The role of prosthetic abutment material on the stress distribution in a maxillary single implant-supported fixed prosthesis

被引:24
|
作者
Peixoto, Hugo Eduardo [1 ]
Bordin, Dimorvan [2 ]
Del Bel Cury, Altair A. [2 ]
da Silva, Wander Jose [2 ]
Faot, Fernanda [3 ]
机构
[1] Latin Amer Inst Res & Educ Dent, Implantol Team, Curitiba, Parana, Brazil
[2] Univ Estadual Campinas, Dept Prosthodont & Periodontol, Piracicaba Dent Sch, Limeira Ave 901, BR-13414903 Piracicaba, SP, Brazil
[3] Univ Fed Pelotas, Dept Restorat Dent, Sch Dent, Goncalves Chaves 457,2nd Floor, BR-96015560 Pelotas, RS, Brazil
关键词
Dental implants; Dental implant-abutment design; Finite element analysis; Titanium; Zirconia; FINITE-ELEMENT-ANALYSIS; TITANIUM ABUTMENTS; CHEWING SIMULATION; FRACTURE STRENGTH; DENTAL IMPLANTS; BENDING MOMENTS; CLINICAL-TRIAL; ZIRCONIA; DESIGNS; CONNECTIONS;
D O I
10.1016/j.msec.2016.04.004
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Purpose: Evaluate the influence of abutment's material and geometry on stress distribution in a single implant supported prosthesis. Materials and Methods: Three-dimensional models were made based on tomographic slices of the upper middle incisor area, in which a morse taper implant was positioned and a titanium (Ti) or zirconia (ZrN) universal abutments was installed. The commercially available geometry of titanium (T) and zirconia (Z) abutments were used to draw two models, TM1 and ZM1 respectively, which served as control groups. These models were compared with 2 experimental groups were the mechanical properties of Z were applied to the titanium abutment (TM2) and vice versa for the zirconia abutment (ZM2). Subsequently, loading was simulated in two steps, starting with a preload phase, calculated with the respective friction coefficients of each materials, followed by a combined preload and chewing force. The maximum von Mises stress was described. Data were analyzed by two-way ANOVA that considered material composition, geometry and loading (p < 0.05). Results: Titanium and zirconia abutments showed similar von Mises stresses in the mechanical part of the four models. The area with the highest concentration of stress was the screw thread, following by the screw body. The highest stress levels occurred in screw thread was observed during the preloading phase in the ZM1 model (931 MPa); and during the combined loading in the TM1 model (965 MPa). Statistically significant differences were observed for loading, the material x loading interaction, and the loading x geometry interaction (p < 0.05). Preloading contributed for 77.89% of the stress (p < 0.05). There were no statistically significant differences to the other factors (p > 0.05). Conclusion: The screw was the piece most intensely affected, mainly through the preload force, independent of the abutment's material. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 96
页数:7
相关论文
共 50 条
  • [1] Stress distribution related to implant-supported prosthesis material
    Stegaroiu, R
    Kusakari, H
    Nishiyama, S
    Miyakawa, O
    [J]. JOURNAL OF DENTAL RESEARCH, 1997, 76 : 3316 - 3316
  • [2] Stress distribution in implant-supported prosthesis with external and internal implant-abutment connections
    Goiato, Marcelo Coelho
    Pesqueira, Aldieris Alves
    Falcon-Antenucci, Rosse Mary
    dos Santos, Daniela Micheline
    Haddad, Marcela Filie
    Bannwart, Lisiane Cristina
    Moreno, Amalia
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (02) : 283 - 288
  • [4] Microleakage at Implant Abutment and Prosthesis Interface in Cemented Implant-Supported Prosthesis
    Kumari, Soni
    Jadhav, Manish Shivaji
    Gupta, Vishal
    Isaac, Tarun Koshy
    Subramanium, Angel
    Kumar, Vinit
    [J]. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (06): : S1679 - S1681
  • [5] The effect of veneering materials on stress distribution in implant-supported fixed prosthetic restorations
    Çiftçi, Y
    Canay, S
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2000, 15 (04) : 571 - 582
  • [6] THE INFLUENCE OF CANTILEVER LENGTH AND IMPLANT INCLINATION ON STRESS DISTRIBUTION IN MAXILLARY IMPLANT-SUPPORTED FIXED DENTURES
    Bevilacqua, Marco
    Tealdo, Tiziano
    Menini, Maria
    Pera, Francesco
    Mossolov, Alexei
    Drago, Carl
    Pera, Paolo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (01): : 5 - 13
  • [7] Influence of Implant Inclination and Prosthetic Abutment Type on the Biomechanics of Implant-Supported Fixed Partial Dentures
    Poletto-Neto, Victorio
    Wentz Tretto, Pedro Henrique
    Zen, Bruno Massucato
    Bacchi, Atais
    Fernandes dos Santos, Mateus Bertolini
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (05) : 343 - 349
  • [8] Implant-supported fixed dental prosthesis with a microlocking implant prosthetic system: A clinical report
    Choi, Jae-Won
    Lee, Jin-Ju
    Bae, Eun-Bin
    Huh, Jung-Bo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 15 - 19
  • [9] Abutment selection in implant-supported fixed prosthodontics
    Giglio, GD
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 1999, 19 (03) : 233 - 241
  • [10] Influence of Abutment Material on the Stress of Implant-supported All-ceramic Single Crown
    高少怀
    李智勇