Objective. Next generation online and real-time adaptive radiotherapy workflows require precise particle transport simulations in sub-second times, which is unfeasible with current analytical pencil beam algorithms (PBA) or Monte Carlo (MC) methods. We present a deep learning based millisecond speed dose calculation algorithm (DoTA) accurately predicting the dose deposited by mono-energetic proton pencil beams for arbitrary energies and patient geometries. Approach. Given the forward-scattering nature of protons, we frame 3D particle transport as modeling a sequence of 2D geometries in the beam's eye view. DoTA combines convolutional neural networks extracting spatial features (e.g. tissue and density contrasts) with a transformer self-attention backbone that routes information between the sequence of geometry slices and a vector representing the beam's energy, and is trained to predict low noise MC simulations of proton beamlets using 80 000 different head and neck, lung, and prostate geometries. Main results. Predicting beamlet doses in 5 +/- 4.9 ms with a very high gamma pass rate of 99.37 +/- 1.17% (1%, 3 mm) compared to the ground truth MC calculations, DoTA significantly improves upon analytical pencil beam algorithms both in precision and speed. Offering MC accuracy 100 times faster than PBAs for pencil beams, our model calculates full treatment plan doses in 10-15 s depending on the number of beamlets (800-2200 in our plans), achieving a 99.70 +/- 0.14% (2%, 2 mm) gamma pass rate across 9 test patients. Significance. Outperforming all previous analytical pencil beam and deep learning based approaches, DoTA represents a new state of the art in data-driven dose calculation and can directly compete with the speed of even commercial GPU MC approaches. Providing the sub-second speed required for adaptive treatments, straightforward implementations could offer similar benefits to other steps of the radiotherapy workflow or other modalities such as helium or carbon treatments.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Sub-second speed proton dose calculation with Monte Carlo accuracy using deep learning
    Pastor-Serrano, O.
    Perko, Z.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S10 - S11
  • [2] Fast Monte Carlo dose calculation based on deep learning
    Fu, Jiaqi
    Bai, Jingfeng
    Liu, Yanfang
    Ni, Cheng
    [J]. 2020 13TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2020), 2020, : 721 - 726
  • [3] Validation of a deep learning-based material estimation model for Monte Carlo dose calculation in proton therapy
    Chang, Chih-Wei
    Zhou, Shuang
    Gao, Yuan
    Lin, Liyong
    Liu, Tian
    Bradley, Jeffrey D.
    Zhang, Tiezhi
    Zhou, Jun
    Yang, Xiaofeng
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (21):
  • [4] FRoG dose computation meets Monte Carlo accuracy for proton therapy dose calculation in lung
    Magro, Giuseppe
    Mein, Stewart
    Kopp, Benedikt
    Mastella, Edoardo
    Pella, Andrea
    Ciocca, Mario
    Mairani, Andrea
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 86 : 66 - 74
  • [5] Improving proton dose calculation accuracy by using deep learning
    Wu, Chao
    Nguyen, Dan
    Xing, Yixun
    Montero, Ana Barragan
    Schuemann, Jan
    Shang, Haijiao
    Pu, Yuehu
    Jiang, Steve
    [J]. MACHINE LEARNING-SCIENCE AND TECHNOLOGY, 2021, 2 (01):
  • [6] Improving Proton Dose Calculation Accuracy Using Deep Learning
    Wu, C.
    Nguyen, D.
    Xing, Y.
    Montero, A. Barragan
    Schuemann, J.
    Pu, Y.
    Jiang, S.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E121 - E121
  • [7] Evaluation of Accuracy and Performance of a Fast Monte Carlo Code for Dose Calculation in Proton Therapy
    Jabbari, K.
    Roayaei, M.
    Saeedi, A.
    [J]. CLINICAL ONCOLOGY, 2011, 23 (03) : S40 - S40
  • [8] Dose calculation of proton therapy based on Monte Carlo and empirical formula
    Yu, Yue
    Chen, Zhi
    [J]. RADIATION PROTECTION DOSIMETRY, 2023, 199 (02) : 124 - 133
  • [9] Fast Monte Carlo dose calculation in proton therapy
    Holmes, Jason
    Feng, Hongying
    Zhang, Lian
    Fix, Michael K.
    Jiang, Steve B.
    Liu, Wei
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (17):
  • [10] Macro Monte Carlo for dose calculation of proton beams
    Fix, Michael K.
    Frei, Daniel
    Volken, Werner
    Born, Ernst J.
    Aebersold, Daniel M.
    Manser, Peter
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07): : 2027 - 2044