Identification and Characterization of Imaging Technique Errors and Artifacts Using Anterior-Segment OCT for Irido-Corneal Angle Evaluations in Glaucoma

被引:7
|
作者
Shi, Yue [1 ]
Marion, Kenneth M. [1 ]
Jenkins, Dennis [1 ]
Sadda, SriniVas [1 ,2 ]
Le, Phuc, V [1 ,2 ]
Chopra, Vikas [1 ,2 ]
机构
[1] Doheny Eye Inst, 1355 San Pablo St, Los Angeles, CA 90033 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Ophthalmol, Los Angeles, CA 90095 USA
来源
OPHTHALMOLOGY GLAUCOMA | 2019年 / 2卷 / 03期
关键词
D O I
10.1016/j.ogla.2019.02.006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Anterior-segment OCT (AS-OCT) platforms provide noninvasive and quantifiable evaluations of anterior chamber angle (ACA) anatomy. Although these ACA measurements have been validated with high repeatability and reproducibility, there is a paucity of data previously published regarding the technique errors and artifacts (TEA) that may occur during imaging of the ACA. The purpose of this study was to report on the types and frequency of imaging TEA that are seen in ACA evaluation of a large cohort of patients with open-angle glaucoma. Design: Retrospective, cross-sectional design. Participants: Images were obtained with AS-OCT from 5082 eyes of 2541 patients with glaucoma and were reviewed at the Doheny Image Reading Center (DIRC). Methods: Images had been captured using AS-OCT devices from 4 different manufacturers (Zeiss Cirrus [Oberkochen, Germany], Heidelberg Spectralis [Heidelberg, Germany], Optovue RTVue [Fremont, CA], or Zeiss Visante). All images were analyzed by 2 independent and certified DIRC image readers for angle opening distance under Schwalbe's line (SL-AOD), and then re-reviewed by a DIRC-certified principal investigator to adjudicate nonconsensus measurements. Images were defined to have TEA when image readers were unable to confidently measure the SL-AOD. Main Outcome Measures: Type and frequency of TEA in the AS-OCT image. Results: Of 5082 eyes reviewed, 208 images (4.09%) were found to have TEA that restricted proper visualization of irido-corneal angle structures and measurements of SL-AOD. The most common TEA was that the image readers were unable to identify Schwalbe's line (74% of TEA images). Other common TEA included poor visualization of the anterior iris surface (15%), misaligned scan location (11%), irregular corneal irregularities (5%), and illumination-related pupillary abnormalities (4%). Conclusions: This large-scale study presents the types and frequency of TEA found in AS-OCT-derived angle images. More than 95% of the images reviewed were usable for the quantification of irido-corneal angle measurements. Knowing the common types of TEA may help in enhancing the training of both human image readers and in the design of automated algorithms to improve image acquisition and image interpretation parameters. This will become especially useful as AS-OCT becomes more widely used in clinical practice for anterior chamber assessment. (C) 2019 by the American Academy of Ophthalmology
引用
收藏
页码:136 / 144
页数:9
相关论文
共 13 条
  • [1] Quantification of Imaging Artifacts using Anterior Segment Optical Coherence Tomography (ASOCT) for Irido-Corneal Angle Evaluations
    Lock, Amy
    Shi, Yue
    Jenkins, Dennis
    Sadda, Srinivas R.
    Chopra, Vikas
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [2] Irido-corneal angle and fundus documentation using a novel dual-mode imaging probe
    Mani, Baskaran
    Shinoj, V. K.
    Murukeshan, V. M.
    Aung, Tin
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [3] Imaging Angle Recession Using Anterior Segment OCT
    Elubous, Khaled Ali
    Saheb, Hady
    [J]. OPHTHALMOLOGY GLAUCOMA, 2024, 7 (01): : 103 - 103
  • [4] Anterior-Segment Retinoblastoma Mimicking Pseudoinflammatory Angle-Closure Glaucoma: Review of the Literature and the Important Role of Imaging
    Saket, R. R.
    Mafee, M. F.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (08) : 1607 - 1609
  • [5] Wide dynamic range digital aberrometry and anterior-segment imaging using a dualmode MHz swept-source OCT
    Ke, Mengyuan
    Kumar, Abhishek
    Meyer, Bjoern
    Ansbaek, Thor
    Leitgeb, Rainer
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [6] Anterior segment OCT imaging in opaque grafts with secondary glaucoma following tectonic penetrating keratoplasty for perforated corneal ulcers
    T Dada
    B M Shah
    S J Bali
    N Bansal
    A Panda
    M Vanathi
    [J]. Eye, 2011, 25 : 1522 - 1524
  • [7] Anterior segment OCT imaging in opaque grafts with secondary glaucoma following tectonic penetrating keratoplasty for perforated corneal ulcers
    Dada, T.
    Shah, B. M.
    Bali, S. J.
    Bansal, N.
    Panda, A.
    Vanathi, M.
    [J]. EYE, 2011, 25 (11) : 1522 - 1524
  • [8] Anterior chamber angle features in primary congenital glaucoma infants using hand-held anterior segment-oct
    Weam Abdeen
    Amanne F. Esmael
    Ghada Gawdat
    Dina El-Fayoumi
    [J]. Eye, 2022, 36 : 1238 - 1245
  • [9] Anterior chamber angle features in primary congenital glaucoma infants using hand-held anterior segment-oct
    Abdeen, Weam
    Esmael, Amanne F.
    Gawdat, Ghada
    El-Fayoumi, Dina
    [J]. EYE, 2022, 36 (06) : 1238 - 1245
  • [10] Constructing a Biomechanical Model of the Anterior Chamber Angle Using Anterior Segment OCT Imaging: The Chinese American Eye Study
    Xu, Benjamin
    Israelson, Paul
    Wang, Dandan
    Varma, Rohit
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)