Densely-folded spectral images of the CCD spectrometer working in the full 200-1000 nm wavelength range with high resolution

被引:0
|
作者
Chen, Yue-Rui [1 ]
Sun, Bin [1 ]
Han, Tao [1 ]
Kong, Yu-Fei [1 ]
Xu, Cong-Hui [1 ]
Zhou, Peng [1 ]
Li, Xiao-Fan [1 ]
Wang, Song-You [1 ]
Zheng, Yu-Xiang [1 ]
Chen, Liang-Yao [1 ]
机构
[1] Fudan Univ, State Key Lab Adv Photon Mat & Devices, Dept Opt Sci & Engn, Shanghai 200433, Peoples R China
关键词
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
引用
收藏
页码:250 / 250
页数:1
相关论文
共 8 条
  • [1] Densely folded spectral images of a CCD spectrometer working in the full 200-1000 nm wavelength range with high resolution
    Chen, YR
    Sun, B
    Han, T
    Kong, YF
    Xu, CH
    Zhou, P
    Li, XF
    Wang, SY
    Zheng, YX
    Chen, LY
    OPTICS EXPRESS, 2005, 13 (25): : 10049 - 10054
  • [2] Spectrometry - CCD spectrometer folds spectral images from 200 to 1000 nm
    Overton, G
    LASER FOCUS WORLD, 2006, 42 (02): : 42 - 43
  • [3] High quantum efficiency 200-1000 nm spectral response photodiodes with on-chip multiple high transmittance optical layers
    Koda, Yasumasa
    Kuroda, Rihito
    Sugawa, Shigetoshi
    2014 IEEE SENSORS, 2014, : 1664 - 1667
  • [4] Design and application of a high-precision, broad spectral range CCD-based absorption spectrometer with millisecond time resolution
    Steffen, Ronald
    Jackman, Keith
    Krausz, Elmars
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (07)
  • [5] HIGH-RESOLUTION ATMOSPHERIC TRANSMISSION CALCULATIONS DOWN TO 28.7 KM IN THE 200-243-NM SPECTRAL RANGE
    CANN, MWP
    NICHOLLS, RW
    EVANS, WFJ
    KOHL, JL
    KURUCZ, R
    PARKINSON, WH
    REEVES, EM
    APPLIED OPTICS, 1979, 18 (07): : 964 - 975
  • [6] IMAGING CHANNELED SPECTROGRAPH - A HIGH-RESOLUTION SPECTROMETER PROVIDING MULTIPLE SIMULTANEOUS 2-D MONOCHROMATIC IMAGES OVER A LARGE SPECTRAL RANGE
    KORENDYKE, CM
    APPLIED OPTICS, 1988, 27 (20): : 4187 - 4192
  • [7] High-resolution continuum-source electrothermal atomic absorption spectrometer for simultaneous multi-element determination in the spectral range of 190-780 nm
    Labusov, V. A.
    Boldova, S. S.
    Selunin, D. O.
    Semenov, Z. V.
    Vashchenko, P. V.
    Babin, S. A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (05) : 1005 - 1010
  • [8] Full-range ultrahigh-resolution spectral-domain optical coherence tomography in 1.7 μm wavelength region for deep-penetration and high-resolution imaging of turbid tissues
    Kawagoe, Hiroyuki
    Yamanaka, Masahito
    Makita, Shuichi
    Yasuno, Yoshiaki
    Nishizawa, Norihiko
    APPLIED PHYSICS EXPRESS, 2016, 9 (12)