A New Method of Microcatheter Heat-Forming for Cerebral Aneurysmal Coiling Using Stereolithography Three-Dimensional Printed Hollow Vessel Models

被引:7
|
作者
Nakajima, Sadao [1 ]
Sakamoto, Makoto [1 ]
Yoshioka, Hiroki [2 ]
Uno, Tetsuji [1 ]
Kurosaki, Masamichi [1 ]
机构
[1] Tottori Univ, Div Neurosurg, Dept Brain & Neurosci, Fac Med, Yonago, Tottori 6838503, Japan
[2] Tottori Prefectural Cent Hosp, Dept Neurosurg, Tottori 6800901, Japan
关键词
cerebral aneurysm; coil embolization; endovascular surgery; microcatheter shape; stereolithography 3D printer;
D O I
10.33160/yam.2021.02.001
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background To perform successful coil embolization of cerebral aneurysms, it is crucial to make an appropriately shaped microcatheter tip for an aneurysm and its parent artery. So far, we manually shaped a mandrel by referencing two-dimensional (2D) images of a rotation digital subtraction angiography (DSA) on a computer screen. However, this technique requires a lot of experience, and often involves trial and error. Recently, there have been increasing reports of manual mandrel shaping using a full-scale three-dimensional (3D) model of an aneurysm and its parent artery output by various types of 3D printer. We have further developed this method by producing a hollow model of an aneurysm and its parent artery with a stereolithography 3D printer and inserting a mandrel inside the model to fit and stabilize a microcatheter tip. Methods Based on digital imaging and communications in medicine (DICOM) data obtained by rotational DSA, 3D images of an aneurysm and its parent artery were created and converted into standard triangulated language (STL) data. A hollow model was produced by extruding the STL data outward in the normal direction, and then a hole was made at the tip of the aneurysm using these STL data. We output these STL data to a stereolithography 3D printer. After cleaning and sterilizing the model, the mandrel was inserted in the direction of the parent artery through the hole made in the tip of the aneurysm and pushed in, creating the ideal mandrel shape. Twelve cases (14 aneurysms) were included in this study. A microcatheter tip was shaped by this method for patients who were scheduled to undergo coil embolization for an unruptured aneurysm. Results In 13 of the 14 aneurysms, the microcatheter was easily guided into the aneurysms in one or two trials, the position of the microcatheter tip in the aneurysm was appropriate, and the stability during coil embolization was high. Conclusion Our method differs from the conventional one in that a hollow model made of resin is produced with a stereolithography 3D printer and that the mandrel is shaped by inserting it retrogradely into the hollow model. Using our new method, it will be possible to shape the tip of a microcatheter suitable for safe and stable coil embolization without relying on an operator's experience.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 6 条
  • [1] Microcatheter shaping using three-dimensional printed models for intracranial aneurysm coiling
    Xu, Y.
    Tian, W.
    Wei, Z.
    Li, Y.
    Gao, X.
    Li, W.
    Dong, B.
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (03) : 308 - 310
  • [2] Tailor-made shaping of microcatheters using three-dimensional printed vessel models for endovascular coil embolization
    Ishibashi, Toshihiro
    Takao, Hiroyuki
    Suzuki, Takashi
    Yuki, Ichiro
    Kaku, Shogo
    Kan, Issei
    Nishimura, Kengo
    Suzuki, Tomoaki
    Watanabe, Mitsuyosi
    Karagiozov, Kostadin
    Murayama, Yuichi
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 77 : 59 - 63
  • [3] Using a new three-dimensional CUBIC tissue-clearing method to examine the brain during experimental cerebral malaria
    Matsuo-Dapaah, Julia
    Lee, Michelle Sue Jann
    Ishii, Ken J.
    Tainaka, Kazuki
    Coban, Cevayir
    [J]. INTERNATIONAL IMMUNOLOGY, 2021, 33 (11) : 587 - 594
  • [4] Simulation of blood flow and vessel deformation in three-dimensional, patient-specific models of the cardiovascular system using a novel method for fluid-solid interactions
    Figueroa, A
    Vignon-Clementel, I
    Jansen, K
    Hughes, TJR
    Taylor, CA
    [J]. Fluid Structure Interaction and Moving Boundary Problems, 2005, 84 : 143 - 152
  • [5] New Method of Interpretation of Hole-to-Surface Electrical Measurements using Three-Dimensional Models: Application to Concealed Massive Sulfides in the Cyprus Ophiolitic Complex.
    Poirmeur, Christophe
    Le Masne, Dominique
    [J]. 1600, (53):
  • [6] Three-dimensional local grid refinement for block-centered finite-difference groundwater models using iteratively coupled shared nodes: a new method of interpolation and analysis of errors
    Mehl, S
    Hill, MC
    [J]. ADVANCES IN WATER RESOURCES, 2004, 27 (09) : 899 - 912