Clinical Evaluation of Free-Breathing Contrast-Enhanced T1w MRI of the Liver using Pseudo Golden Angle Radial k-Space Sampling

被引:13
|
作者
Hedderich, Dennis M. [1 ,2 ]
Weiss, Kilian [3 ]
Spiro, Judith E. [1 ,4 ]
Giese, Daniel [1 ]
Beck, Gabriele M. [5 ]
Maintz, David [1 ]
Persigehl, Thorsten [1 ]
机构
[1] Univ Hosp Cologne, Dept Radiol, Kerpener Str 62, D-50937 Cologne, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Diagnost & Intervent Neuroradiol, Munich, Germany
[3] Philips Healthcare, Hamburg, Germany
[4] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, Munich, Germany
[5] Philips Healthcare, Best, Netherlands
关键词
MR-imaging; liver; free-breathing; radial; pseudo golden angle; GRADIENT-ECHO SEQUENCE; MAGNETIC-RESONANCE; GADOXETIC ACID; GADOBENATE DIMEGLUMINE; IMAGE QUALITY; DISODIUM; CT; ACQUISITION; CARCINOMA; DIAGNOSIS;
D O I
10.1055/s-0044-101263
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Contrast-enhanced T1-weighted MR imaging of the liver is typically acquired using breath-hold techniques to reduce motion artifacts and to allow for optimal diagnostic image quality. Insufficient breath-holds during MR data collection can cause severe reduction of image quality up to the point of being non-diagnostic. The aim of this study was to evaluate the subjective and objective clinical image quality of a novel free-breathing radial k-space sampling MR technique. Materials and Methods Consent for this study was given by the local IRB committee. 86 patients who underwent both breath-hold (BH) and free-breathing (FB) late-phase contrast T1w-FS-FFE liver MRI using conventional BH Cartesian (Cartesian-eTHRIVE) and FB "pseudo golden angle" radial k-space sampling (Radial-eTHRIVE) were included in this retrospective analysis. Subjective analysis comprised 5-point Likert scale ratings (1 = very good; 5 = non-diagnostic) for "artifact impact", "anatomic sharpness", "vessel sharpness", "contrast impression", and "overall diagnostic quality". Relative signal intensities in different ROIs were compared between Cartesian-eTHRIVE and Radial-eTHRIVE. For statistical differences paired Wilcoxon test and paired t-test have been performed (p < 0.05). Results The MR scan time was significantly longer for FB Radial-eTHRIVE (2min, 54 s) compared to BH Cartesian-eTHRIVE (0 min 15 s). Cartesian-eTHRIVE demonstrated a superior subjective contrast impression and objective measurements revealed an increased lesion-to-liver-contrast for hypointense liver lesions (Hypo-LTLC: 0.33 +/- 0.19 vs. 0.20 +/- 0.11; p = 0.000), while no difference was observed for hyperintense liver lesions (Hyper-LTLC). Subjective evaluation showed superior anatomic sharpness ratings by both readers for Radial-eTHRIVE. Most importantly, in a subgroup analysis of patients who were unable to perform adequate breath-holds, free-breathing Radial-eTHRIVE still demonstrated good subjective image quality. Conclusion Free-breathing, radial k-space sampling T1w MRI of the liver delivers high diagnostic image quality, especially in patients who are unable to adequately perform breath-hold maneuvers. Thus, Radial-eTHRIVE can be an important clinical alternative in patients with impaired respiration status.
引用
收藏
页码:601 / 609
页数:9
相关论文
共 43 条
  • [1] Free-breathing contrast-enhanced T1-weighted gradient-echo imaging with radial k-space sampling for paediatric abdominopelvic MRI
    Chandarana, Hersh
    Block, Kai T.
    Winfeld, Matthew J.
    Lala, Shailee V.
    Mazori, Daniel
    Giuffrida, Emalyn
    Babb, James S.
    Milla, Sarah S.
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (02) : 320 - 326
  • [2] Free-breathing contrast-enhanced T1-weighted gradient-echo imaging with radial k-space sampling for paediatric abdominopelvic MRI
    Hersh Chandarana
    Kai T. Block
    Matthew J. Winfeld
    Shailee V. Lala
    Daniel Mazori
    Emalyn Giuffrida
    James S. Babb
    Sarah S. Milla
    [J]. European Radiology, 2014, 24 : 320 - 326
  • [3] Free-Breathing Contrast-Enhanced Multiphase MRI of the Liver Using a Combination of Compressed Sensing, Parallel Imaging, and Golden-Angle Radial Sampling
    Chandarana, Hersh
    Feng, Li
    Block, Tobias K.
