摘要
Purpose: Intraoperative measurement of the aortic valve (AV) gradient in patients undergoing cardiac surgery is routinely performed using transesophageal echocardiography (TEE). In patients with severe aortic stenosis (AS), TEE Doppler beam alignment with the blood flow through the stenotic valve may be inaccurate, resulting in an underestimation of the AV gradient. We describe here the use of epiaortic echocardiography as an alternative to TEE for the intraoperative evaluation of AS. Clinical features: A patient diagnosed with severe AS (peak pressure gradient by transthoracic echocardiography: 108 mmHg) was undergoing AV replacement. In contrast, intraoperative TEE examination performed prior to bypass showed only a mild pressure gradient across the AV (peak pressure gradient: 38 mmHg). In order to resolve the conflicting information, epiaortic echocardiography was used to measure the AV gradient, confirming severe AS (peak pressure gradient: 98 mmHg). Most likely, Doppler beam alignment through the stenotic valve was more parallel to blood flow using epiaortic echocardiography, thus revealing the true pressure gradient. Conclusion: Intraoperative epiaortic measurement of AV gradients can be successfully performed in patients where TEE may be inaccurate due to difficulty in aligning a Doppler beam with the transvalvular blood flow.
引用
收藏
页码:293 / 296
页数:4
相关论文
共 32 条
  • [1] Discrepancy between intraoperative transesophageal echocardiography and postoperative transthoracic echocardiography in assessing congenital valve surgery
    Honjo, Osami
    Kotani, Yasuhiro
    Osaki, Satoru
    Fujita, Yasufumi
    Suezawa, Takanori
    Tateishi, Atsushi
    Ishino, Kozo
    Kawada, Masaaki
    Akagi, Teiji
    Sano, Shunji
    [J]. ANNALS OF THORACIC SURGERY, 2006, 82 (06): : 2240 - 2246
  • [2] Usefulness of intraoperative epiaortic echocardiography to resolve discrepancy between transthoracic and transesophageal measurements of aortic valve gradient — a case reportL’utilité de l’échocardiographie épiaortique peropératoire dans l’élimination des écarts entre les mesures transthoraciques et transœsophagiennes du gradient valvulaire aortique — une étude de cas
    Thomas Edrich
    Stanton K. Shernan
    Brian Smith
    Holger K. Eltzschig
    [J]. Canadian Journal of Anaesthesia, 2003, 50 (3) : 293 - 296
  • [3] Grading Aortic Stenosis With Mean Gradient and Aortic Valve Area: A Comparison Between Preoperative Transthoracic and Precardiopulmonary Bypass Transesophageal Echocardiography
    Whitener, George
    Sivak, Joseph
    Akushevich, Igor
    Samad, Zainab
    Swaminathan, Madhav
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (05) : 1254 - 1259
  • [4] A quadricuspid aortic valve diagnosed by transesophageal echocardiography: Report of a case
    Takashi Watanabe
    Yasuyuki Hosoda
    Shiro Sasaguri
    Yumiko Aikawa
    [J]. Surgery Today, 1998, 28 : 1102 - 1104
  • [5] A quadricuspid aortic valve diagnosed by transesophageal echocardiography: Report of a case
    Watanabe, T
    Hosoda, Y
    Sasaguri, S
    Aikawa, Y
    [J]. SURGERY TODAY-THE JAPANESE JOURNAL OF SURGERY, 1998, 28 (10): : 1102 - 1104
  • [6] Clinical Trial Report: The Predictive Value of Intraoperative Transesophageal Echocardiography for Aortic Valve Repair
    Ahmad H.
    Lang R.M.
    [J]. Current Cardiovascular Imaging Reports, 2010, 3 (5) : 249 - 251
  • [7] The value of transthoracic and transesophageal echocardiography for the diagnosis of the native aortic infective endocarditis valve complications: a case report and literature review
    Molnar, Adrian
    Sacui, Diana
    Manole, Simona
    Radulescu, Amanda
    Beyer, Ruxandra
    [J]. MEDICAL ULTRASONOGRAPHY, 2016, 18 (02) : 253 - 256
  • [8] Efficacy of intraoperative transesophageal echocardiography in a case of protamine shock during transcatheter aortic valve implantation
    Akihisa Kataoka
    Yusuke Watanabe
    Shutaro Seki
    Shintaro Takamura
    Hirofumi Hioki
    Hiroyuki Kyono
    Shigehito Sawamura
    Ken Kozuma
    [J]. JA Clinical Reports, 2 (1)
  • [9] Efficacy of intraoperative transesophageal echocardiography in a case of protamine shock during transcatheter aortic valve implantation
    Kataoka, Akihisa
    Watanabe, Yusuke
    Seki, Shutaro
    Takamura, Shintaro
    Hioki, Hirofumi
    Kyono, Hiroyuki
    Sawamura, Shigehito
    Kozuma, Ken
    [J]. JA CLINICAL REPORTS, 2016, 2
  • [10] Transesophageal echocardiography yields larger values than transthoracic in measurements of aortic annulus. Implications for percutaneous aortic valve implantation
    Detaint, D.
    Messika-Zeitoun, D.
    Brochet, E.
    Iung, B.
    Himbert, D.
    Vahanian, A.
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 : 623 - 624