Functionalization of PEO layer formed on Ti-15Mo for biomedical application

被引:11
|
作者
Lesniak, Katarzyna [1 ]
Plonka, Joanna [1 ]
Smiga-Matuszowicz, Monika [2 ]
Brzychczy-Wloch, Monika [3 ]
Kazek-Kesik, Alicja [1 ]
机构
[1] Silesian Tech Univ, Fac Chem, Dept Inorgan Chem Analyt Chem & Electrochem, B Krzywoustego St 6, PL-44100 Gliwice, Poland
[2] Silesian Tech Univ, Fac Chem, Dept Phys Chem & Technol Polymers, Gliwice, Poland
[3] Jagiellonian Univ, Dept Microbiol, Med Coll, Krakow, Poland
关键词
bacteria; hybrid coating; PSBA; surface treatment; titanium alloy; STAPHYLOCOCCUS-EPIDERMIDIS; SUSTAINABLE RELEASE; MODIFIED TITANIUM; BONE TISSUE; VANCOMYCIN; IMPLANT; DEGRADATION; AMOXICILLIN; ALLOY; MICROPARTICLES;
D O I
10.1002/jbm.b.34504
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the present work, deposition of poly(sebacic anhydride) PSBA loaded by amoxicillin, cefazolin, or vancomycin on a previously anodized Ti-15Mo surface is presented. PSBA loaded by the drug was deposited so as not to lose the functionality of the porous oxide layer microstructure. The morphology was evaluated using scanning electron microscopy, surface roughness, and wettability. The drug concentration was evaluated using high-performance liquid chromatography. It was determined that the drugs were loaded into coatings in the range of 35.2-122.87 mu g/cm(2) of Ti sample. The drugs released more than 16% after 0.5 hr of the hybrid coating immersion in artificial saliva. After 3days, the PSBA coatings were degraded by 51.3 mol %, and after 7days by 77.8 mol %, which makes it possible to load the material by different, biologically active substances. An antimicrobial investigation of Staphylococcus aureus (DSM 24167) and Staphylococcus epidermidis (ATCC 700296) confirmed the activity of the hybrid layers against the pathogens. Hybrid layer with vancomycin best inhibits the adhesion of the bacteria, whereas coatings with amoxicillin and cefazolin showed a much better bactericidal activity. In this article, the difference in the obtained results is discussed, as well as the possibility of the application of this functional material in biomedicine.
引用
收藏
页码:1568 / 1579
页数:12
相关论文
共 50 条
  • [1] Allvac Ti-15Mo
    陈永红
    上海钢研, 2005, (04) : 50 - 50
  • [2] The Influence of the Electrolyte Nature and PEO Process Parameters on Properties of Anodized Ti-15Mo Alloy Intended for Biomedical Applications
    Banakh, Oksana
    Snizhko, Lyubov
    Journot, Tony
    Gay, Pierre-Antoine
    Csefalvay, Catherine
    Kalinichenko, Oleg
    Girin, Oleg
    Marger, Laurine
    Durual, Stephane
    METALS, 2018, 8 (05):
  • [3] Surface characterisation of Ti-15Mo alloy modified by a PEO process in various suspensions
    Kazek-Kesik, Alicja
    Dercz, Grzegorz
    Kalemba, Izabela
    Suchanek, Katarzyna
    Kukharenko, Andrey I.
    Korotin, Danila M.
    Michalska, Joanna
    Krzakala, Agnieszka
    Piotrowski, Jerzy
    Kurmaev, Ernst Z.
    Cholakh, Seif O.
    Simka, Wojciech
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 39 : 259 - 272
  • [4] Preparation and bioactive surface modification of the microwave sintered porous Ti-15Mo alloys for biomedical application
    Xu, Jilin
    Zhang, Jinlong
    Bao, Luzi
    Lai, Tao
    Luo, Junming
    Zheng, Yufeng
    SCIENCE CHINA-MATERIALS, 2018, 61 (04) : 545 - 556
  • [5] Diffusion of Oxygen and Nitrogen in the Ti-15Mo Alloy used for Biomedical Applications
    Severino Martins Junior, Jose Roberto
    Nogueira, Renata Abdallah
    de Araujo, Raul Oliveira
    Grandini, Carlos Roberto
    DIFFUSION IN SOLIDS AND LIQUIDS VII, 2012, 326-328 : 696 - 701
  • [6] Hybrid oxide-polymer layer formed on Ti-15Mo alloy surface enhancing antibacterial and osseointegration functions
    Kazek-Kesik, Alicja
    Jaworska, Joanna
    Krok-Borkowicz, Malgorzata
    Golda-Cepa, Monika
    Pastusiak, Malgorzata
    Brzychczy-Wloch, Monika
    Pamula, Elzbieta
    Kotarba, Andrzej
    Simka, Wojciech
    SURFACE & COATINGS TECHNOLOGY, 2016, 302 : 158 - 165
  • [7] Cryogenic turning of Ti-15Mo alloy
    Juan C. C. Rubio
    Virgílio P. Ricci
    Alessandro R. Rodrigues
    Andrea M. Kliauga
    Carlos E. H. Ventura
    The International Journal of Advanced Manufacturing Technology, 2025, 137 (7) : 4129 - 4141
  • [8] Influence of surface modification on the apatite formation and corrosion behavior of Ti and Ti-15Mo alloy for biomedical applications
    Sasikumar, Y.
    Rajendran, N.
    MATERIALS CHEMISTRY AND PHYSICS, 2013, 138 (01) : 114 - 123
  • [9] Electrochemical and biological characterization of coatings formed on Ti-15Mo alloy by plasma electrolytic oxidation
    Kazek-Kesik, Alicia
    Krok-Borkowicz, Malgorzata
    Pamula, Elzbieta
    Simka, Wojciech
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 43 : 172 - 181
  • [10] On the nature of the omega tri-layer periodicity in rapidly cooled Ti-15Mo
    Bennett, J. M.
    Barnard, J. S.
    Stone, H. J.
    Midgley, P. A.
    Rugg, D.
    Jones, N. G.
    SCRIPTA MATERIALIA, 2015, 107 : 79 - 82