Evaluation of a novel ambulatory electrocardiogram monitor (the Carnation Ambulatory Monitor) for use in horses

被引:4
|
作者
Keen, J. A. [1 ,2 ]
O'Connor, S. A. [3 ]
机构
[1] Univ Edinburgh, Equine Hosp, Royal Dick Sch Vet Studies, Dept Vet Clin Studies, Easter Bush Campus, Roslin EH25 9RG, Midlothian, Scotland
[2] Univ Edinburgh, Roslin Inst, Easter Bush Campus, Roslin EH25 9RG, Midlothian, Scotland
[3] City Univ London, Dept Bioengn, Northampton Sq, London ECV 0HB, England
关键词
Equine; Electrocardiogram; Holter; Arrhythmia;
D O I
10.1016/j.jvc.2020.12.005
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Introduction: Short-term electrocardiogram (ECG) examinations of horses may not detect paroxysmal arrhythmias. Twenty-four hour Holter equipment can be unwieldy and inconvenient for long-term use. This study evaluated a novel long-term ECG patch recorder, the Carnation Ambulatory Monitor (CAM) in horses, determining ideal placement, practicality, durability and performance. Animals: Twenty-one adult mixed-breed horses. Methods: Prospective observational study. Three horses had ECG patches fitted at selected sites (phase 1); the two most promising sites were used for further wear testing (phase 2) and the best site was chosen for a trial in 18 horses (phase 3), 16 of which had presented for evaluation of cardiac disease. In phase 1, the CAM was compared with a standard telemetric ECG. The CAM ECGs were analysed using proprietary software. Results: The most promising sites for CAM placement were the ventral midline caudal to the xiphisternum and left thorax caudal to the girth. The ventral midline was chosen for further evaluation. The CAM provided reliable and generally excellent ECG quality at rest (median quality score 4.5/5, range 3-5), over extended periods, allowing detection of arrhythmias. The ECG quality was poor during exercise (median quality score 1, range 1-5), except in three horses. In 15/17 placements in the standing horse, greater than 85% of the potential recording time was achieved. Conclusions: The CAM is a convenient and well-tolerated device for evaluating equine cardiac rhythm at rest over long periods. Further evaluation of the ideal placement site during exercise may increase its diagnostic utility. & ordf; 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 28
页数:13
相关论文
共 50 条
  • [1] Early experience with a novel ambulatory monitor
    Russell, James K.
    Gehman, Stacy
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2007, 40 (06) : S160 - S164
  • [2] An ambulatory dyskinesia monitor
    Manson, AJ
    Brown, P
    O'Sullivan, JD
    Asselman, P
    Buckwell, D
    Lees, AJ
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2000, 68 (02): : 196 - 201
  • [3] THE AMBULATORY RENAL MONITOR
    PETERS, AM
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (12) : 2276 - 2277
  • [4] Use of Wheeze Monitor Device in the Ambulatory Setting
    Tan, Ricardo A.
    Spector, Sheldon L.
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2015, 135 (02) : AB245 - AB245
  • [5] Using an ambulatory electrocardiogram monitor to record skin sympathetic nerve activity
    Liu, Xiao
    Rosenberg, Carine
    Ricafrente, Joselyn
    Leier, Mary E.
    Dinh, Harrison
    Everett, Thomas H.
    Chen, Peng-Sheng
    [J]. HEART RHYTHM, 2022, 19 (02) : 330 - 331
  • [6] THE AMBULATORY RENAL MONITOR - REPLY
    RABITO, CA
    MOORE, RH
    BOUGAS, C
    DRAGOTAKES, SC
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (12) : 2277 - 2277
  • [7] Clinical impact of a novel ambulatory rhythm monitor in children
    May, Joseph W.
    Carter, Elizabeth L.
    Hitt, J. Ryan
    Burklow, Thomas R.
    [J]. CARDIOLOGY IN THE YOUNG, 2018, 28 (10) : 1134 - 1140
  • [8] An ambulatory fall monitor for the elderly
    Tamura, T
    Yoshimura, T
    Horiuchi, F
    Higashi, Y
    Fujimoto, T
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2608 - 2610
  • [9] Ambulatory Function Monitor for Amputees
    Ooi, S. N.
    Abu Osman, N. A.
    [J]. 5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 732 - 734
  • [10] Evaluation of actitrac (ambulatory activity monitor) in idiopathic parkinsonism
    Ruiz, P. J. Garcia
    [J]. MOVEMENT DISORDERS, 2006, 21 : S457 - S457