Initial arch wires used in orthodontic treatment with fixed appliances

被引:23
|
作者
Wang, Yan [1 ]
Liu, Chang [2 ]
Jian, Fan [1 ]
McIntyre, Grant T. [3 ]
Millett, Declan T. [4 ]
Hickman, Joy [5 ]
Lai, Wenli [1 ]
机构
[1] Sichuan Univ, Dept Orthodont, State Key Lab Oral Dis, West China Hosp Stomatol, 14,Sect 3,Ren Min Nan Rd, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, Dept Oral & Maxillofacial Surg, State Key Lab Oral Dis, West China Hosp Stomatol, Chengdu, Sichuan, Peoples R China
[3] Univ Dundee, Sch Dent, Dundee, Scotland
[4] Cork Univ, Dent Sch & Hosp, Oral Hlth & Dev, Cork, Ireland
[5] Glan Clwyd Gen Hosp, Dept Orthodont, Rhyl, Wales
关键词
Dental Alloys; Orthodontic Brackets [standards; Orthodontic Wires [adverse effects; standards; Randomized Controlled Trials as Topic; Root Resorption [etiology; Tooth Movement Techniques [adverse effects; instrumentation; Toothache [etiology; Humans; RANDOMIZED CLINICAL-TRIAL; NICKEL-TITANIUM ALLOYS; ALIGNMENT EFFICIENCY; STAINLESS-STEEL; PAIN PERCEPTION; TOOTH MOVEMENT; ARCHWIRES; DISCOMFORT; PLACEMENT; INDEX;
D O I
10.1002/14651858.CD007859.pub4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Initial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of teeth by correcting crowding and rotations. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause least amount of root resorption and pain during the initial aligning stage of treatment. This is an update of the review entitled Initial arch wires for alignment of crooked teeth with fixed orthodontic braces, which was first published in 2010. Objectives To assess the effects of initial arch wires for the alignment of teeth with fixed orthodontic braces, in terms of the rate of tooth alignment, amount of root resorption accompanying tooth movement, and intensity of pain experienced by patients during the initial alignment stage of treatment. Search methods Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 5 October 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, 2017, Issue 9), MEDLINE Ovid (1946 to 5 October 2017), and Embase Ovid (1980 to 5 October 2017. The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. Selection criteria We included randomised controlled trials (RCTs) of initial arch wires to align teeth with fixed orthodontic braces. We included only studies involving participants with upper or lower, or both, full arch fixed orthodontic appliances. Data collection and analysis Two review authors were responsible for study selection, 'Risk of bias' assessment and data extraction. We resolved disagreements by discussion between the review authors. We contacted corresponding authors of included studies to obtain missing information. We assessed the quality of the evidence for each comparison and outcome as high, moderate, low or very low, according to GRADE criteria. Main results For this update, we found three new RCTs (228 participants), bringing the total to 12 RCTs with 799 participants. We judged three studies to be at high risk of bias, and three to be at low risk of bias; six were unclear. None of the studies reported the adverse outcome of root resorption. The review assessed six comparisons. 1. Multistrand stainless steel versus superelastic nickel-titanium (NiTi) arch wires. There were five studies in this group and it was appropriate to undertake a meta-analysis of two of them. There is insufficient evidence from these studies to determine whether there is a difference in rate of alignment between multistrand stainless steel and superelastic NiTi arch wires (mean difference (MD) -7.5 mm per month, 95% confidence interval (CI) -26.27 to 11.27; 1 study, 48 participants; low-quality evidence). The findings for pain at day 1 as measured on a 100 mm visual analogue scale suggested that there was no meaningful difference between the interventions (MD -2.68 mm, 95% CI -6.75 to 1.38; 2 studies, 127 participants; moderate-quality evidence). 2. Multistrand stainless steel versus thermoelastic NiTi arch wires. There were two studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from the studies to determine whether there is a difference in rate of alignment between multistrand stainless steel and thermoelastic NiTi arch wires (low-quality evidence). Pain was not measured. 