On-line coupling of gas diffusion to capillary electrophoresis

被引:62
|
作者
Kuban, P [1 ]
Karlberg, B [1 ]
机构
[1] Univ Stockholm, Dept Analyt Chem, S-10691 Stockholm, Sweden
关键词
anions; capillary electrophoresis; gas diffusion;
D O I
10.1016/S0039-9140(97)00131-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
On-line gas diffusion has been coupled to a capillary electrophoresis system (CE) via a specially designed interface. The sample is merged with a modifying solution, e.g., a strong acid, in a flow system to transform the analytes of interest into their respective gaseous forms. These transformed, gaseous analytes permeate through a PTFE membrane into an acceptor stream comprising of a tris-buffer. The continuously flowing acceptor stream is led into an injector forming an integrated part of a flow injection analysis (FIA) system. The sample receiving carrier stream in the FIA system, a chromate buffer, brings the sample, 50 mu l, to the FIA-CE interface into which one end of a separation capillary has been inserted. A small portion of the injected sample enters the capillary (electrokinetic injection) and separation takes place. A UV detector is placed at the other capillary end and a run potential of 25 kV is applied to two platinum electrodes positioned in the flow system. Multiple sample injections can be performed in one uninterrupted electrophoretic run. A typical sampling frequency is 15 h(-1); each run may result in quantitation of at least five anions. The overall repeatability is in the range 1.8-3.6% (RSD). The technique has been applied to the analysis of real samples such as soft drinks, vinegar and wine. Selective discrimination of anions which are unable to form volatile species is accomplished. No off-line sample pre-treatment is needed. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:477 / 484
页数:8
相关论文
共 50 条
  • [2] On-line coupling of PIXE with capillary zone electrophoresis (CZE)
    Vogt, J
    Vogt, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 108 (1-2): : 133 - 135
  • [3] On-line coupling of in vivo microdialysis with capillary electrophoresis/electrochemistry
    Zhou, JX
    Heckert, DM
    Zuo, H
    Lunte, CE
    Lunte, SM
    ANALYTICA CHIMICA ACTA, 1999, 379 (03) : 307 - 317
  • [4] Automatic on-line coupling of supercritical fluid extraction and capillary electrophoresis
    Mardones, C
    Ríos, A
    Valcárcel, M
    ANALYTICAL CHEMISTRY, 2000, 72 (22) : 5736 - 5739
  • [5] On-line Coupling of Microdialysis with Capillary Electrophoresis Using a Cross Interface
    Tuma, Petr
    Opekar, Frantisek
    Jurka, Vlastimil
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE MODERN ELECTROCHEMICAL METHODS XXXVIII, 2018, : 240 - 244
  • [6] On-line coupling of capillary electrochromatography and capillary electrophoresis with NMR and ES-MS
    Bayer, E
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 215 : U91 - U91
  • [7] Determination of chlorite in drinking water by on-line coupling of capillary isotachophoresis and capillary zone electrophoresis
    Praus, P
    TALANTA, 2004, 62 (05) : 977 - 982
  • [8] On-line coupling of microdialysis sampling with microchip-based capillary electrophoresis
    Huynh, BH
    Fogarty, BA
    Martin, RS
    Lunte, SM
    ANALYTICAL CHEMISTRY, 2004, 76 (21) : 6440 - 6447
  • [9] On-line preconcentration of sample in capillary electrophoresis
    Hui, X
    Ying, Z
    Yu, XD
    Chen, HY
    PROGRESS IN CHEMISTRY, 2005, 17 (03) : 377 - 383
  • [10] On-line preconcentration methods for capillary electrophoresis
    Osbourn, DM
    Weiss, DJ
    Lunte, CE
    ELECTROPHORESIS, 2000, 21 (14) : 2768 - 2779