Quality of intrapartum cardiotocography in twin deliveries

被引:6
|
作者
Bakker, PCAM [1 ]
Colenbrander, GI [1 ]
Verstraeten, AA [1 ]
Van Geijn, HP [1 ]
机构
[1] Vrije Univ Amsterdam, Ctr Med, Dept Obstet & Gynaecol, NL-1007 MB Amsterdam, Netherlands
关键词
twins; intrapartuni fetal heart rate monitoring; fetal signal loss; International Federation of Gynecology and Obstetrics Guidelines;
D O I
10.1016/j.ajog.2004.04.037
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: Intrapartum fetal heart rate (FHR) recordings in twins were compared for fetal signal loss durin- both stages of labor to assess the quality of these recordings by the method that had been used: external ultrasound or directly via a scalp electrode. Study design: Analysis of recordings collected between January 1, 1994, and January 1 2002 from consecutive twin deliveries at the Vrije Universiteit Medical Center in Amsterdam. One hundred seventy-two twins that delivered via the vaginal route were included in the study. FHR recordings had a duration of at least I hour before the birth of the second twin. Subdivision took place on the basis of the recording technique, ie, ultrasound or scalp electrode. FHR data was obtained with HP-M 1350 cardiotocographs. The status (pen oil, pen off. maternal signal) and the mode of the signals were acquired. The duration of pen lifts and maternal signals was divided by the total duration of the recording. Statistical analyses were performed with the Mann-Whitney U test and the Wilcoxon signed ranks test. Results: Recordings obtained via ultrasound demonstrated significantly more fetal signal loss than those obtained via the direct mode, particularly in the second stage. Approximately 26% to 33% of first stage and 41% to 63% of second stage ultrasound intrapartum FHR recordings in twins exceeded the International Federation of Gynecology and Obstetrics (FIGO) criteria for fetal signal loss. Conclusion: Intrapartum FHR monitoring Via ultrasound provides far poorer quality FHR signals than the direct mode. The direct mode deserves a more prominent position in fetal surveillance than it currently has. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:2114 / 2119
页数:6
相关论文
共 50 条
  • [1] The quality of intrapartum cardiotocography in preterm labor
    Faiz, Zohal
    van 't Hof, Eline
    Colenbrander, Gerard
    Lippes, Ralf
    Bakker, Petra
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2021, 224 (02) : S244 - S244
  • [2] The quality of intrapartum cardiotocography in preterm labour
    Faiz, Zohal
    Hof, Eline M. Van 't
    Colenbrander, Gerard J.
    Lippes, Ralf
    Bakker, Petra C. A. M.
    [J]. JOURNAL OF PERINATAL MEDICINE, 2022, 50 (01) : 74 - 81
  • [3] Intrapartum cardiotocography
    Zanardo, Vincenzo
    Straface, Gianluca
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2024, 231 (03) : 114 - 114
  • [4] Intrapartum surveillance: Computer cardiotocography
    Arduini, D
    Giannini, F
    Magenes, G
    Signorini, MG
    Stroppolo, A
    [J]. PERINATAL MEDICINE OF THE NEW MILLENNIUM, 2001, : 1217 - 1223
  • [5] INTRAPARTUM CARDIOTOCOGRAPHY AND THE EXPERT WITNESS
    UMSTAD, MP
    PERMEZEL, M
    PEPPERELL, RJ
    [J]. AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1994, 34 (01): : 20 - 23
  • [6] Intrapartum cardiotocography -: the dilemma of interpretational variation
    Palomaki, Outi
    Luukkaala, Tiina
    Luoto, Riikka
    Tuimala, Risto
    [J]. JOURNAL OF PERINATAL MEDICINE, 2006, 34 (04) : 298 - 302
  • [7] Prepartum and intrapartum cardiotocography in breach presentation
    Santosa, H
    Kunzel, W
    [J]. GYNAKOLOGE, 1997, 30 (09): : 720 - 725
  • [8] Fetal Outcome with Abnormal Intrapartum Cardiotocography
    Mairaj, Naila
    Perveen, Shagufta
    Maqbool, Muniba
    Alvi, Asiya Nawaz
    Mushtaq, Rashida
    [J]. PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2020, 14 (04): : 2060 - 2061
  • [9] Cardiotocography and ST analysis for intrapartum fetal monitoring
    Leipala, Jaana
    Ojala, Kati
    Stefanovic, Vedran
    Makela, Marjukka
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2012, 91 (04) : 518 - 518
  • [10] Cardiotocography patterns and risk of intrapartum fetal acidemia
    Holzmann, Malin
    Wretler, Stina
    Cnattingius, Sven
    Nordstrom, Lennart
    [J]. JOURNAL OF PERINATAL MEDICINE, 2015, 43 (04) : 473 - 479