Low-cost potentiometric paper-based analytical device based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for point-of-care copper(ii) determination

被引:13
|
作者
Kamel, Ayman H. [1 ,2 ]
Amr, Abd El-Galil E. [3 ,4 ]
Almehizia, Abdulrahman A. [3 ]
Elsayed, Elsayed A. [5 ,6 ]
Moustafa, Gaber O. [7 ]
机构
[1] Coll Sci, Chem Dept, Sokheer 32038, Bahrain
[2] Ain Shams Univ, Fac Sci, Dept Chem, Cairo 11566, Egypt
[3] King Saud Univ, Coll Pharm, Pharmaceut Chem Dept, Riyadh 11451, Saudi Arabia
[4] Natl Res Ctr, Appl Organ Chem Dept, Giza 12622, Egypt
[5] King Saud Univ, Fac Sci, Bioprod Res Dept, Zool Dept, Riyadh 11451, Saudi Arabia
[6] Natl Res Ctr, Chem Nat & Microbial Prod Dept, Dokki 12622, Egypt
[7] Natl Res Ctr, Dept Peptide Chem, Cairo, Egypt
关键词
ION-SELECTIVE ELECTRODE; MOLECULARLY IMPRINTED POLYMERS; MOLAR DETECTION LIMIT; SENSING PLATFORM; ASS-ISE; SENSORS; WATER; CU2+; MICROELECTRODE; SAMPLES;
D O I
10.1039/d1ra04712d
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A simple, cost-effective, portable and disposable paper-based analytical device is designed and fabricated for copper(ii) determination. All solid-state ion-selective electrodes (ISEs) for copper and a Ag/AgCl reference electrode were constructed and optimized on the paper substrate. The copper electrodes were built using carbon nano-tube ink as a conductive substrate and an ion-to electron transducer. A suitable polymeric membrane is drop-cast on the surface of the conductive carbon ink window. The copper-sensing membrane is based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for copper detection. Under the optimized conditions, the presented all-solid-state paper-based Cu2+-ISEs showed a Nernstian response toward Cu2+ ions in 30 mM MES buffer, pH 7.0 over the linear range of 5.0 x 10(-7)-1.0 x 10(-3) M with a limit of detection of 8.0 x 10(-8) M. The copper-based sensors exhibited rapid detection of Cu2+ ions with a short response time (<10 s). The selectivity pattern of these new ionophores towards Cu2+ ions over many common mono-, di- and trivalent cations was evaluated using the modified separate solution method (MSSM). The presented paper-based analytical device exhibited good intra-day and inter day precision. The presented tool was successfully applied for trace Cu2+ detection in real samples of serum and whole blood collected from different children with autism spectrum disorder. The data obtained by the proposed potentiometric method were compared with those obtained by the inductively-coupled plasma (ICP) as a reference method. The presented copper paper-based analytical-device can be considered as an attractive tool for point-of-care copper determination because of its affordability, vast availability, and self-pumping ability, particularly when combined with potentiometric detection.
引用
收藏
页码:27174 / 27182
页数:9
相关论文
共 11 条
  • [1] A simple and low-cost paper-based device for simultaneous determination of hematocrit and hemoglobin levels in point-of-care settings
    Ram, Rishi
    Kumar, Dharmendra
    Paik, Pradip
    Sarkar, Arnab
    PHYSICS OF FLUIDS, 2023, 35 (12)
  • [2] Point-of-care paper-based analytical device for potentiometric detection of myoglobin as a cardiovascular disease biomarker
    Almehizia, Abdulrahman A.
    Naglah, Ahmed M.
    Alrasheed, Lamees S.
    Alanazi, Mashael G.
    Amr, Abdel El-Galil E.
    Kamel, Ayman H.
    RSC ADVANCES, 2023, 13 (22) : 15199 - 15207
  • [3] A paper-based photoelectrochemical immunoassay for low-cost and multiplexed point-of-care testing
    Wang, Panpan
    Ge, Lei
    Ge, Shenguang
    Yu, Jinghua
    Yan, Mei
    Huang, Jiadong
    CHEMICAL COMMUNICATIONS, 2013, 49 (32) : 3294 - 3296
  • [4] A Paper-Based Multiplexed Transaminase Test for Low-Cost, Point-of-Care Liver Function Testing
    Pollock, Nira R.
    Rolland, Jason P.
    Kumar, Shailendra
    Beattie, Patrick D.
    Jain, Sidhartha
    Noubary, Farzad
    Wong, Vicki L.
    Pohlmann, Rebecca A.
    Ryan, Una S.
    Whitesides, George M.
    SCIENCE TRANSLATIONAL MEDICINE, 2012, 4 (152)
  • [5] A novel low-cost and simple fabrication technique for a paper-based analytical device using super glue
    Kang, Hyo-eun
    Bui, The Huy
    Han, Won
    Lee, Yong-Ill
    Shin, Joong Ho
    ANALYTICA CHIMICA ACTA, 2024, 1329
  • [6] A novel, simple and low-cost paper-based analytical device for colorimetric detection of Cronobacter spp.
    Sun, Luhong
    Jiang, Yujun
    Pan, Ruili
    Li, Mingyu
    Wang, Rui
    Chen, Sihan
    Fu, Shiqian
    Man, Chaoxin
    ANALYTICA CHIMICA ACTA, 2018, 1036 : 80 - 88
  • [7] A paper-based chemiresistive biosensor employing single-walled carbon nanotubes for low-cost, point-of-care detection
    Shen, Yu
    Thien-Toan Tran
    Modha, Sidharth
    Tsutsui, Hideaki
    Mulchandani, Ashok
    BIOSENSORS & BIOELECTRONICS, 2019, 130 : 367 - 373
  • [8] A low-cost microfluidic paper-based analytical device (μPAD) with column chromatography preconcentration for the determination of paraquat in vegetable samples
    Chaikhan, Pilaipan
    Udnan, Yuthapong
    Sananmuang, Ratana
    Ampiah-Bonney, Richmond J.
    Chaiyasith, Wipharat Chuachuad
    MICROCHEMICAL JOURNAL, 2020, 159
  • [9] A Point-of-Care Paper-based Fingerstick Transaminase Test: Toward Low-cost "Lab-on-a-Chip" Technology for the Developing World
    Pollock, Nira R.
    Colby, Donn
    Rolland, Jason P.
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2013, 11 (05) : 478 - 482
  • [10] Smartphone-based point-of-care multiplexed-genes detection of Mycobacterium tuberculosis on a low-cost paper/polymer hybrid microfluidic device
    Tavakoli, Hamed
    Sun, Jianjun
    Li, XiuJun
    2023 IEEE BIOSENSORS CONFERENCE, BIOSENSORS, 2023,