Non-rigid alignment of pre-operative MRI, fMRI, and DT-MRI with intra-operative MRI for enhanced visualization and navigation in image-guided neurosurgery

被引:117
|
作者
Archip, Neculal
Clatz, Olivier
Whalen, Stephen
Kacher, Dan
Fedorov, Andriy
Kot, Andriy
Chrisocholdes, Nikos
Jolesz, Ferenc
Golby, Alexandra
Black, Peter M.
Warfield, Simon K.
机构
[1] Harvard Univ, Sch Med, Dept Radiol, Brigham & Womens Hosp, Boston, MA 02115 USA
[2] Childrens Hosp, Dept Radiol, Computat Radiol Lab, Boston, MA 02115 USA
[3] Coll William & Mary, Dept Comp Sci, Williamsburg, VA 23185 USA
[4] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Neurosurg, Boston, MA 02115 USA
关键词
MRI; DT-MRI; fMRI; brain; image-guided neurosurgery; navigation systems; non-rigid registration;
D O I
10.1016/j.neuroimage.2006.11.060
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objective: The usefulness of neurosurgical navigation with current visualizations is seriously compromised by brain shift, which inevitably occurs during the course of the operation, significantly degrading the precise alignment between the pre-operative MR data and the intraoperative shape of the brain. Our objectives were (i) to evaluate the feasibilitv of non-rigid registration that compensates for the brain deformations within the time constraints imposed by neurosurgery, and (ii) to create augmented reality visualizations of critical structural and functional brain regions during neurosurgery using pre-operatively acquired fMRI and DT-MRI. Materials and methods: Eleven consecutive patients with supratentorial gliomas were included in our study. All underwent surgery at our intraoperative MR imaging-guided therapy facility and have tumors in eloquent brain areas (e.g. precentral gyrus and cortico-spinal tract). Functional MRI and DT-MRI, together with MPRAGE and T2w structural MRI were acquired at 3 T prior to surgery. SPGR and T2w images were acquired with a 0.5 T magnet during each procedure. Quantitative assessment of the alignment accuracy was carried out and compared with current state-of-the-art systems based only on rigid registration. Results: Alignment between pre-operative and intra-operative datasets was successfully carried out during surgery for all patients. Overall, the mean residual displacement remaining after non-rigid registration was 1.82 rum. There is a statistically significant improvement in alignment accuracy utilizing our non-rigid registration in comparison to the currently used technology (p < 0.001). Conclusions: We were able to achieve intra-operative rigid and nonrigid registration of (1) pre-operative structural MRI with intraoperative T1w NMRI; (2) pre-operative fMRI with intra-operative T1w MRI, and (3) pre-operative DT-MRI with intra-operative T1w MRI. The registration algorithms as implemented were sufficiently robust and rapid to meet the hard real-time constraints of intra-operative surgical decision making. The validation experiments demonstrate that we can accurately compensate for the deformation of the brain and thus can construct an augmented reality visualization to aid the surgeon. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:609 / 624
页数:16
相关论文
共 19 条
  • [1] Curvelet Based Residual Complexity Objective Function for Non-rigid Registration of Pre-operative MRI with Intra-operative Ultrasound Images
    Farnia, P.
    Makkiabadi, B.
    Ahmadian, A.
    Alirezaie, J.
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 1167 - 1170
  • [2] Correlation of intra-operative hamstring autograft size with pre-operative anthropometric and MRI measurements
    Corey, Sally
    Mueller, Terry
    Hartness, Christopher
    Prasad, Balakrishna M.
    [J]. JOURNAL OF ORTHOPAEDICS, 2018, 15 (04) : 988 - 991
  • [3] Augment low-field intra-operative MRI with preoperative MRI using a hybrid non-rigid registration method
    Yao, Chengjun
    Liu, Yixun
    Yao, Jianhua
    Zhuang, Dongxiao
    Wu, Jinsong
    Qin, Zhiyong
    Mao, Ying
    Zhou, Liangfu
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2014, 117 (02) : 114 - 124
  • [4] Integration of intra-operative 3D ultrasound with pre-operative MRI for neurosurgical guidance
    Gobbi, DG
    Comeau, RM
    Lee, BKH
    Peters, TM
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1738 - 1740
  • [5] A hybrid method for Non-rigid registration of Intra-operative Ultrasound Images with pre-operative MR images
    Farnia, P.
    Ahmadian, A.
    Shabanian, T.
    Serej, N. D.
    Alirezaie, J.
    [J]. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 5562 - 5565
  • [6] Comparison between pre-operative MRI and intra-operative endoscopic findings for idiopathic normal pressure hydrocephalus
    Daisuke Kita
    Yasuhiko Hayashi
    Issei Fukui
    Masahiro Oishi
    Cheho Park
    Mitsutoshi Nakada
    [J]. Fluids and Barriers of the CNS, 12 (Suppl 1)
  • [7] Utilization of pre-operative MRI to identify AIS patients at highest risk of intra-operative neuromonitoring alert
    Sassan Keshavarzi
    Subaraman Ramchandran
    Jeffrey Spardy
    Alyssa Dobyns
    Thomas Errico
    Stephen George
    [J]. Spine Deformity, 2023, 11 : 1419 - 1426
  • [8] Utilization of pre-operative MRI to identify AIS patients at highest risk of intra-operative neuromonitoring alert
    Keshavarzi, Sassan
    Ramchandran, Subaraman
    Spardy, Jeffrey
    Dobyns, Alyssa
    Errico, Thomas
    George, Stephen
    [J]. SPINE DEFORMITY, 2023, 11 (06) : 1419 - 1426
  • [9] Guidance of Intra-Operative Ventricular Tachycardia Ablation during LVAD Implantation with Pre-operative Cardiac MRI
    Al-Saffar, Farah
    Ibrahim, Saif
    Dailey, Caroline
    Scott, Robert
    Jahanyar, Jama
    Mulpuru, Siva
    [J]. JOURNAL OF CARDIAC FAILURE, 2018, 24 (08) : S63 - S64
  • [10] Correlation of pre-operative MRI and intra-operative 3D ultrasound to measure brain tissue shift
    Gobbi, DG
    Comeau, RM
    Lee, BKH
    Peters, TM
    [J]. MEDICAL IMAGING 2000: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2000, 3982 : 77 - 84