Evaluation of Colilert-18® as an alternative method for monitoring total coliforms and Escherichia coli in some faecally polluted river waters

被引:0
|
作者
Brand, Amanda S. [1 ]
Barnes, Jo M. [1 ]
机构
[1] Univ Stellenbosch, Div Community Hlth, Fac Med & Hlth Sci, ZA-7600 Stellenbosch, South Africa
基金
新加坡国家研究基金会;
关键词
faecal pollution monitoring; health risk assessment; method comparison; polluted environmental waters; WESTERN-CAPE; CORRELATION-COEFFICIENT; IDENTIFICATION; CONTAMINATION; PLANKENBURG; ENUMERATION; INDICATOR; BERG;
D O I
10.2166/washdev.2014.040
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
The increase in numbers and contamination levels of faecally polluted water has resulted in shifts worldwide towards methods which enumerate faecal indicator bacteria faster. Rapid methods enable more timely remedial and preventative actions which protect the health of water users. However, especially in the developing world, straightforward methods are also preferred as they reduce the requirement for highly qualified analysts. This study investigates the feasibility of using the rapid, semi-automated enzyme substrate test Colilert-18 (R) instead of multiple-tube fermentation (MTF) in total coliform and Escherichia coli enumeration for South African river water, as one example of a surface water source carrying considerable faecal pollution, which needs monitoring. Spearman rank correlation coefficients (rho) of 0.83 and 0.86 were obtained for total coliforms and E. coli respectively, indicating Colilert-18 (R) performed acceptably in the pollution ranges encountered. A Bland-Altman plot further revealed that Colilert-18 (R) showed no significant difference (p > 0.05) from MTF values below 100,000 E. coli most probable number/100 mL (estimated true value). Above this level Colilert-18 (R) was found to progressively underestimate E. coli. This inadequacy of Colilert-18 (R) was considered acceptable from a health risk assessment viewpoint as such high counts should have sounded the alarm for preventative and corrective action irrespective of method inaccuracy.
引用
收藏
页码:604 / 611
页数:8
相关论文
共 18 条
  • [1] Evaluation of Colilert-18 for the detection of coliforms and Escherichia coli in tropical fresh water
    Chao, WL
    LETTERS IN APPLIED MICROBIOLOGY, 2006, 42 (02) : 115 - 120
  • [2] Evaluation of Colilert-18 for detection of coliforms and Eschericha coli in subtropical freshwater
    Chao, KK
    Chao, CC
    Chao, WL
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (02) : 1242 - 1244
  • [3] Comparison of Colilert-18 with miniaturised most probable number method for monitoring of Escherichia coli in bathing water
    Tiwari, Ananda
    Niemela, Seppo I.
    Vepsalainen, Asko
    Rapala, Jarkko
    Kalso, Seija
    Pitkanen, Tarja
    JOURNAL OF WATER AND HEALTH, 2016, 14 (01) : 121 - 131
  • [4] The use of Colilert-18, Colilert and Enterolert for the detection of faecal coliform, Escherichia coli and Enterococci in tropical marine waters, Trinidad and Tobago
    Ramoutar, Sheldon
    REGIONAL STUDIES IN MARINE SCIENCE, 2020, 40
  • [5] Marine bacteria cause false-positive results in the Colilert-18 rapid identification test for Escherichia coli in Florida waters
    Pisciotta, JM
    Rath, DF
    Stanek, PA
    Flanery, DM
    Harwood, VJ
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2002, 68 (02) : 539 - 544
  • [6] EVALUATION OF COLILERT-MARINE WATER FOR DETECTION OF TOTAL COLIFORMS AND ESCHERICHIA-COLI IN THE MARINE-ENVIRONMENT
    PALMER, CJ
    TSAI, YL
    LANG, AL
    SANGERMANO, LR
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1993, 59 (03) : 786 - 790
  • [7] Evaluation of commercial colilert18-quantitray® method by ISO techniques for enumeration and quantification of total coliforms and Escherichia coli in drinking-water of Buraidah, Saudi Arabia
    Al-Turki, A.
    El-Ziney, M.G.
    Journal of Applied Sciences, 2009, 9 (18) : 3357 - 3363
  • [8] Evaluation of a new medium for the enumeration of total coliforms and Escherichia coli in Japanese surface waters
    Kodaka, H.
    Mizuochi, S.
    Saito, M.
    Matsuoka, H.
    JOURNAL OF APPLIED MICROBIOLOGY, 2008, 104 (04) : 1112 - 1118
  • [9] Evaluation of a new medium for the enumeration of total coliforms and Escherichia coli in Japanese surface waters
    Kodaka, H.
    Mizuochi, S.
    Saito, M.
    Matsuoka, H.
    Journal of Applied Microbiology, 2008, 104 (04): : 1112 - 1118
  • [10] Effect of trout farming activity on the concentration of total coliforms and Escherichia coli in waters of the upper Savegre river basin, Costa Rica
    Retana, L. Marco
    Arias-Echandi, Maria Laura
    Barrantes, Gilbert
    REVISTA DE BIOLOGIA TROPICAL, 2023, 71