Evaluation of a novel pedicle probe for the placement of thoracic and lumbosacral pedicle screws

被引:13
|
作者
Grauer, JN
Vaccaro, AR
Brusovanik, G
Girardi, FP
Silveri, CP
Cammisa, FP
Kwon, BK
Beiner, JM
Albert, TJ
Hilibrand, AS
Scuderi, GJ
机构
[1] Jefferson Univ, Rothman Inst, Philadelphia, PA USA
[2] Yale Univ, Sch Med, Dept Orthopaed & Rehabil, New Haven, CT 06510 USA
[3] Hosp Special Surg, New York, NY USA
[4] Fair Oaks Orthopaed Associates, Fairfax, VA USA
[5] Univ British Columbia, Dept Orthopaed, Combined Neurosurg & Orthopaed Spine Program, Vancouver, BC V5Z 1M9, Canada
来源
关键词
spine; bone screws; spinal fusion; internal fixators; orthopaedic fixation devices;
D O I
10.1097/01.bsd.0000112046.36255.58
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Pedicle screw instrumentation is common in the lumbar spine and is gaining acceptance in the thoracic spine. The pedicle is generally cannulated with a gearshift probe or curette. SafePath (Mekanika, Boca Raton, FL) is an alternative pedicle probe designed for pedicle cannulation. This is a blunt-tipped, nonaggressive drill that seeks the cancellous portion of the pedicle. Objective: The objective of this study was to evaluate the accuracy of this device in comparison with techniques commonly used for pedicle cannulation. Methods: Four osteoligamentous fresh-frozen thoracic to sacral cadaveric spines were studied. The pedicles of one side of each cadaver were cannulated with the SafePath device. The contralateral pedicles were cannulated with either a gearshift probe or a 3-0 cervical curette. The accuracy of pedicle probe placement was evaluated by radiography, computed tomography (CT) scan, and direct observation via dissection. Results: By direct observation, 51 of 128 pedicles were violated (40%). There were not significant differences between the results obtained with the gearshift probe or curette; there were 2 of 22 lumbosacral violations (9%) and 14 of 45 thoracic violations (33%). With the SafePath device, there were 0 of 22 lumbosacral violations (0%) and 34 of 45 thoracic violations (76%). SafePath performed significantly better in the lumbar spine and significantly worse in the thoracic spine. The accuracy for determining pedicle violation was 88% for radiography and 85% for CT. Conclusions: The results of this in vitro study suggest that the SafePath device may represent an alternative to traditional pedicle cannulation techniques in the lumbosacral spine. However, the opposite is true in the thoracic spine, where SafePath performed significantly worse than traditional techniques.
引用
收藏
页码:492 / 497
页数:6
相关论文
共 50 条
  • [1] PLACEMENT OF THORACIC PEDICLE SCREWS
    Polly, David W., Jr.
    Yaszemski, Alexandra K.
    Jones, Kristen E.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2016, 6 (01):
  • [2] Placement of Percutaneous Thoracic Pedicle Screws Using NeuroNavigation
    Kakarla, Udaya K.
    Little, Andrew S.
    Chang, Steve W.
    Sonntag, Volker K. H.
    Theodore, Nicholas
    WORLD NEUROSURGERY, 2010, 74 (06) : 606 - 610
  • [3] Triggered electromyography for placement of thoracic pedicle screws: is it reliable?
    Amer F. Samdani
    Mark Tantorski
    Patrick J. Cahill
    Ashish Ranade
    Stephen Koch
    David H. Clements
    Randal R. Betz
    Jahangir Asghar
    European Spine Journal, 2011, 20 : 869 - 874
  • [4] Triggered electromyography for placement of thoracic pedicle screws: is it reliable?
    Samdani, Amer F.
    Tantorski, Mark
    Cahill, Patrick J.
    Ranade, Ashish
    Koch, Stephen
    Clements, David H.
    Betz, Randal R.
    Asghar, Jahangir
    EUROPEAN SPINE JOURNAL, 2011, 20 (06) : 869 - 874
  • [5] Stereotactic navigation for placement of pedicle screws in the thoracic spine
    Youkilis, AS
    Quint, DJ
    McGillicuddy, JE
    Papadopoulos, SM
    NEUROSURGERY, 2001, 48 (04) : 771 - 778
  • [7] Learning Curve for Placement of Thoracic Pedicle Screws in the Deformed Spine
    Samdani, Amer F.
    Ranade, Ashish
    Saidanha, Vilas
    Yondorf, Menacham Z.
    NEUROSURGERY, 2010, 66 (02) : 290 - 294
  • [8] Placement of Percutaneous Pedicle Screws
    Chao, Simon
    TECHNIQUES IN ORTHOPAEDICS, 2011, 26 (03) : 124 - 130
  • [9] Pedicle guide for thoracic pedicle screw placement
    Abode-Iyamah, Kingsley
    Stemper, Luke
    Rachman, Shane
    Schneider, Kelly
    Sick, Kathryn
    Hitchon, Patrick
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 10 (03) : 211 - 220
  • [10] Accuracy and Safety of Fluoroscopic Guided Percutaneous Pedicle Screws in Thoracic and Lumbosacral Spine
    Hansen-Algenstaedt, Nils
    Chiu, Chee Kidd
    Chan, Chris Yin Wei
    Lee, Chee Kean
    Schaefer, Christian
    Kwan, Mun Keong
    SPINE, 2015, 40 (17) : E954 - E963