Detection sensitivity correction calculation model and application of photoelectric detection target in four-screen intersection testing system

被引:14
|
作者
Li, Hanshan [1 ]
Zhang, Xiaoqian [1 ]
Zhang, Xuewei [1 ]
Lu, Liping [1 ]
机构
[1] Xian Technol Univ, Sch Elect & Informat Engn, Xian 710021, Peoples R China
基金
中国国家自然科学基金;
关键词
Four-screen intersection testing system; Photoelectric detection target; Detection sensitivity; Array photoelectric detection receiver; Projectile;
D O I
10.1016/j.measurement.2021.109281
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In four-screen intersection testing system, the inconsistency in the detection sensitivity of the photoelectric detection target leads to the errors in the time value extraction for each photoelectric detection target. To improve the detection sensitivity and the measurement accuracy, we propose the array photoelectric detection receiver to design a new photoelectric detection target, set up a new method for calculating the detection sensitivity of the photoelectric detection target based on the detection field of view, detection screen thickness, detection distance, and the target's geometry, and present a detection sensitivity correction method for fourscreen intersection testing system by introducing the sensitivity correction factor. Through the comparative experiments, we present the comparative test data when the projectile passes through different positions of the field of view of photoelectric detection target for different detection distances. The results show that the proposed detection sensitivity correction model has the ability to improve the measurement accuracy.
引用
收藏
页数:8
相关论文
共 22 条