Defect morphology, bone thickness, exposure settings and examiner experience affect the diagnostic accuracy of standardized digital periapical radiographic images but not of cone beam computed tomography in the detection of peri-implant osseous defects: An in vitro study

被引:19
|
作者
Pelekos, George [1 ]
Tse, Judy M. N. [1 ]
Ho, Dominic [1 ]
Tonetti, Maurizio S. [1 ]
机构
[1] Univ Hong Kong, Fac Dent, Div Periodontol & Implant Dent, Hong Kong, Peoples R China
关键词
cone beam computed tomography; diagnostic accuracy; periapical radiograph; peri-implant defect; peri-implantitis; diagnosis; CONSENSUS REPORT; EUROPEAN WORKSHOP; CLINICAL-RESEARCH; DENTISTRY; DISEASES; PREVALENCE; GUIDELINES; THERAPY;
D O I
10.1111/jcpe.13200
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aims To investigate the effect of defect morphology, bone thickness and examiner experience on the accuracy to detect the presence, the type and the depth of peri-implant defects with digital periapical radiographs (PAs) and cone beam computed tomography (CBCT) in an in vitro model. Methods Thirty six implants were placed in fresh porcine rib bone with different types of standardized defects while sites with no defect served as control. Fourteen masked examiners evaluated 324 PAs and 108 CBCT images. The presence and type of defect, the location of the bottom of the defect and the location of first bone-to-implant contact were recorded. The sensitivity, specificity, accuracy, positive and negative predictive values were calculated for each type of defect using actual measurements as the gold standard. Results The diagnostic accuracy for PAs was affected by defect morphology, exposure time, thickness of bone walls and the level of experience of the examiner. The overall diagnostic accuracy of CBCT was high (>96%) for all types of defects. Conclusion Cone beam computed tomography showed better diagnostic accuracy in the detection of peri-implant defects, this can be attributed to the fact that CBCT seems to be less affected by variables that contribute to the poorer performance of PAs.
引用
收藏
页码:1294 / 1302
页数:9
相关论文
共 13 条
  • [1] Evaluation of peri-implant bone defects on cone-beam computed tomography and the diagnostic accuracy of detecting these defects on panoramic images
    Oshima, Takayuki
    Asaumi, Rieko
    Ogura, Shin
    Kawai, Taisuke
    IMAGING SCIENCE IN DENTISTRY, 2024, 54 (02) : 171 - 180
  • [2] Effectiveness of Periapical Radiography Versus Cone Beam Computed Tomography with Different Kilovoltage Settings in the Detection of Chemically Created Peri-implant Bone Defects: An In Vitro Study
    Pinheiro, Lucas Rodrigues
    Scarfe, William C.
    de Oliveira Sales, Marcelo Augusto
    Gaia, Bruno Felipe
    Gonzalez Cortes, Arthur Rodriguez
    Paraiso Cavalcanti, Marcelo Gusmao
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 741 - 750
  • [3] Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection
    Saberi, Bardia Vadiati
    Khosravifard, Negar
    Ghandari, Farnaz
    Hadinezhad, Arash
    IMAGING SCIENCE IN DENTISTRY, 2019, 49 (04) : 265 - 272
  • [4] Efficacy of two radiographic algorithms for detection of peri-implant bone defects on cone-beam computed tomography scans
    Yousefi, Faezeh
    Heidari, Ali
    Ehsani, Azita
    Farhadian, Maryam
    Ehsani, Marzieh
    BMC ORAL HEALTH, 2025, 25 (01):
  • [5] Accuracy of cone beam computed tomography in assessing peri-implant bone defect regeneration: a histologically controlled study in dogs
    Fienitz, Tim
    Schwarz, Frank
    Ritter, Lutz
    Dreiseidler, Timo
    Becker, Juergen
    Rothamel, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) : 882 - 887
  • [6] Effect of field of view in the detection of chemically created peri-implant bone defects in bovine ribs using cone beam computed tomography: an in vitro study
    Pinheiro, Lucas Rodrigues
    Gaia, Bruno Felipe
    Oliveira de Sales, Marcelo Augusto
    Umetsubo, Otavio Shoiti
    Santos, Oseas, Jr.
    Paraiso Cavalcanti, Marcelo Gusmao
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (01): : 69 - 77
  • [7] Intra- and inter-observer agreements in detecting peri-implant bone defects between periapical radiography and cone beam computed tomography: A clinical study
    Zhang, Chu-Nan
    Zhu, Yu
    Fan, Lin-Feng
    Zhang, Xiao
    Jiang, Yin-Hua
    Gu, Ying-Xin
    JOURNAL OF DENTAL SCIENCES, 2021, 16 (03) : 948 - 956
  • [8] Zirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study
    Kuusisto, Niina
    Abushahba, Faleh
    Syrjanen, Stina
    Huumonen, Sisko
    Vallittu, Pekka
    Narhi, Timo
    DENTOMAXILLOFACIAL RADIOLOGY, 2023, 52 (08)
  • [9] Accuracy of cone-beam computed tomography, dental magnetic resonance imaging, and intraoral radiography for detecting peri-implant bone defects at single zirconia implantsAn in vitro study
    Hilgenfeld, Tim
    Juerchott, Alexander
    Deisenhofer, Ulrich Karl
    Krisam, Johannes
    Rammelsberg, Peter
    Heiland, Sabine
    Bendszus, Martin
    Schwindling, Franz Sebastian
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (09) : 922 - 930
  • [10] Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
    Alaa Shafiek Nomier
    Yousria Salah El-Din Gaweesh
    Maha R. Taalab
    Shaimaa Abu El Sadat
    BMC Oral Health, 22