    Rosenkrantz, Andrew B.
    Lim, Ruth P.
    Babb, James S.
    Sodickson, Daniel K.
    Otazo, Ricardo
    [J]. INVESTIGATIVE RADIOLOGY, 2013, 48 (01) : 10 - 16
  • [4] Free-breathing dynamic contrast-enhanced MRI of the abdomen and chest using a radial gradient echo sequence with K-space weighted image contrast (KWIC)
    Kim, Kyung Won
    Lee, Jeong Min
    Jeon, Yong Sik
    Kang, Sung Eun
    Baek, Jee Hyun
    Han, Joon Koo
    Choi, Byung Ihn
    Bang, Yung-Jue
    Kiefer, Berthold
    Block, Kai Tobias
    Ji, Hyunjun
    Bauer, Simon
    Kim, Chin
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (05) : 1352 - 1360
  • [5] Free-breathing dynamic contrast-enhanced MRI of the abdomen and chest using a radial gradient echo sequence with K-space weighted image contrast (KWIC)
    Kyung Won Kim
    Jeong Min Lee
    Yong Sik Jeon
    Sung Eun Kang
    Jee Hyun Baek
    Joon Koo Han
    Byung Ihn Choi
    Yung-Jue Bang
    Berthold Kiefer
    Kai Tobias Block
    Hyunjun Ji
    Simon Bauer
    Chin Kim
    [J]. European Radiology, 2013, 23 : 1352 - 1360
  • [6] Free-breathing dynamic contrast-enhanced MRI for assessment of pulmonary lesions using golden-angle radial sparse parallel imaging
    Chen, Lihua
    Liu, Daihong
    Zhang, Jiuquan
    Xie, Bing
    Zhou, Xiaoyue
    Grimm, Robert
    Huang, Xuequan
    Wang, Jian
    Feng, Li
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (02) : 459 - 468
  • [7] Investigating the Influence of Flip Angle and k-Space Sampling on Dynamic Contrast-Enhanced MRI Breast Examinations
    Ledger, Araminta E. W.
    Borri, Marco
    Pope, Romney J. E.
    Scurr, Erica D.
    Wallace, Toni
    Richardson, Cheryl
    Usher, Marianne
    Allen, Steven
    Wilson, Robin M.
    Thomas, Karen
    deSouza, Nandita M.
    Leach, Martin O.
    Schmidt, Maria A.
    [J]. ACADEMIC RADIOLOGY, 2014, 21 (11) : 1394 - 1401
  • [8] Comparison of lung lesion assessment using free-breathing dynamic contrast-enhanced 1.5-T MRI with a golden-angle radial stack-of-stars VIBE sequence and CT
    Chen, Jiliang
    Tang, Qunfeng
    Song, Yang
    Tao, Xinwei
    Chen, Jingwen
    Zhao, Jun
    Jiang, Zhen
    [J]. ACTA RADIOLOGICA, 2024, 65 (08) : 930 - 939
  • [9] "One-Stop Shop": Free-Breathing Dynamic Contrast-Enhanced Magnetic Resonance Imaging of the Kidney Using Iterative Reconstruction and Continuous Golden-Angle Radial Sampling
    Riffel, Philipp
    Zoellner, Frank G.
    Budjan, Johannes
    Grimm, Robert
    Block, Tobias K.
    Schoenberg, Stefan O.
    Hausmann, Daniel
    [J]. INVESTIGATIVE RADIOLOGY, 2016, 51 (11) : 714 - 719
  • [10] Accelerated k-space shift calibration for free-breathing stack-of-radial MRI quantification of liver fat and R2*
    Zhong, Xiaodong
    Armstrong, Tess
    Gao, Chang
    Nickel, Marcel D.
    Han, Fei
    Dale, Brian M.
    Li, Xinzhou
    Kafali, Sevgi G.
    Hu, Peng
    Wu, Holden H.
    Deshpande, Vibhas
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (01) : 281 - 291