Development of totally implantable pulsatile biventricular assist device

被引:14
|
作者
Park, CY
Park, JW
Lee, JJ
Kim, WE
Hwang, CM
Om, KS
Choi, J
Kim, J
Shim, EB
Jo, YH
Min, BG
机构
[1] Seoul Natl Univ, Coll Med, Dept Biomed Engn, Seoul 110744, South Korea
[2] Seoul Natl Univ, Med Res Ctr, Inst Med & Biol Engn, Seoul 110744, South Korea
[3] Seoul Natl Univ, Grad Sch, Interdisciplinary Program Med & Biol Engn Major, Seoul 110744, South Korea
[4] Biomedlab Co, Seoul, South Korea
[5] Kumoh Natl Univ Technol, Kumi, South Korea
[6] Natl Canc Ctr, Div Basic Sci, Biomed Engn Branch, Koyang, South Korea
关键词
biventricular assist device; moving-actuator; pulsatile; implantable; circulatory assist device;
D O I
10.1046/j.1525-1594.2003.07177.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Approximately 10% to 15% of all patients implanted with left ventricular assist devices (LVADs) have required right heart support with another device. The necessity of aggressive biventricular support has already been proposed. Therefore, the totally implantable biventricular assist device (BVAD) was developed. The width of the BVAD main body was 87 mm, the thickness 67 mm, and the height 106 mm, while the weight was 785 g. The automatic control algorithm was developed to prevent lung edema and atrial rupture.
引用
收藏
页码:119 / 123
页数:5
相关论文
共 50 条
  • [1] Development of a totally implantable pulsatile centrifugal pump as a ventricular assist device
    Chou, NK
    Wang, SS
    Lin, YH
    Shyu, TJ
    Hsieh, KH
    Jan, GJ
    Chu, SH
    [J]. ARTIFICIAL ORGANS, 2001, 25 (08) : 603 - 606
  • [2] Current status on the development of a totally implantable biventricular assist device:: The Baylor Gyro BVAD
    Linneweber, J
    Nonaka, K
    Ichikawa, S
    Ishitoya, H
    Motomura, T
    Nosé, Y
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 2004, 52 (01): : 1 - 5
  • [3] Pulsatile biventricular assist device and an absent mitral valve
    Gosev, Igor
    Mick, Stephanie L.
    Couper, Gregory S.
    Shekar, Prem S.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (02): : E23 - E25
  • [4] Totally implantable intrathoracic ventricular assist device
    Mussivand, TV
    Masters, RG
    Hendry, PJ
    Keon, WJ
    [J]. ANNALS OF THORACIC SURGERY, 1996, 61 (01): : 444 - 447
  • [5] The total artificial heart and implantable biventricular assist device
    Min B.G.
    Sun K.
    [J]. Journal of Artificial Organs, 2002, 5 (3) : 147 - 148
  • [6] IMPLANTABLE BIVENTRICULAR ASSIST DEVICE: FIRST IN VIVO RESULTS
    Wimmer, A.
    Schmid, T.
    Vodermayer, B.
    Gmeiner, H.
    Kunz, A.
    Lehle, K.
    Schmid, C.
    Welz, A.
    Hirzinger, G.
    Schiller, W.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (08): : 608 - 609
  • [7] COMPLETELY IMPLANTABLE BIVENTRICULAR ASSIST DEVICE FOR DESTINATION THERAPY
    Wimmer, A.
    Schmid, T.
    Vodermayer, B.
    Gmeiner, H.
    Schiller, W.
    Lehle, K.
    Schmid, C.
    Welz, A.
    Hirzinger, G.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (07): : 469 - 469
  • [8] Development of the Baylor Gyro permanently implantable centrifugal blood pump as a biventricular assist device
    Nonaka, K
    Linneweber, J
    Ichikawa, S
    Yoshikawa, T
    Kawahito, S
    Mikami, M
    Motomura, T
    Ishitoya, H
    Nishimura, I
    Oestmann, D
    Glueck, J
    Schima, H
    Wolner, E
    Shinohara, T
    Nosé, Y
    [J]. ARTIFICIAL ORGANS, 2001, 25 (09) : 675 - 682
  • [9] Biventricular amputation for biventricular pulsatile assist device implantation in patients with severe ventricular septal perforation
    Vollroth, Marcel
    Seeburger, Joerg
    Mohr, Friedrich W.
    Borger, Michael A.
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 17 (01) : 202 - 204
  • [10] THE IMPLANTABLE BIVENTRICULAR DLR ASSIST DEVICE: FIRST IN VITRO AND IN VIVO RESULTS
    Schmid, T.
    Schiller, W.
    Vodermayer, B.
    Liepsch, D.
    Welz, A.
    Hirzinger, G.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (07): : 425 - 425