
    [J]. INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2019, 17 (3A) : 397 - 426
  • [10] Performance of Loop Connection in Precast Concrete Walls Subjected to Lateral Loads
    Ramin Vaghei
    Farzad Hejazi
    Ali Akbar Firoozi
    Mohd Saleh Jaafar
    [J]. International Journal of Civil Engineering, 2019, 17 : 397 - 426