Reliability of laser Doppler, near-infrared spectroscopy and Doppler ultrasound for peripheral blood flow measurements during and after exercise in the heat

被引:14
|
作者
Choo, Hui C. [1 ]
Nosaka, Kazunori [1 ]
Peiffer, Jeremiah J. [2 ]
Ihsan, Mohammed [1 ,3 ]
Yeo, Chow C. [1 ]
Abbiss, Chris R. [1 ]
机构
[1] Edith Cowan Univ, Sch Med & Hlth Sci, Ctr Exercise & Sports Sci Res, Joondalup, WA, Australia
[2] Murdoch Univ, Sch Psychol & Exercise Sci, Murdoch, WA, Australia
[3] Singapore Sports Inst, Sports Physiol Dept, Singapore, Singapore
关键词
Coefficient of variation; cutaneous vascular conductance; reproducibility; muscle oxygenation; MUSCLE OXYGENATION; SKELETAL-MUSCLE; SKIN; ACCLIMATION; TEMPERATURE; INTENSITY; RESPONSES; VOLUME; REPRODUCIBILITY; STRESS;
D O I
10.1080/02640414.2016.1235790
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study examined the test-retest reliability of near-infrared spectroscopy (NIRS), laser Doppler flowmetry (LDF) and Doppler ultrasound to assess exercise-induced haemodynamics. Nine men completed two identical trials consisting of 25-min submaximal cycling at first ventilatory threshold followed by repeated 30-s bouts of high-intensity (90% of peak power) cycling in 32.8 +/- 0.4 degrees C and 32 +/- 5% relative humidity (RH). NIRS (tissue oxygenation index [TOI] and total haemoglobin [tHb]) and LDF (perfusion units [PU]) signals were monitored continuously during exercise, and leg blood flow was assessed by Doppler ultrasound at baseline and after exercise. Cutaneous vascular conductance (CVC; PU/mean arterial pressure (MAP)) was expressed as the percentage change from baseline (% CVCBL). Coefficients of variation (CVs) as indicators of absolute reliability were 18.7-28.4%, 20.2-33.1%, 42.5-59.8%, 7.8-12.4% and 22.2-30.3% for PU, CVC, % CVCBL, TOI and tHb, respectively. CVs for these variables improved as exercise continued beyond 10 min. CVs for baseline and post-exercise leg blood flow were 17.8% and 10.5%, respectively. CVs for PU, tHb (r(2) = 0.062) and TOI (r(2) = 0.002) were not correlated (P > 0.05). Most variables demonstrated CVs lower than the expected changes (35%) induced by training or heat stress; however, minimum of 10 min exercise is recommended for more reliable measurements.
引用
收藏
页码:1715 / 1723
页数:9
相关论文
共 50 条
  • [1] CALF BLOOD-FLOW AND POSTURE - DOPPLER ULTRASOUND MEASUREMENTS DURING AND AFTER EXERCISE
    VANLEEUWEN, BE
    BARENDSEN, GJ
    LUBBERS, J
    DEPATER, L
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1992, 72 (05) : 1675 - 1680
  • [2] Oxygenation analysis by near-infrared reflection spectroscopy - Correlation to laser doppler flow
    Kuebler, WM
    Plesnila, N
    Rinecker, M
    Goetz, A
    [J]. FASEB JOURNAL, 1998, 12 (04): : A6 - A6
  • [3] Analysis of brain oxygenation by near-infrared reflection spectroscopy and correlation to laser Doppler flow
    Kuebler, WM
    Plesnila, N
    Rinecker, M
    Goetz, AE
    [J]. JOURNAL OF VASCULAR RESEARCH, 1998, 35 : 71 - 71
  • [4] Effect Of Exercise In Heat On Near-infrared Spectroscopy Measurements
    Kolkhorst, Fred W.
    Hom, Clifford
    Lopez, Jon M.
    Pozos, Robert E.
    Buono, Michael J.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S168 - S169
  • [5] Assessing functional sympatholysis during rhythmic handgrip exercise using Doppler ultrasound and near-infrared spectroscopy: sex differences and test-retest reliability
    Teixeira, Andre L.
    Garland, Matthew
    Lee, Jordan B.
    Nardone, Massimo
    Millar, Philip J.
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY, INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2022, 323 (05) : R810 - R821
  • [6] Analysis of brain oxygenation using near-infrared reflection spectroscopy and correlation to laser doppler flow
    Goetz, AE
    Kuebler, WM
    Plesnila, N
    Rinecker, M
    Peter, K
    [J]. ANESTHESIOLOGY, 1998, 89 (3A) : U408 - U408
  • [7] Near-infrared spectroscopy measures of sternocleidomastoid blood flow during exercise and hyperpnoea
    Ramsook, Andrew H.
    Peters, Carli M.
    Leahy, Michael G.
    Archiza, Bruno
    Mitchell, Reid A.
    Jasinovic, Tin
    Koehle, Michael S.
    Guenette, Jordan A.
    Sheel, A. William
    [J]. EXPERIMENTAL PHYSIOLOGY, 2020, 105 (12) : 2226 - 2237
  • [8] Near-infrared Spectroscopy Measures Of Sternocleidomastoid Blood Flow During Exercise And Hyperpnea
    Ramsook, Andrew H.
    Peters, Carli M.
    Leahy, Michael G.
    Archiza, Bruno
    Mitchell, Reid A.
    Jasinovic, Tin
    Koehle, Michael S.
    Guenette, Jordan A.
    Sheel, A. William
    [J]. MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 394 - 395
  • [9] Laser Doppler perfusion imaging of skin blood flow using red and near-infrared sources
    Abbot, NC
    Ferrell, WR
    Lockhart, JC
    Lowe, JG
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1996, 107 (06) : 882 - 886
  • [10] Short-time effects of laser needle stimulation on the peripheral microcirculation assessed by laser Doppler spectroscopy and near-infrared spectroscopy
    Banzer, Winfried
    Huebscher, Markus
    Seib, Miriam
    Vogt, Lutz
    [J]. PHOTOMEDICINE AND LASER SURGERY, 2006, 24 (05) : 575 - 580