Purpose: To compare intensity of posterior capsule opacification (PCO) between the 1-piece and 3-piece haptic designs of an open-loop hydrophobic acrylic intraocular lens (IOL). Design: A randomized, patient- and examiner-masked clinical trial with intraindividual comparison. Participants: Fifty-two patients with bilateral age-related cataract (104 eyes). Methods: Each patient had cataract surgery in both eyes and received a 1-piece Acrysof IOL in one eye and a 3-piece Acrysof IOL in the fellow eye. Follow-up examinations were at 1 week, 1 month, 6 months, 1 year, and 2 years. Patients were examined at the slit lamp, visual acuity (VA) was determined, and standardized high-resolution digital retroillumination images of the posterior capsule were taken. The intensity of PCO was assessed subjectively at the slit lamp and objectively using automated image analysis software. Main Outcome Measure: Posterior capsule opacification score (scale, 0-10). Results: There was no significant difference between IOL styles in best-corrected VA, rhexis/IOL overlap, capsular folds, and amount of anterior capsule opacification during the follow-up period. One year postoperatively, the amount of regeneratory PCO was higher for the 1-piece Acrysof eyes (image analysis software score: 1.3) than for the 3-piece Acrysof eyes (score: 0.9; P = 0.002). However, 2 years postoperatively, there was no significant difference between the 2 IOL styles (1-piece: 1.5; 3-piece: 1.3; P = 0.3). Neodymium:yttrium-aluminum-garnet capsulotomy was not performed in the study. Conclusion: One year postoperatively, the 1-piece Acrysof showed slightly more regeneratory PCO than the 3-piece Acrysof. However, 2 years postoperatively, the barrier effect of the 1-piece design was comparable to that of the 3-piece haptic design, with low PCO intensity. (C) 2004 by the American Academy of Ophthalmology.
引用
收藏
页码:1840 / 1846
页数:7
相关论文
共 49 条
  • [1] Effect of 1-piece and 3-piece AcrySof intraocular lenses on the development of posterior capsule opacification after cataract surgery
    Bender, LE
    Nimsgern, C
    Jose, R
    Jayaram, H
    Spalton, DJ
    Tetz, MR
    Packard, RB
    Meacock, W
    Boyce, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (04): : 786 - 789
  • [2] Comparison of posterior capsule opacification between a 1-piece and a 3-piece microincision intraocular lens
    Prinz, Ana
    Vecsei-Marlovits, Pia Veronika
    Sonderhof, Dietrich
    Irsigler, Paul
    Findl, Oliver
    Weingessel, Birgit
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (01) : 18 - 22
  • [3] Posterior capsule opacification in rabbit eyes implanted with 1-piece and 3-piece hydrophobic acrylic intraocular lenses
    Werner, L
    Mamalis, N
    Izak, AM
    Pandey, SK
    Davis, BL
    Nilson, CD
    Weight, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04): : 805 - 811
  • [4] Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule
    Hayashi, K
    Hayashi, H
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (02): : 337 - 342
  • [5] Long-term effect of 1-Piece and 3-piece hydrophobic acrylic Intraocular lens on posterior capsule opacification - A randomized trial
    Leydolt, Christina
    Davidovic, Sofija
    Sacu, Stefan
    Menapace, Rupert
    Neumayer, Thomas
    Prinz, Ana
    Buehl, Wolf
    Findl, Oliver
    OPHTHALMOLOGY, 2007, 114 (09) : 1663 - 1669
  • [6] Comparison of tilt and decentration of 1-piece and 3-piece hydrophobic acrylic intraocular lenses
    Mutlu, FM
    Erdurman, C
    Sobaci, G
    Bayraktar, MZ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (02): : 343 - 347
  • [7] Posterior Capsule Opacification with the iMics1 NY-60 and AcrySof SN60WF 1-Piece Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial
    Leydolt, Christina
    Schriefl, Sabine
    Stifter, Eva
    Haszcz, Alexandra
    Menapace, Rupert
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (02) : 375 - 381
  • [8] Anterior segment parameters: Comparison of 1-piece and 3-piece acrylic foldable intraocular lenses
    Behrouz, Mahmoud Jabbarvand
    Kheirkhah, Ahmad
    Hashemian, Hesam
    Nazari, Rahman
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10): : 1650 - 1655
  • [9] Posterior Capsule pacification With the iMics1 NY-60 and AcrySof SN6OWF 1-Piece Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial
    Carifi, Gianluca
    Zygoura, Vasiliki
    Deshmukh, Rajesh R.
    Kopsachilis, Nikolaos
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (06) : 1317 - 1317
  • [10] Comparison of Nd:YAG capsulotomy rate between 1-piece and 3-piece acrylic intraocular lenses A STROBE-compliant article
    Kim, Sun Young
    Chung, Young Kwon
    Shin, Hye Young
    Lee, Mee Yon
    Lee, Young-Chun
    Kim, Su-Young
    MEDICINE, 2017, 96 (27)