3. Conventional NiTi versus superelastic NiTi arch wires. There were three studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is any difference between conventional and superelastic NiTi arch wires with regard to either alignment or pain (low-to very low-quality evidence). 4. Conventional NiTi versus thermoelastic NiTi arch wires. There were two studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is a difference in alignment between conventional and thermoelastic NiTi arch wires (low-quality evidence). Pain was not measured. 5. Single-strand superelastic NiTi versus coaxial superelastic NiTi arch wires. There was only one study (24 participants) in this group. There is moderate-quality evidence that coaxial superelastic NiTi can produce greater tooth movement over 12 weeks (MD -6.76 mm, 95% CI -7.98 to -5.55). Pain was not measured. 6. Superelastic NiTi versus thermoelastic NiTi arch wires. There were three studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is a difference in alignment or pain between superelastic and thermoelastic NiTi arch wires (low-quality evidence). Authors' conclusions Moderate-quality evidence shows that arch wires of coaxial superelastic nickel-titanium(NiTi) can produce greater tooth movement over 12 weeks than arch wires made of single-strand superelastic NiTi. Moderate-quality evidence also suggests there may be no difference in pain at day 1 between multistrand stainless steel arch wires and superelastic NiTi arch wires. Other than these findings, there is insufficient evidence to determine whether any particular arch wire material is superior to any other in terms of alignment rate, time to alignment, pain and root resorption.
引用
收藏
页数:77
相关论文
共 50 条
  • [1] Initial arch wires for tooth alignment during orthodontic treatment with fixed appliances
    Jian, Fan
    Lai, Wenli
    Furness, Susan
    McIntyre, Grant T.
    Millett, Declan T.
    Hickman, Joy
    Wang, Yan
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2013, (04):
  • [2] Initial arch wires for alignment of crooked teeth with fixed orthodontic braces
    Wang, Yan
    Jian, Fan
    Lai, Wenli
    Zhao, Zhihe
    Yang, Zhi
    Liao, Zhengyu
    Shi, Zongdao
    Wu, Taixiang
    Millett, Declan T.
    McIntyre, Grant T.
    Hickman, Joy
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2010, (04):
  • [3] Accuracy of dental arch form in customized fixed labial orthodontic appliances
    Wang, Xiaoting
    Xia, Lunguo
    Li, Jiayi
    Li, Lvyuan
    Yu, Fei
    Yuan, Lingjun
    Fang, Bing
    Ye, Niansong
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 162 (02) : 173 - 181
  • [4] Evaluation and Comparison of Load Deflection Rate of Four Arch Wires Used in The Alignment Phase of Fixed Orthodontic Treatment: An In-Vitro Study
    Choudary, D.
    Jnaneshwar, P. R.
    Kannan, R.
    [J]. INTERNATIONAL JOURNAL OF ORTHODONTIC REHABILITATION, 2022, 13 (03)
  • [5] Insufficient evidence available to reliably conclude how orthodontic treatment with lingual fixed appliances compares with orthodontic treatment with labial fixed appliances
    Brignardello-Petersen, Romina
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2018, 149 (05): : E81 - E81
  • [6] Methods used for prevention of white spot lesion development during orthodontic treatment with fixed appliances
    Kerbusch, Antoine E. G.
    Kuijpers-Jagtman, Anne M.
    Mulder, Jan
    van der Sanden, Wil J. M.
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 2012, 70 (06) : 564 - 568
  • [7] Pain Perception during Orthodontic Treatment with Fixed Appliances
    Olteanu, Cristian Doru
    Bucur, Sorana-Maria
    Chibelean, Manuela
    Bud, Eugen Silviu
    Pacurar, Mariana
    Festila, Dana Gabriela
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (13):
  • [8] ASSESSING TREATMENT EFFECTIVENESS OF REMOVABLE AND FIXED ORTHODONTIC APPLIANCES
    TANG, ELK
    WEI, SHY
    [J]. JOURNAL OF DENTAL RESEARCH, 1990, 69 : 172 - 172
  • [10] Perception of pain during orthodontic treatment with fixed appliances
    Erdinç, AME
    Dinçer, B
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2004, 26 (01) : 79 - 85