Proportional quartz-glass counter for detecting external X-rays

被引:0
|
作者
Kuzminov, VV
Yants, VE
机构
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The described counter incorporates a cathode of pyrolytic graphite and a similar to 0.15-mm-thick entrance window with similar to 5-cm(2) area. The counter service life, being defined by a change of 1% in the gas-amplification coefficient M, exceeds 1.1 x 10(-3) C/cm (i.e., 1.5 x 10(10) pulses/cm for 22.2-keV X-rays at M = 447). In the -50 to +120 degrees C temperature range, the value of M and energy resolution are virtually constant. The resolution of the 22.2-keV X-ray line is 7.3% for a 100-s(-1) count rate.
引用
收藏
页码:427 / 428
页数:2
相关论文
共 50 条
  • [1] MINIATURE PROPORTIONAL COUNTER WITH QUARTZ-GLASS HOUSING
    KUZMINOV, VV
    LIKHOVID, NA
    NOVIKOV, VM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1990, 33 (04) : 806 - 807
  • [2] WINDOWLESS PROPORTIONAL COUNTER FOR SOFT X-RAYS
    KIFUNE, T
    KAWASHIMA, N
    NUCLEAR INSTRUMENTS & METHODS, 1972, 103 (01): : 167 - +
  • [3] ELECTRONIC APPARATUS FOR THE STUDY OF X-RAYS WITH PROPORTIONAL COUNTER
    PATLA, N
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1960, 37 (10): : 388 - 393
  • [4] The reflection of X-rays from glass and quartz
    Laby, TH
    Shearer, J
    Bingham, R
    NATURE, 1928, 122 : 96 - 97
  • [5] MEASUREMENT OF THE QUANTUM EFFICIENCY OF A PROPORTIONAL COUNTER USING X-RAYS
    KISS, AE
    PATLA, N
    BRITISH JOURNAL OF APPLIED PHYSICS, 1959, 10 (08): : 376 - 380
  • [6] A COMPACT GAS SCINTILLATION PROPORTIONAL COUNTER FOR ULTRASOFT X-RAYS
    MAEYAMA, S
    SUGIYAMA, M
    OSHIMA, M
    SHIMIZU, K
    SHOJI, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (05): : 1229 - 1231
  • [7] PROPORTIONAL COUNTER MEASUREMENTS OF PI-MESONIC X-RAYS
    WEST, D
    BRADLEY, EF
    PHILOSOPHICAL MAGAZINE, 1957, 2 (20): : 957 - 976
  • [8] BACKGROUND SUPPRESSION IN A GAS SCINTILLATION PROPORTIONAL COUNTER FOR EXOTIC X-RAYS
    OKX, WJC
    VANEIJK, CWE
    MARQUES, RF
    HOLLANDER, RW
    LANGERVELD, D
    ZOUTENDIJK, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (2-3): : 605 - 608
  • [9] DETECTION OF SOFT X-RAYS WITH A XENON PROPORTIONAL SCINTILLATION-COUNTER
    POLICARPO, AJ
    ALVES, MAF
    SALETE, M
    LEITE, SCP
    DOSSANTO.MC
    NUCLEAR INSTRUMENTS & METHODS, 1974, 118 (01): : 221 - 226
  • [10] DOUBLE PROPORTIONAL COUNTER FOR MEASUREMENT OF RADIOISOTOPE AUGER ELECTRONS AND X-RAYS
    MORI, C
    NOGUCHI, H
    ISHIGURE, N
    FUJITA, K
    WATANABE, T
    NUCLEAR INSTRUMENTS & METHODS, 1979, 164 (01): : 113 - 120